Furuno CH300 manual Monitor Unit/Control Unit, Mounting base

Page 9

1.MOUNTING

NOTICE

Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment.

Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors.

1.1Monitor Unit/Control Unit

This searchlight sonar has two types of shipments, unibody type which is shipped with monitor unit, and blackbox type which is shipped without a monitor unit, but has an interface unit. For blackbox type, see page 1-5.

The control unit can be installed together with the monitor unit, or independently of the monitor unit. For separate installation, the optional monitor kit is required. These units can be installed on a tabletop or flush mounted in a console or panel.

1.1.1General mounting considerations

Keep the monitor unit out of direct sunlight.

Select a location where the unit(s) can easily be operated while observing the fishing ground or area surrounding the vessel.

For maintenance and checking purposes, leave sufficient space at the sides and rear of the unit and leave slack in cable. (Refer to the outline drawing at the back of this manual.)

1.1.2Mounting Unibody type

1.Fasten the mounting base to the mounting location with four self-tapping screws (5X20).

FRONT

Mounting base

2.Fasten the bracket at the rear of monitor/control unit with four binding screws (M4x10).

1-1

Image 9
Contents DUAL-FREQUENCY Searchlight Sonar 00015190211 Safety Instructions Working with the Sonaroil Table of Contents System Configuration Standard Supply Equipment ListsOptions Mounting base Monitor Unit/Control UnitFastening bracket to mounting base Bracket, rear viewMounting separated monitor unit Bracket rear view Blackbox type Control UnitHex. bolts Fixing metal Transceiver unit Transceiver UnitHull Unit Installation location for hull unitTransducer tank Assembling and mounting of hull unit Trunnion pin Shaft sleeve and raise/lower drive unit assemblyTank and tank guide, sectional view Applying Cemedine High Super to main shaftInstalling shims 1800 1600 1400 1200 Tank guide attachment Installing grease cotton on the main shaft Filling the soundome with sonar oil Detaching the soundomeEmergency Paint area Mounting Checking manual raise/lower of soundome with hand crank Interface Unit Mounting considerations Motion Sensor MS-100 optionClinometer BS-704 option Wiring Among Units WiringWiring Wiring, with monitorMJ-A6SPF DPYCYS-2.5 Wiring, without monitorTransceiver unit, internal view TB1Outputting KP of CH-300 to other sonar, echo sounder Connection of transceiver unit to other sonar/echo sounderHull unit, inside view VGA NAV Available I/O sentences I/O SentencesGeneral checks General ChecksChecking TX Frequency General checks con’tUser menu SYS Test display System menuHeading Alignment Setting Checking heading alignmentHeading offset display Setting for Synchronizing Transmission with other Equipment Menu COM1TX Rate window System setting 1 menu Setting for Satellite CompassSystem setting 2 menu Adj motion sensor menu Setting of Motion Sensor/Satellite CompassSystem Back Up System backup menuInterface unit, DIP switch S1 location Setting of Interface Unit+/05+105+0&4#9+014440%10. +/05+105+0&4#9+014440%10.#8 #%%5514+5 㩖㩡㩧㩆㩨 #8 Page Page Page Page Page Page Page Hatai This page is intentionally left blank Page Page Page Page Page Page Page Hatai Page This page is intentionally left blank Page Page Page Page Page 2周波サーチライトソナー 2周波サーチライトソナーI/Fユニット使用