Furuno CH300 manual System Back Up, System backup menu

Page 49

3. ADJUSTMENT

3.7System Back Up

After setting up the equipment, follow the procedure below to back up system settings. Backup data can be loaded in the event of equipment trouble, to restore previous system settings.

1.Press the MENU key to display the user menu.

2.Press ► to select SYS at the top of the menu.

3.Press ▼ to select GO TO SYS MENU.

4.Press ◄ to select YES. The system menu appears.

5.Press ▼ to select SYSTEM BACKUP.

6.Press ► to display the system backup menu.

**SYSTEM BACK UP**

ARE YOU SURE? :

NO

YES

NOTE: OVERWITES PREVIOUS BACKUP DATA

: CHANGE MENU: END

System backup menu

7.Press ► to select YES.

8.Press the MENU key to backup data.

The backup data is saved, and then return to the System menu.

9.Press the MENU key to return to the normal display.

3-9

Image 49
Contents DUAL-FREQUENCY Searchlight Sonar 00015190211 Safety Instructions Working with the Sonaroil Table of Contents System Configuration Standard Supply Equipment ListsOptions Mounting base Monitor Unit/Control UnitFastening bracket to mounting base Bracket, rear viewMounting separated monitor unit Bracket rear view Blackbox type Control UnitHex. bolts Fixing metal Transceiver unit Transceiver UnitHull Unit Installation location for hull unitTransducer tank Assembling and mounting of hull unit Trunnion pin Shaft sleeve and raise/lower drive unit assemblyTank and tank guide, sectional view Applying Cemedine High Super to main shaftInstalling shims 1800 1600 1400 1200 Tank guide attachment Installing grease cotton on the main shaft Filling the soundome with sonar oil Detaching the soundomeEmergency Paint area Mounting Checking manual raise/lower of soundome with hand crank Interface Unit Mounting considerations Motion Sensor MS-100 optionClinometer BS-704 option Wiring Among Units WiringWiring Wiring, with monitorMJ-A6SPF DPYCYS-2.5 Wiring, without monitorTransceiver unit, internal view TB1Outputting KP of CH-300 to other sonar, echo sounder Connection of transceiver unit to other sonar/echo sounderHull unit, inside view VGA NAV Available I/O sentences I/O SentencesGeneral checks General ChecksGeneral checks con’t Checking TX FrequencyUser menu SYS Test display System menuChecking heading alignment Heading Alignment SettingHeading offset display Menu COM1 Setting for Synchronizing Transmission with other EquipmentTX Rate window System setting 1 menu Setting for Satellite CompassSystem setting 2 menu Adj motion sensor menu Setting of Motion Sensor/Satellite CompassSystem Back Up System backup menuInterface unit, DIP switch S1 location Setting of Interface Unit+/05+105+0&4#9+014440%10. +/05+105+0&4#9+014440%10.#8 #%%5514+5 㩖㩡㩧㩆㩨 #8 Page Page Page Page Page Page Page Hatai This page is intentionally left blank Page Page Page Page Page Page Page Hatai Page This page is intentionally left blank Page Page Page Page Page 2周波サーチライトソナー 2周波サーチライトソナーI/Fユニット使用