Furuno FSV-30S Installing the Attachment Kit option, Attachment kit Type OP10-24, Code no

Page 21

1.8 Installing the Attachment Kit (option)

The attachment kit permits use of the tank for the CSH-20 series using the 1600 mm stroke transducer and FSV-243E/244E.

Attachment kit (Type: OP10-24, Code no.: 006-943-530)

Name

Type

Code No.

Qty

Insulation gasket (1)

MS-1000-67

000-857-220

24

Insulation gasket (2)

MS-1000-68

000-857-221

24

1.Clean the hull unit flange, the O-ring and O-ring groove. Coat them with a slight amount of grease. Place the O-ring in position on the tank flange.

2.Lay the insulation gasket (1) on the top of the tank flange.

3.Orient the hull unit so that the bow mark (inscribed) on its flange points toward the ship’s bow. Note that heading adjustment in the monitor is required if the bow mark does not face the ship’s bow.

4.Confirm that the O-ring and the insulation gasket (1) are in position.

5.Place the hull unit on the tank.

6.Seven of the 24 bolt holes on the hull unit flange have already been fitted with bolts (stern side). Insert the insulation gasket (2) into the bolt holes of the tank flange to which these seven bolts are fitted.

7.Coat every bolt, washer and nut with a slight amount of grease to ease removal. Fit the insulation gasket (2) into the bolt holes of the tank flange. Fasten the hull unit to the retraction tank with insulation gasket (2), flat washers, spring washers and hex bolts.

8.Reinforce the hull unit against vibration by extending stays to the ship’s hull from the two eye bolts at the top of the hull unit, referring to the figure at the top of page 1-8.

1-15

Image 21
Contents Color Scanning Sonar 00014857415 Safety Instructions Projected Raising Lowering Mm stroke Max kt Iii System ConfigurationOptional Equipment Standard supplyHull Unit Mounting considerationsHull unit mounting location Maintenance space, example sonar compartment Guidelines for shortening the retraction tank Shortening the retraction tankHow to install reinforcement ribs Remarks for installation of retraction tankInstalling hull unit on retraction tank Installation of hull unit Installing stays anti-vibration measure Proper installation of staysProper and improper stay installation methods Processor Unit Mounting considerationsProcessor unit, rear view Control Unit Mounting procedureProcessor unit Rubber feetMounting without KB fixing plate How to attach KB fixing plateControl unit Mounting with KB fixing plateControl unit, side view Control unit, cover removedGrounding the Equipment Transceiver UnitTransceiver unit Transceiver unit, junction box Use copper strap suppliedInstalling the Attachment Flange option ProcedureAttachment flange Type OP10-27, Code no Junction box Cable Extension Kit optionAttachment kit Type OP10-24, Code no Installing the Attachment Kit optionInstallation of attachment kit How to use the crimping tool How to Use the Crimping Tool, Pin ExtractorHow to use the pin extractor Crimping tool, contact pin, pin extractorWiring WiringTransceiver unit side Cable type 10S1258-1, sectional view 1 10S1258-1 cableFabrication of cable for connector 00-8016-038-313761HV Fabrication of connector 00-8016-038-313761HV CN-A101Assembling 38P connector Positioning guide pinsPower cable Assembling connector NCS-253-PControl cable Sectional view of cables Cable listGyro Synchronizing with echo sounder or other sonar Menu settingFor current driven KP input For voltage driven KP 12 V inputFabrication of cable for 00-8016-038-313761HV Fabrication of connector 00-8016-038-313761HV CN-B101CN-B101 CN-B102 Transceiver unit, inside viewFabrication of power cable type DPYCYS-2.5 TB-B101 Hull control cable 10S2078Fabrication of cable type DPYCYS-2.5 Transceiver unit, top view Wiring in transceiver unitCable Extension Kit Junction boxJunction box, cover removed Signal cable 10S2240 connects to Junction BOX display side Raise/lower control box, cover removed Raise/Lower control boxPower cable fabrication Input voltage Input Voltage and FusesFuses Marking the labelHull Unit Check Main menuOthers menu Test menu Initial Setting menuHow to check the hull unit Transducer switches of the control unitControl unit in hull unit Page Heading Adjustment Heading adjustmentSystem menu Others menu, Heading Adjust Configuring Own Ship Mark OWN Ship Mark menu, setting windowOWN Ship Mark menu Ship shape description Interface Setting menu Interface Setting menuOther System Menu Items EXT Data Setting menu EXT Data Setting menuData sentences Nmea 0183, Furuno proprietary ES Draft Offset Others menuCone Board Setting in the Processor Unit Adjustment of signal level echo sounder connectedAdjusting the volume of the audio alarm 1 CIF2/NMEA2 connector interface selection DIP Switch SettingProcessor unit, inside view Ifes Board 10P6983Choosing echosounder signal This page intentionally left blank Processor unit, front view Name Type Code No Qty RemarksGND Wiring between processor unit and CS-120ADcon Board 10P6984 or 10P6984A This page intentionally left blank Packing List FSV-301 58 58 58 58 58 付属品表 52#42#465.+5614 52 Page Page Page Hatai Hatai Hatai Hatai Hatai Page Page This page is intentionally left blank Color Scanning Sonar Miyosi