Furuno FSV-30S installation manual EXT Data Setting menu

Page 50

3.4.2 EXT DATA SETTING menu

MENU

 

QUIT

 

 

 

EXT DATA SETTING

 

QUIT

 

 

 

DATE&TIME

: CIF

HEADING

: AD10S

LOG PULSE

: 200p/NM

SPEED&COURSE

: NMEA

SPEED SENSOR

: GPS/DR

LAT/LON

: NMEA

POSITIONING SENSOR

: AUTO SEL.

WATER DEPTH

: NMEA

WATER TEMP.

: NMEA

WATER CURRENT

: CIF

WIND

: CIF

NET DEPTH

: PULSE

 

 

 

EXT DATA SETTING menu

DATE & TIME

Choose the input format for data and time data. (NONE, CIF, NMEA)

HEADING

Choose the input format for heading data. (NONE, AD10S, CIF, NMEA)

LOG PULSE

Set the log pulse rate for the log signal. (200 p/NM, 400 p/NM)

SPEED & COURSE

Choose the input format for ship’s speed and course data. When choosing the LOG&HEADING, the heading data is used instead of the course data. (NONE, LOG&HEADING, CIF, NMEA)

SPEED SENSOR

Choose the input format for speed and course data. This setting is ineffective when LOG&HEADING is selected as speed and course source.

(NONE, GPS/DR, DOPPLER/DR)

LAT/LON

Choose the input format for ship’s position data. (NONE, CIF, NMEA)

POSITIONING SENSOR

Choose the type of the navigator to use. For AUTO SEL., the priority is GPS/DR>LORAN-C. (LORAN-C, GPS/DR, AUTO SEL.)

3-10

Image 50
Contents Color Scanning Sonar 00014857415 Safety Instructions Projected Raising Lowering Mm stroke Max kt System Configuration IiiStandard supply Optional EquipmentHull unit mounting location Hull UnitMounting considerations Maintenance space, example sonar compartment Shortening the retraction tank Guidelines for shortening the retraction tankRemarks for installation of retraction tank How to install reinforcement ribsInstalling hull unit on retraction tank Installation of hull unit Proper and improper stay installation methods Installing stays anti-vibration measureProper installation of stays Processor unit, rear view Processor UnitMounting considerations Processor unit Mounting procedureControl Unit Rubber feetControl unit How to attach KB fixing plateMounting without KB fixing plate Mounting with KB fixing plateControl unit, cover removed Control unit, side viewTransceiver unit Transceiver UnitGrounding the Equipment Transceiver unit, junction box Use copper strap suppliedAttachment flange Type OP10-27, Code no Installing the Attachment Flange optionProcedure Cable Extension Kit option Junction boxInstalling the Attachment Kit option Attachment kit Type OP10-24, Code noInstallation of attachment kit How to use the pin extractor How to Use the Crimping Tool, Pin ExtractorHow to use the crimping tool Crimping tool, contact pin, pin extractorWiring WiringTransceiver unit side 1 10S1258-1 cable Cable type 10S1258-1, sectional viewAssembling 38P connector Fabrication of connector 00-8016-038-313761HV CN-A101Fabrication of cable for connector 00-8016-038-313761HV Positioning guide pinsControl cable Power cableAssembling connector NCS-253-P Cable list Sectional view of cablesGyro For current driven KP input Menu settingSynchronizing with echo sounder or other sonar For voltage driven KP 12 V inputFabrication of connector 00-8016-038-313761HV CN-B101 Fabrication of cable for 00-8016-038-313761HVTransceiver unit, inside view CN-B101 CN-B102Fabrication of cable type DPYCYS-2.5 Fabrication of power cable type DPYCYS-2.5 TB-B101Hull control cable 10S2078 Wiring in transceiver unit Transceiver unit, top viewJunction box, cover removed Cable Extension KitJunction box Signal cable 10S2240 connects to Junction BOX display side Raise/Lower control box Raise/lower control box, cover removedPower cable fabrication Fuses Input Voltage and FusesInput voltage Marking the labelOthers menu Hull Unit CheckMain menu Initial Setting menu Test menuControl unit in hull unit How to check the hull unitTransducer switches of the control unit Page System menu Heading AdjustmentHeading adjustment Others menu, Heading Adjust OWN Ship Mark menu Configuring Own Ship MarkOWN Ship Mark menu, setting window Ship shape description Other System Menu Items Interface Setting menuInterface Setting menu EXT Data Setting menu EXT Data Setting menuData sentences Nmea 0183, Furuno proprietary Others menu ES Draft OffsetAdjusting the volume of the audio alarm Cone Board Setting in the Processor UnitAdjustment of signal level echo sounder connected Processor unit, inside view DIP Switch Setting1 CIF2/NMEA2 connector interface selection Ifes Board 10P6983Choosing echosounder signal This page intentionally left blank Name Type Code No Qty Remarks Processor unit, front viewWiring between processor unit and CS-120A GNDDcon Board 10P6984 or 10P6984A This page intentionally left blank Packing List FSV-301 58 58 58 58 58 付属品表 52#42#465.+5614 52 Page Page Page Hatai Hatai Hatai Hatai Hatai Page Page This page is intentionally left blank Color Scanning Sonar Miyosi