2.5.2 Raise/Lower control box
Connect the power cable (3φ) and the transceiver unit cable (10S2078) as shown below.
Connect the transceiver cable (10S2078) here.
| Cable | |
| Sheath | |
Armor | ||
Connect the power cable | ||
| ||
(Japan Industrial Standard) or the |
| |
equivalent cable to this terminal board. | Vinyl | |
| ||
LED (Red) | sheath | |
For detection of phase reversal on | Conductor | |
3 phase power cable | S = 4 mm2 | |
| ∅ = 2.55 mm |
Confirm LED after completing the installation. The LED lights (in red) if power connection is correct. If it is off, turn off power from the mains switchboard, check the cable connection and recheck the LED. The hull unit does not work if this connection is wrong.
Normal phase: LED lights (in red).
Phase reversal: LED does not light.
Power cable (3φ) |
Cable from transceiver unit 10S2078