MIDI CLOCK

The unit recognizes MIDI Clock messages and applies the tempo (40 to 400bpm) to programs that use Tap Tempo. Connect a MIDI device that outputs MIDI Clock, such as the MPX R1 foot controller or a MIDI sequencer, to the MPX 550 MIDI IN connector to have the MPX 550 automatically recognize and begin to process MIDI Clock messages. When the tempo of the connected device changes, the unit will automatically adjust its delay times and modulation rates to match the new tempo.

This feature can be disabled with the System Mode parameter MIDI Clock In.

Note:

When System Mode is active, the unit will not respond to MIDI Clock messages. Once System Mode is deactivated, the unit will resume responding to MIDI Clock messages.

MIDI DUMPS

MIDI Dumps can be used to save the user programs, the selected program, or the System Mode settings and Learned Patch assignments to a storage device (typically a MIDI sequencer). MIDI Dumps are performed in System Mode (see page 3-8).

To perform a dump of the user programs, the selected program, or the System Mode settings and Learned Patches:

1.Press the front panel System button. The System LED will light to indicate that System Mode is active.

2.Use the EDIT knob 1 to select:

Dump User Bank

Executes a dump of user programs. Use Edit knob 3 to select the desired range of user programs: (1-16), (17-32), (33-48), or (49 to 64). When a user program dump is returned to the unit from a MIDI storage device, the unit saves it in the appropriate User Bank locations.

6-6

Image 98
Contents Page Important Safety Instructions Communications Notice Introduction System Mode English Instrucciones DE Seguridad Italiano Importanti Norme DI Sicurezza Vii Viii US Important User Information DE Wichtige Benutzerinformation ES Información importante para el usuario FR Important Informations Utilisateur IT Importanti informazioni per l’utente PT Informações Importantes ao usuário Getting Started Getting Started About the MPXHighlights Edit Pages Front Panel OverviewInput Trim SystemEdit Knobs Tap/CancelPower StoreInput Level Meters Input/OVL IndicatorFront Panel Display Edit Knobs 1 to Routing ConfigurationBank Name TempoRear Panel Overview AC Input ConnectorProvides power to the unit with the supplied power CordAnalog INPUTs Pdif in and OUTAnalog OUTPUTs Connecting the Unit FootswitchTypical Connections to a Console Output Setting Audio LevelsInput Basic Operation Basic Operation Selecting and Loading ProgramsAdjust Parameter Editing ProgramsStoring Programs Compressor TAP Tempo Matching Rhythm Audio TAPGlobal Tempo BypassSystem Mode System Mode Functions Parameter SettingsParameter Settings Midi Dumps Settings if applicable Restore Default CommandsInput Source ParametersOutput Level Clock SourceProgram Load Mode Mix Mode Program, GlobalBypass Mode Dry, Full Mute, Input Mute Tempo Mode Program, GlobalOperating Mode Normal, Demo, Locked Midi Patches Enabled, DisabledMidi Clock Enabled, Disabled Midi Channel Off, 1 to 16, OmniDisplay Brightness Memory Protect Enabled, DisabledAuto Load Enabled, Disabled Dump Current Program Midi DumpsDump User Bank Dump System DataFactory Init Restore Default CommandsClear User Bank Program Descriptions Plate Programs Adjust Tap Single Programs PlateGate/Inv Programs Adjust Tap GATE/INVHall Programs Adjust Tap HallChamber Programs Adjust Tap ChamberAmbience Programs Adjust Tap AmbienceRoom Programs Adjust Tap RoomTremolo Programs Adjust Tap TremoloRotary Programs Adjust Tap RotaryChorus Programs Adjust Tap ChorusFlange Programs Adjust Tap FlangeDetune Programs Adjust Tap DetunePitch Programs Adjust Tap PitchDLY/EKO Dly/Eko Programs Adjust Tap Special FX Programs Adjust Tap Special FXStereo Stage Dual Mono Dual ProgramsMSplit Dly, MSplit Rvb Pitch Delay EFX BALFlng-Dly Programs Adjust Tap Routing FLNG-DLYPch-Dly Programs Adjust Tap Routing PCH-DLYChor-Dly Programs Adjust Tap Routing CHOR-DLYDly-Rvb Programs Adjust Tap Routing DLY-RVBTap Routing FLNG-RVBFlng-Rvb Programs Pch-Rvb Programs Adjust Tap Routing PCH-RVBChor-Rvb Programs Adjust Tap Routing CHOR-RVBMSplit Dly Programs Adjust Tap Routing Msplit DLYMSplit Rvb Programs Adjust Tap Routing Msplit RVBProgram Descriptions Dual Mono Programs Adjust Tap Routing Dual MonoComprssr Programs Adjust Tap CmprssrExpThrsh DynamicsPeak Expansion ExpLvl 0dB to 5.89dBCompression Saturation Off, Modern, Vintage Tape SaturationLevel Meters Gain Min, 1 to 30, MaxInput Meter Typical Mastering Dynamics Control AdjustmentPeak Expansion Meter Gain Reduction MeterTypical Mastering Dynamics Control Adjustment LIVE-FOH Front of HouseLive-FOH Programs Adjust Tap Parameter Descriptions Parameter Descriptions Parameter GraphicsParameter Descriptions Parameter Glossary Diffusion CmpRels To 250msecDepth Dly Fbk To 100%Drum Res DlyTapLvlDrum Dep To 100% Duration 140 to 700msHorn Res HighSlope and LowSlopeHorn Dep To 100% IntrvlMix Dry, 1 to 99%, Wet Phase To 270degPreDelay 0ms to 1.198sec MstrRate To 100%Shape Rate To 50.05Hz RvbLvlRes 1 ResonancSpread SpeedSpeed 1 Sweep To 100msWidth Setting DescriptionWavform Midi Operation Learn Mode Midi Channel AssignmentProgram Change Messages Loading Programs Midi Program BanksActivating Bypass or TAP Functions Continuous ControllersMidi Operation Midi Clock Sysex Messages Midi Implementation Chart Function Transmitted Recognized RemarksYes Appendix Specifications AppendixDeclaration of Conformity Index Index MPX Limited Warranty Customer Support Dry Tracks Total Time