SYSTEM CONFIGURATION

INTERFACE UNIT IF-8000

MONITOR UNIT MU-100C

Note 2

Navigator

Control Unit

Display

Unit

VGA Ext.

Remote

Monitor

Controller

CONTROL UNIT CH-302

Note 1

Note 2

TRANSCEIVER UNIT

CH-303

12-24 VDC

DATA/VIDEOOUT

Speaker

Motion Sensor

Satellite compass

or

NMEA Input

Rectifier

RU-1746B-2

100/110/200/220 VAC

12-24 VDC

12/24 VDC

Note 1: MU-100C is the standard supply monitor unit. An external monitor may be connected via the interface unit (option). The drawing above shows the system configuration with the MU-100C.

Note 2: For blackbox type, MU-100C is not supplied. Connect external monitor (user supply) and control unit to the interface unit.

HULL UNIT CH-304/305

iv

Image 6
Contents DUAL-FREQUENCY Searchlight Sonar 00015190211 Safety Instructions Working with the Sonaroil Table of Contents System Configuration Equipment Lists Standard SupplyOptions Monitor Unit/Control Unit Mounting baseBracket, rear view Fastening bracket to mounting baseMounting separated monitor unit Bracket rear view Control Unit Blackbox typeHex. bolts Fixing metal Transceiver Unit Transceiver unitInstallation location for hull unit Hull UnitTransducer tank Assembling and mounting of hull unit Shaft sleeve and raise/lower drive unit assembly Trunnion pinApplying Cemedine High Super to main shaft Tank and tank guide, sectional viewInstalling shims 1800 1600 1400 1200 Tank guide attachment Installing grease cotton on the main shaft Detaching the soundome Filling the soundome with sonar oilEmergency Paint area Mounting Checking manual raise/lower of soundome with hand crank Interface Unit Motion Sensor MS-100 option Mounting considerationsClinometer BS-704 option Wiring Wiring Among UnitsWiring, with monitor WiringWiring, without monitor MJ-A6SPF DPYCYS-2.5TB1 Transceiver unit, internal viewConnection of transceiver unit to other sonar/echo sounder Outputting KP of CH-300 to other sonar, echo sounderHull unit, inside view VGA NAV I/O Sentences Available I/O sentencesGeneral Checks General checksChecking TX Frequency General checks con’tUser menu SYS System menu Test displayHeading Alignment Setting Checking heading alignmentHeading offset display Setting for Synchronizing Transmission with other Equipment Menu COM1TX Rate window Setting for Satellite Compass System setting 1 menuSystem setting 2 menu Setting of Motion Sensor/Satellite Compass Adj motion sensor menuSystem backup menu System Back UpSetting of Interface Unit Interface unit, DIP switch S1 location+/05+105+0&4#9+014440%10. +/05+105+0&4#9+014440%10.#8 #%%5514+5 㩖㩡㩧㩆㩨 #8 Page Page Page Page Page Page Page Hatai This page is intentionally left blank Page Page Page Page Page Page Page Hatai Page This page is intentionally left blank Page Page Page Page Page 2周波サーチライトソナー 2周波サーチライトソナーI/Fユニット使用