Furuno CH300 manual Assembling and mounting of hull unit

Page 18

1. MOUNTING

Mounting of transducer tank

Install the transducer tank referring to the hull unit outline drawings at the back of this manual.

Note 1: When making a retraction tank locally, the inside diameter of the retraction tank should be φ 190±0.5 as shown in the outline at the back of this manual. If larger, the hull unit may be damaged.

Note 2: Locate the retraction tank so that the center of any two bolt holes is facing the ship’s bow.

a=b

a b

Bow

1.4.4Assembling and mounting of hull unit

The hull unit is shipped as the parts shown in the hull unit kit in the Equipment Lists (page v). Assemble the hull unit as shown in the procedure below.

Note: Confirm the frequency of soundome before mounting by referring to the table below.

Frequency

Specification

 

 

60/153 kHz

There is NO label attached on the dome.

85/215 kHz

There is the label “85/215 kHz” attached

 

 

on the dome.

 

 

 

 

For 85/215 kHz, the label is

 

attached here.

 

Necessary tools

Name

Specification

Remarks

 

 

 

Wrench

For M10 (Hex. size 17 mm)

Recommended: double offset wrench

 

 

 

Wrench

For M20 (Hex. size 30 mm)

 

 

 

 

Pipe Wrench

55 mm

For fixing gland

 

 

 

Ball Wrench

Hex size 4 mm

For fixing the dome

 

 

 

1-10

Image 18
Contents DUAL-FREQUENCY Searchlight Sonar 00015190211 Safety Instructions Working with the Sonaroil Table of Contents System Configuration Equipment Lists Standard SupplyOptions Monitor Unit/Control Unit Mounting baseBracket, rear view Fastening bracket to mounting baseMounting separated monitor unit Bracket rear view Control Unit Blackbox typeHex. bolts Fixing metal Transceiver Unit Transceiver unitInstallation location for hull unit Hull UnitTransducer tank Assembling and mounting of hull unit Shaft sleeve and raise/lower drive unit assembly Trunnion pinApplying Cemedine High Super to main shaft Tank and tank guide, sectional viewInstalling shims 1800 1600 1400 1200 Tank guide attachment Installing grease cotton on the main shaft Detaching the soundome Filling the soundome with sonar oilEmergency Paint area Mounting Checking manual raise/lower of soundome with hand crank Interface Unit Motion Sensor MS-100 option Mounting considerationsClinometer BS-704 option Wiring Wiring Among UnitsWiring, with monitor WiringWiring, without monitor MJ-A6SPF DPYCYS-2.5TB1 Transceiver unit, internal viewConnection of transceiver unit to other sonar/echo sounder Outputting KP of CH-300 to other sonar, echo sounderHull unit, inside view VGA NAV I/O Sentences Available I/O sentencesGeneral Checks General checksChecking TX Frequency General checks con’tUser menu SYS System menu Test displayHeading Alignment Setting Checking heading alignmentHeading offset display Setting for Synchronizing Transmission with other Equipment Menu COM1TX Rate window Setting for Satellite Compass System setting 1 menuSystem setting 2 menu Setting of Motion Sensor/Satellite Compass Adj motion sensor menuSystem backup menu System Back UpSetting of Interface Unit Interface unit, DIP switch S1 location+/05+105+0&4#9+014440%10. +/05+105+0&4#9+014440%10.#8 #%%5514+5 㩖㩡㩧㩆㩨 #8 Page Page Page Page Page Page Page Hatai This page is intentionally left blank Page Page Page Page Page Page Page Hatai Page This page is intentionally left blank Page Page Page Page Page 2周波サーチライトソナー 2周波サーチライトソナーI/Fユニット使用