Furuno FSV-30S installation manual Standard supply, Optional Equipment

Page 6

EQUIPMENT LISTS

Standard supply

Name

Type

Code No.

Qty

Remarks

Control Unit

FSV-3001

1

With cable

Processor Unit

FSV-3002

1

For FSV-30

 

 

 

FSV-3002S

For FSV-30S

 

 

Transceiver Unit

FSV-301

1

 

Hull Unit

FSV-303/303-R

1

1200 mm stroke

FSV-304/304-R

1600 mm stroke

 

 

 

 

 

 

Signal cable 10S2078

 

CP10-06000

000-144-389

1 set

(between transceiver unit and

 

 

 

 

hull unit, 8 m)

Installation Materials

CP10-06201

007-008-540

1 set

For transceiver unit. See

packing list.

 

 

 

 

 

CP10-06100

000-067-067

1 set

For processor unit

 

 

CP10-04502, CP10-04506.

 

 

 

 

See packing list.

 

SP10-03101

007-008-530

1 set

For transceiver unit. See

 

packing list.

 

 

 

 

Spare Parts

SP10-02601

006-921-340

1 set

For processor unit. See

 

packing list.

 

 

 

 

 

SP10-02603

006-921-360

1 set

For processor unit

Accessories

FP10-02901

007-008-780

1 set

For processor unit

FP10-02201

006-922-390

1 set

For control unit

 

Optional Equipment

Name

Type

Code No.

Qty

Remarks

Control Unit

FSV-3001

1

 

37-core Cable

10S1258

001-113-000-10

1

Specify length

E/S Interface

VI-1100A

1

 

Net Sonde

CS-170

1

 

Junction Box

 

 

 

 

Power Supply Kit

FSV-2403

000-067-013

1

For connection of CS-120A

NMEA Cable

MJ-A6SPF0012-100C

000-154-037-10

1

10 m, NMEA, 6P-6P

 

MJ-A6SPF0012-050C

000-154-053-10

1

5 m, NMEA, 6P-6P

8-core Cable

VVS 0.38C *6M*

000-555-043

1

6 m, for echosounder, 02S8040

Attachment

OP10-27

000-067-050

1

 

Flange

 

 

 

 

 

Attachment Kit

OP10-24

006-943-530

 

 

Loudspeaker

SEM-21Q

000-144-917

1

 

Installation

CP10-04801

006-934-240

1

See back of manual for details.

Materials

 

 

 

 

 

Cable Extension

FSV-305-5

000-067-072

1

Junction box, 10S2240, 10S2144

Kit

FSV-305-15

000-067-073

Junction box, 10S2240, 10S2145

 

Data Recording

OP10-31

000-017-095

1

 

Kit

 

 

 

 

 

Calibration Ball

OP10-33

000-017-096

1

φ38.1

 

OP10-34

000-017-097

1

φ47.625

iv

Image 6
Contents Color Scanning Sonar 00014857415 Safety Instructions Projected Raising Lowering Mm stroke Max kt System Configuration IiiStandard supply Optional EquipmentHull Unit Mounting considerationsHull unit mounting location Maintenance space, example sonar compartment Shortening the retraction tank Guidelines for shortening the retraction tankRemarks for installation of retraction tank How to install reinforcement ribsInstalling hull unit on retraction tank Installation of hull unit Installing stays anti-vibration measure Proper installation of staysProper and improper stay installation methods Processor Unit Mounting considerationsProcessor unit, rear view Processor unit Mounting procedureControl Unit Rubber feetControl unit How to attach KB fixing plateMounting without KB fixing plate Mounting with KB fixing plateControl unit, cover removed Control unit, side viewTransceiver unit Transceiver UnitGrounding the Equipment Transceiver unit, junction box Use copper strap suppliedInstalling the Attachment Flange option ProcedureAttachment flange Type OP10-27, Code no Cable Extension Kit option Junction boxInstalling the Attachment Kit option Attachment kit Type OP10-24, Code noInstallation of attachment kit How to use the pin extractor How to Use the Crimping Tool, Pin ExtractorHow to use the crimping tool Crimping tool, contact pin, pin extractorWiring WiringTransceiver unit side 1 10S1258-1 cable Cable type 10S1258-1, sectional viewAssembling 38P connector Fabrication of connector 00-8016-038-313761HV CN-A101Fabrication of cable for connector 00-8016-038-313761HV Positioning guide pinsPower cable Assembling connector NCS-253-PControl cable Cable list Sectional view of cablesGyro For current driven KP input Menu settingSynchronizing with echo sounder or other sonar For voltage driven KP 12 V inputFabrication of connector 00-8016-038-313761HV CN-B101 Fabrication of cable for 00-8016-038-313761HVTransceiver unit, inside view CN-B101 CN-B102Fabrication of power cable type DPYCYS-2.5 TB-B101 Hull control cable 10S2078Fabrication of cable type DPYCYS-2.5 Wiring in transceiver unit Transceiver unit, top viewCable Extension Kit Junction boxJunction box, cover removed Signal cable 10S2240 connects to Junction BOX display side Raise/Lower control box Raise/lower control box, cover removedPower cable fabrication Fuses Input Voltage and FusesInput voltage Marking the labelHull Unit Check Main menuOthers menu Initial Setting menu Test menuHow to check the hull unit Transducer switches of the control unitControl unit in hull unit Page Heading Adjustment Heading adjustmentSystem menu Others menu, Heading Adjust Configuring Own Ship Mark OWN Ship Mark menu, setting windowOWN Ship Mark menu Ship shape description Interface Setting menu Interface Setting menuOther System Menu Items EXT Data Setting menu EXT Data Setting menuData sentences Nmea 0183, Furuno proprietary Others menu ES Draft OffsetCone Board Setting in the Processor Unit Adjustment of signal level echo sounder connectedAdjusting the volume of the audio alarm Processor unit, inside view DIP Switch Setting1 CIF2/NMEA2 connector interface selection Ifes Board 10P6983Choosing echosounder signal This page intentionally left blank Name Type Code No Qty Remarks Processor unit, front viewWiring between processor unit and CS-120A GNDDcon Board 10P6984 or 10P6984A This page intentionally left blank Packing List FSV-301 58 58 58 58 58 付属品表 52#42#465.+5614 52 Page Page Page Hatai Hatai Hatai Hatai Hatai Page Page This page is intentionally left blank Color Scanning Sonar Miyosi