MIDI Operation

2.Turn the desired EDIT knob or press the desired button on the front panel. The front panel display will indicate which control is selected, as well as the current controller range.

3.Select the desired controller using one of the following methods:

A.Move the MIDI controller through its full range. To use a portion of the controller range, limit this movement to the desired range. The message area on the front panel display will indicate incoming MIDI activity.

B.Rotate the EDIT knob until the desired Controller number is displayed. The full range of the Controller (0 to 127) will be assumed. This method is not available for Bypass and Tap.

4.Press the Store button to commit to the assignment. The word "Stored" will appear briefly in the message area of the front panel display.

5.To assign another front panel control, repeat steps 2 to 4.

6.Simultaneously press the Store and Tap buttons to deactivate Learn Mode.

Note:

When a MIDI controller is assigned to the Bypass control, moving the controller above the mid-point of its learned range engages Bypass. Moving the controller below the mid-point range disengages Bypass. When a MIDI controller has been assigned to the Tap control, moving the controller above the mid-point of its learned range will "tap" the control as if the Tap button had been pressed.

6-5

Image 97
Contents Page Important Safety Instructions Communications Notice Introduction System Mode English Instrucciones DE Seguridad Italiano Importanti Norme DI Sicurezza Vii Viii US Important User Information DE Wichtige Benutzerinformation ES Información importante para el usuario FR Important Informations Utilisateur IT Importanti informazioni per l’utente PT Informações Importantes ao usuário Getting Started About the MPX Getting StartedHighlights Input Trim Front Panel OverviewEdit Pages SystemPower Tap/CancelEdit Knobs StoreFront Panel Display Input/OVL IndicatorInput Level Meters Bank Name Routing ConfigurationEdit Knobs 1 to TempoProvides power to the unit with the supplied power AC Input ConnectorRear Panel Overview CordAnalog OUTPUTs Pdif in and OUTAnalog INPUTs Footswitch Connecting the UnitTypical Connections to a Console Input Setting Audio LevelsOutput Basic Operation Selecting and Loading Programs Basic OperationEditing Programs Adjust ParameterStoring Programs Compressor Audio TAP TAP Tempo Matching RhythmBypass Global TempoSystem Mode Parameter Settings System Mode FunctionsRestore Default Commands Parameter Settings Midi Dumps Settings if applicableOutput Level ParametersInput Source Clock SourceBypass Mode Dry, Full Mute, Input Mute Mix Mode Program, GlobalProgram Load Mode Tempo Mode Program, GlobalMidi Clock Enabled, Disabled Midi Patches Enabled, DisabledOperating Mode Normal, Demo, Locked Midi Channel Off, 1 to 16, OmniAuto Load Enabled, Disabled Memory Protect Enabled, DisabledDisplay Brightness Dump User Bank Midi DumpsDump Current Program Dump System DataClear User Bank Restore Default CommandsFactory Init Program Descriptions Single Programs Plate Plate Programs Adjust TapGATE/INV Gate/Inv Programs Adjust TapHall Hall Programs Adjust TapChamber Chamber Programs Adjust TapAmbience Ambience Programs Adjust TapRoom Room Programs Adjust TapTremolo Tremolo Programs Adjust TapRotary Rotary Programs Adjust TapChorus Chorus Programs Adjust TapFlange Flange Programs Adjust TapDetune Detune Programs Adjust TapPitch Pitch Programs Adjust TapDLY/EKO Dly/Eko Programs Adjust Tap Special FX Special FX Programs Adjust TapStereo Stage MSplit Dly, MSplit Rvb Dual ProgramsDual Mono EFX BAL Pitch DelayFLNG-DLY Flng-Dly Programs Adjust Tap RoutingPCH-DLY Pch-Dly Programs Adjust Tap RoutingCHOR-DLY Chor-Dly Programs Adjust Tap RoutingDLY-RVB Dly-Rvb Programs Adjust Tap RoutingFlng-Rvb Programs FLNG-RVBTap Routing PCH-RVB Pch-Rvb Programs Adjust Tap RoutingCHOR-RVB Chor-Rvb Programs Adjust Tap RoutingMsplit DLY MSplit Dly Programs Adjust Tap RoutingMsplit RVB MSplit Rvb Programs Adjust Tap RoutingProgram Descriptions Dual Mono Dual Mono Programs Adjust Tap RoutingCmprssr Comprssr Programs Adjust TapPeak Expansion DynamicsExpThrsh ExpLvl 0dB to 5.89dBCompression Level Meters Tape SaturationSaturation Off, Modern, Vintage Gain Min, 1 to 30, MaxPeak Expansion Meter Typical Mastering Dynamics Control AdjustmentInput Meter Gain Reduction MeterLIVE-FOH Front of House Typical Mastering Dynamics Control AdjustmentLive-FOH Programs Adjust Tap Parameter Descriptions Parameter Graphics Parameter DescriptionsParameter Descriptions Parameter Glossary Depth CmpRels To 250msecDiffusion Dly Fbk To 100%Drum Dep To 100% DlyTapLvlDrum Res Duration 140 to 700msHorn Dep To 100% HighSlope and LowSlopeHorn Res IntrvlPreDelay 0ms to 1.198sec Phase To 270degMix Dry, 1 to 99%, Wet MstrRate To 100%Res 1 Rate To 50.05Hz RvbLvlShape ResonancSpeed 1 SpeedSpread Sweep To 100msWavform Setting DescriptionWidth Midi Operation Midi Channel Assignment Learn ModeMidi Program Banks Program Change Messages Loading ProgramsContinuous Controllers Activating Bypass or TAP FunctionsMidi Operation Midi Clock Sysex Messages Function Transmitted Recognized Remarks Midi Implementation ChartYes Appendix Appendix SpecificationsDeclaration of Conformity Index Index MPX Limited Warranty Customer Support Dry Tracks Total Time