2.Remove two upset screws, detach the plugs J503, J502, J501, J504, J506 and J507, and then pull out the power module.
| Protection sheet | |
VH4P | Spacer | |
| ||
Power supply |
| Detach J503, J502, |
VH5P | J501, J504 and | |
pcb | J506. | |
Upset screws | Power Module | |
| ||
M5x25 SUS 2 pcs. |
|
Pin
Hole
Detach J507.
Processor unit, front view
3.Fix the power supply pcb (supplied) to the power module with spacers (supplied).
4.Connect two VH connectors (provided on the power module) to the power supply pcb.
5.Set the protection sheet (supplied) to the power supply pcb and fasten it with four screws.
6.Reattach the power module.
7.Connect between the processor unit and
Processor Unit
+24V_H 1
+24V_C 2
GND 3
POWER FOR
YEL BRN
ORG BRN
PPL BRN
CIF1 or NMEA2/CIF2 port
L24V
E 0V
PP GND
CIF_TXD_H 1
CIF_TXD_C 2
CIF_RXD_H 3
CIF_RXD_C 4
SHIELD 10
10S1258
NN
JJ
Z
Wiring between processor unit and CS-120A
Note: An echosounder should be connected to the processor unit directly.