Furuno FSV-30S installation manual Wiring between processor unit and CS-120A, Gnd

Page 58

2.Remove two upset screws, detach the plugs J503, J502, J501, J504, J506 and J507, and then pull out the power module.

 

Protection sheet

VH4P

Spacer

 

Power supply

 

Detach J503, J502,

VH5P

J501, J504 and

pcb

J506.

Upset screws

Power Module

 

M5x25 SUS 2 pcs.

 

Pin

Hole

Detach J507.

Processor unit, front view

3.Fix the power supply pcb (supplied) to the power module with spacers (supplied).

4.Connect two VH connectors (provided on the power module) to the power supply pcb.

5.Set the protection sheet (supplied) to the power supply pcb and fasten it with four screws.

6.Reattach the power module.

7.Connect between the processor unit and CS-120A as follows.

Processor Unit

+24V_H 1

+24V_C 2

GND 3

POWER FOR CS-120A port NJC-203-PM

YEL BRN

ORG BRN

PPL BRN

CIF1 or NMEA2/CIF2 port

CS-120A J201

L24V

E 0V

PP GND

CIF_TXD_H 1

CIF_TXD_C 2

CIF_RXD_H 3

CIF_RXD_C 4

SHIELD 10

37-core cable

10S1258

NNTD-H MM TD-C

JJ RD-H KK RD-C BB GND EE DSR-C DD DSR-H

Z DTR-H

Wiring between processor unit and CS-120A

Note: An echosounder should be connected to the processor unit directly.

4-2

Image 58
Contents Color Scanning Sonar 00014857415 Safety Instructions Projected Raising Lowering Mm stroke Max kt System Configuration IiiStandard supply Optional EquipmentMounting considerations Hull UnitHull unit mounting location Maintenance space, example sonar compartment Shortening the retraction tank Guidelines for shortening the retraction tankRemarks for installation of retraction tank How to install reinforcement ribsInstalling hull unit on retraction tank Installation of hull unit Proper installation of stays Installing stays anti-vibration measureProper and improper stay installation methods Mounting considerations Processor UnitProcessor unit, rear view Processor unit Mounting procedureControl Unit Rubber feetControl unit How to attach KB fixing plateMounting without KB fixing plate Mounting with KB fixing plateControl unit, cover removed Control unit, side viewTransceiver unit Transceiver UnitGrounding the Equipment Transceiver unit, junction box Use copper strap suppliedProcedure Installing the Attachment Flange optionAttachment flange Type OP10-27, Code no Cable Extension Kit option Junction boxInstalling the Attachment Kit option Attachment kit Type OP10-24, Code noInstallation of attachment kit How to use the pin extractor How to Use the Crimping Tool, Pin ExtractorHow to use the crimping tool Crimping tool, contact pin, pin extractorWiring WiringTransceiver unit side 1 10S1258-1 cable Cable type 10S1258-1, sectional viewAssembling 38P connector Fabrication of connector 00-8016-038-313761HV CN-A101Fabrication of cable for connector 00-8016-038-313761HV Positioning guide pinsAssembling connector NCS-253-P Power cableControl cable Cable list Sectional view of cablesGyro For current driven KP input Menu settingSynchronizing with echo sounder or other sonar For voltage driven KP 12 V inputFabrication of connector 00-8016-038-313761HV CN-B101 Fabrication of cable for 00-8016-038-313761HVTransceiver unit, inside view CN-B101 CN-B102Hull control cable 10S2078 Fabrication of power cable type DPYCYS-2.5 TB-B101Fabrication of cable type DPYCYS-2.5 Wiring in transceiver unit Transceiver unit, top viewJunction box Cable Extension KitJunction box, cover removed Signal cable 10S2240 connects to Junction BOX display side Raise/Lower control box Raise/lower control box, cover removedPower cable fabrication Fuses Input Voltage and FusesInput voltage Marking the labelMain menu Hull Unit CheckOthers menu Initial Setting menu Test menuTransducer switches of the control unit How to check the hull unitControl unit in hull unit Page Heading adjustment Heading AdjustmentSystem menu Others menu, Heading Adjust OWN Ship Mark menu, setting window Configuring Own Ship MarkOWN Ship Mark menu Ship shape description Interface Setting menu Interface Setting menuOther System Menu Items EXT Data Setting menu EXT Data Setting menuData sentences Nmea 0183, Furuno proprietary Others menu ES Draft OffsetAdjustment of signal level echo sounder connected Cone Board Setting in the Processor UnitAdjusting the volume of the audio alarm Processor unit, inside view DIP Switch Setting1 CIF2/NMEA2 connector interface selection Ifes Board 10P6983Choosing echosounder signal This page intentionally left blank Name Type Code No Qty Remarks Processor unit, front viewWiring between processor unit and CS-120A GNDDcon Board 10P6984 or 10P6984A This page intentionally left blank Packing List FSV-301 58 58 58 58 58 付属品表 52#42#465.+5614 52 Page Page Page Hatai Hatai Hatai Hatai Hatai Page Page This page is intentionally left blank Color Scanning Sonar Miyosi