Furuno FSV-30S installation manual Input Voltage and Fuses, Input voltage, Marking the label

Page 40

2.6 Input Voltage and Fuses

The transceiver unit is shipped from the factory with its input voltage set for 230 VAC and a 10 A fuse inserted in F601 and F602. For other voltages, change toggle switch positions and fuses as below.

Input voltage

Set the toggle switches S603, S604 and S605 according to input voltage, referring to the table below.

Input

S603

S604

S605

Default setting

(TB-B101)

 

 

 

 

100 V

L

L

L

 

110 V

H

L

L

 

115 V

H

H

L

 

220 V

H

L

H

 

230 V

H

H

H

Default setting

Fuses

Change the fuse in F601 and F602 according to input voltage, referring to the table below.

Input

 

Fuse

Default

(TB-B101)

F601

F602

setting

100 V

 

 

 

110 V

20A

20A

 

115 V

 

 

 

220 V

10A

10A

Default

230 V

setting

 

 

WARNING

Use the proper fuse.

Use of a wrong fuse can result in damage to the equipment or cause fire.

Marking the label

After setting toggle switches and changing the fuses, mark the voltage which applies on the label on the inside of the cover. In the example shown right, 100 V is marked so 20A fuses must be used.

FUSE

FUSE

F601

F602

INPUT

FUSE

(TB-B101)

F601

F602

100V

 

 

110V

20A

20A

115V

 

 

220V

10A

10A

230V

 

 

2-18

Image 40
Contents Color Scanning Sonar 00014857415 Safety Instructions Projected Raising Lowering Mm stroke Max kt System Configuration IiiStandard supply Optional EquipmentMounting considerations Hull UnitHull unit mounting location Maintenance space, example sonar compartment Shortening the retraction tank Guidelines for shortening the retraction tankRemarks for installation of retraction tank How to install reinforcement ribsInstalling hull unit on retraction tank Installation of hull unit Proper installation of stays Installing stays anti-vibration measureProper and improper stay installation methods Mounting considerations Processor UnitProcessor unit, rear view Mounting procedure Control UnitProcessor unit Rubber feetHow to attach KB fixing plate Mounting without KB fixing plateControl unit Mounting with KB fixing plateControl unit, cover removed Control unit, side viewTransceiver Unit Grounding the EquipmentTransceiver unit Transceiver unit, junction box Use copper strap suppliedProcedure Installing the Attachment Flange optionAttachment flange Type OP10-27, Code no Cable Extension Kit option Junction boxInstalling the Attachment Kit option Attachment kit Type OP10-24, Code noInstallation of attachment kit How to Use the Crimping Tool, Pin Extractor How to use the crimping toolHow to use the pin extractor Crimping tool, contact pin, pin extractorWiring WiringTransceiver unit side 1 10S1258-1 cable Cable type 10S1258-1, sectional viewFabrication of connector 00-8016-038-313761HV CN-A101 Fabrication of cable for connector 00-8016-038-313761HVAssembling 38P connector Positioning guide pinsAssembling connector NCS-253-P Power cableControl cable Cable list Sectional view of cablesGyro Menu setting Synchronizing with echo sounder or other sonarFor current driven KP input For voltage driven KP 12 V inputFabrication of connector 00-8016-038-313761HV CN-B101 Fabrication of cable for 00-8016-038-313761HVTransceiver unit, inside view CN-B101 CN-B102Hull control cable 10S2078 Fabrication of power cable type DPYCYS-2.5 TB-B101Fabrication of cable type DPYCYS-2.5 Wiring in transceiver unit Transceiver unit, top viewJunction box Cable Extension KitJunction box, cover removed Signal cable 10S2240 connects to Junction BOX display side Raise/Lower control box Raise/lower control box, cover removedPower cable fabrication Input Voltage and Fuses Input voltageFuses Marking the labelMain menu Hull Unit CheckOthers menu Initial Setting menu Test menuTransducer switches of the control unit How to check the hull unitControl unit in hull unit Page Heading adjustment Heading AdjustmentSystem menu Others menu, Heading Adjust OWN Ship Mark menu, setting window Configuring Own Ship MarkOWN Ship Mark menu Ship shape description Interface Setting menu Interface Setting menuOther System Menu Items EXT Data Setting menu EXT Data Setting menuData sentences Nmea 0183, Furuno proprietary Others menu ES Draft OffsetAdjustment of signal level echo sounder connected Cone Board Setting in the Processor UnitAdjusting the volume of the audio alarm DIP Switch Setting 1 CIF2/NMEA2 connector interface selectionProcessor unit, inside view Ifes Board 10P6983Choosing echosounder signal This page intentionally left blank Name Type Code No Qty Remarks Processor unit, front viewWiring between processor unit and CS-120A GNDDcon Board 10P6984 or 10P6984A This page intentionally left blank Packing List FSV-301 58 58 58 58 58 付属品表 52#42#465.+5614 52 Page Page Page Hatai Hatai Hatai Hatai Hatai Page Page This page is intentionally left blank Color Scanning Sonar Miyosi