1. MOUNTING

1.4Hull Unit

1.4.1General mounting considerations

Noise and air bubbles will affect performance.

Do not turn on the equipment with the transducer exposed to air. Exposing the transducer to air may damage it.

1.4.2Installation position considerations

Discussion and agreement are required with the dockyard and ship owner in deciding the location for the hull unit. When deciding the location, take into account the following points:

Select an area where propeller noise, cruising noise, bubbles and interference from turbulence are minimal. Generally, the point at 1/3 to 1/2 of the ship’s length from the bow or near the keel is the best. On-the-keel installation is advantageous for minimizing oil consumption in comparison with off-the-keel. If the hull unit cannot be installed on the keel, the center of the retraction tank should be within 1 meter of the keel to prevent a rolling effect.

1/2

1/3

Within 1 meter

 

 

Installation location for hull unit

Select a place where interference from the transducers of other sounding equipment is minimal. The hull unit should be at least 2.5 meters away from the transducers of other sounding equipment.

An obstacle in the fore direction not only causes a shadow zone but also aerated water, resulting in poor sonar performance. Be sure to locate the transducer well away from any obstacle in the fore direction.

Mounting method

A typical mounting method is shown in the outline drawing at the back of this manual. Consult ship’s owner, dockyard and user to determine appropriate mounting method. Pay attention to safety (strength, watertightness) first, followed by ease of maintenance and inspection.

1-8

Image 16
Contents DUAL-FREQUENCY Searchlight Sonar 00015190211 Safety Instructions Working with the Sonaroil Table of Contents System Configuration Equipment Lists Standard SupplyOptions Monitor Unit/Control Unit Mounting baseBracket, rear view Fastening bracket to mounting baseMounting separated monitor unit Bracket rear view Control Unit Blackbox typeHex. bolts Fixing metal Transceiver Unit Transceiver unitInstallation location for hull unit Hull UnitTransducer tank Assembling and mounting of hull unit Shaft sleeve and raise/lower drive unit assembly Trunnion pinApplying Cemedine High Super to main shaft Tank and tank guide, sectional viewInstalling shims 1800 1600 1400 1200 Tank guide attachment Installing grease cotton on the main shaft Detaching the soundome Filling the soundome with sonar oilEmergency Paint area Mounting Checking manual raise/lower of soundome with hand crank Interface Unit Motion Sensor MS-100 option Mounting considerationsClinometer BS-704 option Wiring Wiring Among UnitsWiring, with monitor WiringWiring, without monitor MJ-A6SPF DPYCYS-2.5TB1 Transceiver unit, internal viewConnection of transceiver unit to other sonar/echo sounder Outputting KP of CH-300 to other sonar, echo sounderHull unit, inside view VGA NAV I/O Sentences Available I/O sentencesGeneral Checks General checksGeneral checks con’t Checking TX FrequencyUser menu SYS System menu Test displayChecking heading alignment Heading Alignment SettingHeading offset display Menu COM1 Setting for Synchronizing Transmission with other EquipmentTX Rate window Setting for Satellite Compass System setting 1 menuSystem setting 2 menu Setting of Motion Sensor/Satellite Compass Adj motion sensor menuSystem backup menu System Back UpSetting of Interface Unit Interface unit, DIP switch S1 location+/05+105+0&4#9+014440%10. +/05+105+0&4#9+014440%10.#8 #%%5514+5 㩖㩡㩧㩆㩨 #8 Page Page Page Page Page Page Page Hatai This page is intentionally left blank Page Page Page Page Page Page Page Hatai Page This page is intentionally left blank Page Page Page Page Page 2周波サーチライトソナー 2周波サーチライトソナーI/Fユニット使用