Furuno FSV-30 Cone Board Setting in the Processor Unit, Adjusting the volume of the audio alarm

Page 53

TRACKBALL SPEED

Choose the speed of trackball movement (inside menu window only). (SLOW, NORMAL, FAST)

HULL UNIT STROKE

Choose the stroke length of the hull unit. (1200 mm, 1600 mm).

3.5 CONE Board Setting in the Processor Unit

Adjust the potentiometers on the CONE Board in the processor unit, referring to the table shown below.

Location

Name

Resistance

Function

No.

 

value

 

R118

ALARM

10 kΩ

Adjust the volume of audio

 

 

 

alarm.

R119

ES2_OFF

1 kΩ

Adjust ES2 signal offset.

 

 

 

 

R167

ES2_GAIN

10 kΩ

Adjust ES2 signal gain.

 

 

 

 

R168

ES1_OFF

1 kΩ

Adjust ES1 signal offset.

 

 

 

 

R209

ES1_GAIN

10 kΩ

Adjust ES1 signal gain.

 

 

 

 

Adjustment

CW: Large

CCW: Small

CW: Noise decrease

CCW: Noise increase

CW: Gain increase

CCW: Gain decrease

CW: Noise decrease

CCW: Noise increase

CW: Gain increase

CCW: Gain decrease

3.5.1 Adjustment of signal level (echo sounder connected)

Adjusts the output level of the echo sounder on the CONE Board as below.

1.Choose an echo sounder display (ES1 or ES2) from the menu.

2.For ES1, adjust R168 to suppress noise, and then adjust R209 so that the picture condition is similar to that of connected echo sounder connected to the FSV-30.

3.For ES 2, adjust R119 to suppress noise, and then adjust R167 so that the picture condition is similar to that of echo sounder connected to the FSV-30.

3.5.2 Adjusting the volume of the audio alarm

The volume of the audio alarm cannot be adjusted from the control unit. If necessary, adjust R118 on the CONE Board to choose appropriate volume.

3-13

Image 53
Contents Color Scanning Sonar 00014857415 Safety Instructions Projected Raising Lowering Mm stroke Max kt Iii System ConfigurationOptional Equipment Standard supplyHull unit mounting location Hull UnitMounting considerations Maintenance space, example sonar compartment Guidelines for shortening the retraction tank Shortening the retraction tankHow to install reinforcement ribs Remarks for installation of retraction tankInstalling hull unit on retraction tank Installation of hull unit Proper and improper stay installation methods Installing stays anti-vibration measureProper installation of stays Processor unit, rear view Processor UnitMounting considerations Control Unit Mounting procedureProcessor unit Rubber feetMounting without KB fixing plate How to attach KB fixing plateControl unit Mounting with KB fixing plateControl unit, side view Control unit, cover removedGrounding the Equipment Transceiver UnitTransceiver unit Transceiver unit, junction box Use copper strap suppliedAttachment flange Type OP10-27, Code no Installing the Attachment Flange optionProcedure Junction box Cable Extension Kit optionAttachment kit Type OP10-24, Code no Installing the Attachment Kit optionInstallation of attachment kit How to use the crimping tool How to Use the Crimping Tool, Pin ExtractorHow to use the pin extractor Crimping tool, contact pin, pin extractorWiring WiringTransceiver unit side Cable type 10S1258-1, sectional view 1 10S1258-1 cableFabrication of cable for connector 00-8016-038-313761HV Fabrication of connector 00-8016-038-313761HV CN-A101Assembling 38P connector Positioning guide pinsControl cable Power cableAssembling connector NCS-253-P Sectional view of cables Cable listGyro Synchronizing with echo sounder or other sonar Menu settingFor current driven KP input For voltage driven KP 12 V inputFabrication of cable for 00-8016-038-313761HV Fabrication of connector 00-8016-038-313761HV CN-B101CN-B101 CN-B102 Transceiver unit, inside viewFabrication of cable type DPYCYS-2.5 Fabrication of power cable type DPYCYS-2.5 TB-B101Hull control cable 10S2078 Transceiver unit, top view Wiring in transceiver unitJunction box, cover removed Cable Extension KitJunction box Signal cable 10S2240 connects to Junction BOX display side Raise/lower control box, cover removed Raise/Lower control boxPower cable fabrication Input voltage Input Voltage and FusesFuses Marking the labelOthers menu Hull Unit CheckMain menu Test menu Initial Setting menuControl unit in hull unit How to check the hull unitTransducer switches of the control unit Page System menu Heading AdjustmentHeading adjustment Others menu, Heading Adjust OWN Ship Mark menu Configuring Own Ship MarkOWN Ship Mark menu, setting window Ship shape description Other System Menu Items Interface Setting menuInterface Setting menu EXT Data Setting menu EXT Data Setting menuData sentences Nmea 0183, Furuno proprietary ES Draft Offset Others menuAdjusting the volume of the audio alarm Cone Board Setting in the Processor UnitAdjustment of signal level echo sounder connected 1 CIF2/NMEA2 connector interface selection DIP Switch SettingProcessor unit, inside view Ifes Board 10P6983Choosing echosounder signal This page intentionally left blank Processor unit, front view Name Type Code No Qty RemarksGND Wiring between processor unit and CS-120ADcon Board 10P6984 or 10P6984A This page intentionally left blank Packing List FSV-301 58 58 58 58 58 付属品表 52#42#465.+5614 52 Page Page Page Hatai Hatai Hatai Hatai Hatai Page Page This page is intentionally left blank Color Scanning Sonar Miyosi