3.4.3 OTHERS menu

 

MENU

 

QUIT

 

 

 

 

 

 

 

OTHERS

 

QUIT

 

 

 

 

 

 

 

LANGUAGE

: English

 

 

 

 

 

 

 

HEADING ADJUST

: 0

 

 

 

ES2 SELECT

: ES

 

 

ES DRAFT OFFSET : 0.0 m

 

 

EVENT KEY

: EVENT

 

 

AUTO TILT

: WIDE

 

 

SELECT USER PROG

: H/V INTERLOCK

 

TRACKBALL SPEED : NORMAL

HULL UNIT STROKE : 1200mm

OTHERS menu

LANGUAGE

Choose the language to use. (JAPANESE, ENGLISH)

HEADING ADJUST

See “3.2 Heading Adjustment”.

ES2 SELECT

Choose the equipment connected to the ES2 port; echo sounder or net recorder. (ES, NET REC)

ES DRAFT OFFSET

When connecting an echosounder, you may enter the ship’s draft if you prefer to display depth from the draft rather than depth from the transducer. (0.0 m to 10.0 m, increments of 0.1 m)

EVENT KEY

Choose the key to use to enter own ship’s position, EVENT or SHOOT. When choosing SHOOT, the shoot function becomes inoperative. (EVENT, SHOOT)

AUTO TILT

Choose the range for the auto tilt form WIDE (±2 to 10°, ±4 to 16°, ±6 to 20°) or NARROW (±1 to 4°, ±2 to 6°, ±3 to 8°). (WIDE, NARROW)

SELECT USER PROG

Choose whether to program horizontal and vertical displays together or individually, by the USER PROG control. H/V INTERLOCK, the default setting, commonly applies control settings to the horizontal and vertical displays. H/V INDVIDUAL enables individual adjustment of horizontal and vertical displays.

3-12

Image 52
Contents Color Scanning Sonar 00014857415 Safety Instructions Projected Raising Lowering Mm stroke Max kt System Configuration IiiStandard supply Optional EquipmentMounting considerations Hull UnitHull unit mounting location Maintenance space, example sonar compartment Shortening the retraction tank Guidelines for shortening the retraction tankRemarks for installation of retraction tank How to install reinforcement ribsInstalling hull unit on retraction tank Installation of hull unit Proper installation of stays Installing stays anti-vibration measureProper and improper stay installation methods Mounting considerations Processor UnitProcessor unit, rear view Mounting procedure Control UnitProcessor unit Rubber feetHow to attach KB fixing plate Mounting without KB fixing plateControl unit Mounting with KB fixing plateControl unit, cover removed Control unit, side viewTransceiver Unit Grounding the EquipmentTransceiver unit Transceiver unit, junction box Use copper strap suppliedProcedure Installing the Attachment Flange optionAttachment flange Type OP10-27, Code no Cable Extension Kit option Junction boxInstalling the Attachment Kit option Attachment kit Type OP10-24, Code noInstallation of attachment kit How to Use the Crimping Tool, Pin Extractor How to use the crimping toolHow to use the pin extractor Crimping tool, contact pin, pin extractorWiring WiringTransceiver unit side 1 10S1258-1 cable Cable type 10S1258-1, sectional viewFabrication of connector 00-8016-038-313761HV CN-A101 Fabrication of cable for connector 00-8016-038-313761HVAssembling 38P connector Positioning guide pinsAssembling connector NCS-253-P Power cableControl cable Cable list Sectional view of cablesGyro Menu setting Synchronizing with echo sounder or other sonarFor current driven KP input For voltage driven KP 12 V inputFabrication of connector 00-8016-038-313761HV CN-B101 Fabrication of cable for 00-8016-038-313761HVTransceiver unit, inside view CN-B101 CN-B102Hull control cable 10S2078 Fabrication of power cable type DPYCYS-2.5 TB-B101Fabrication of cable type DPYCYS-2.5 Wiring in transceiver unit Transceiver unit, top viewJunction box Cable Extension KitJunction box, cover removed Signal cable 10S2240 connects to Junction BOX display side Raise/Lower control box Raise/lower control box, cover removedPower cable fabrication Input Voltage and Fuses Input voltageFuses Marking the labelMain menu Hull Unit CheckOthers menu Initial Setting menu Test menuTransducer switches of the control unit How to check the hull unitControl unit in hull unit Page Heading adjustment Heading AdjustmentSystem menu Others menu, Heading Adjust OWN Ship Mark menu, setting window Configuring Own Ship MarkOWN Ship Mark menu Ship shape description Interface Setting menu Interface Setting menuOther System Menu Items EXT Data Setting menu EXT Data Setting menuData sentences Nmea 0183, Furuno proprietary Others menu ES Draft OffsetAdjustment of signal level echo sounder connected Cone Board Setting in the Processor UnitAdjusting the volume of the audio alarm DIP Switch Setting 1 CIF2/NMEA2 connector interface selectionProcessor unit, inside view Ifes Board 10P6983Choosing echosounder signal This page intentionally left blank Name Type Code No Qty Remarks Processor unit, front viewWiring between processor unit and CS-120A GNDDcon Board 10P6984 or 10P6984A This page intentionally left blank Packing List FSV-301 58 58 58 58 58 付属品表 52#42#465.+5614 52 Page Page Page Hatai Hatai Hatai Hatai Hatai Page Page This page is intentionally left blank Color Scanning Sonar Miyosi