ClearOne comm AP400 operation manual Refsel, Preset

Page 67

Appendices ~ Appendix E: Serial Commands

PP

This command changes or reports back the state of the phantom power for a microphone.

[DEVICE] PP <CH> <X>

63

REFSEL

This command selects or returns the output to be used as the EC Reference and PA (speaker output).

[DEVICE] REFSEL <X> <OUTPUT>

Explanation

 

Explanation

 

<CH>

 

<X>

 

CH= 1-4

Parameter to apply to the specified

X=1

Parameter to select the EC

 

microphone channel

 

Reference and PA (speaker

CH= *

Parameter to apply command to all microphone

 

output)

 

channels

X=2

Parameter to select the G-Link

<X>

 

 

EC Ref bus

X=0

Parameter to set the state to OFF

<OUTPUT>

 

X=1

Parameter to set the state to ON

OUTPUT=1-4

Parameter to select 1-4 as the

X=Null

Parameter to return the current state

 

EC reference and PA (speaker

 

 

 

output)

Return Values

OUTPUT=A-D

Parameter to select A-D as the

The command will return the updated condition (On=1, Off=0) of

 

EC reference and PA (speaker

the phantom power in the same format as the command.

 

output)

 

 

OUTPUT=E

Parameter to select G-Link EC

PRESET

 

 

Ref bus as the EC Reference and

 

 

PA (speaker output)

This command selects or reports the current preset configuration

OUTPUT=F

Parameter to select none

OUTPUT=Null

Parameter to return the EC

used by the AP400.

 

reference and PA (speaker

 

 

 

[DEVICE] PRESET <X>

 

output) value

Explanation

<X>

X=1-6

Sets the preset to the number specified

X=Null

Parameter to return the current preset

Return Values

The command will return the current preset. If the command changed the preset, the updated preset is returned.

Return Values

The command will return the updated condition of the reference and PA (speaker output) select in the same format as the command.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Image 67
Contents AP400 Audio Conferencing System AP400 Installation ClearOne Part No July 2002 Rev Iii Table of ContentsOperation AP-Ware SoftwareAppendices Product Overview IntroductionFeatures ClearOne Communications EuMEA GmbH Professional Services GroupSales and Customer Service Technical SupportControls and Connections UnpackingFront panel Introduction ~ Controls and Connections Rear panelLink bus Link NetworkNOM Introduction ~ G-Link Networking BusLink EC Reference bus Control busTechnical Services Group ~ 1-800-283-5936 USA ~ Equipment Requirements AP400 installation diagram Hardware SetupInstallation ~ Hardware Setup Connecting the unitTo connect the AP400 To create a G-Link network Installation ~ Networking UnitsNetworking Units Link connectionsDevice types Mixer modeDevice IDs To set the device IDErrors To set mixer modeEC reference Menu trees Installation ~ LCD ProgrammingSwitching from one main menu category to another LCD ProgrammingLCD menu tree Adjusting a valueSet passcode Select presetSystem parameters Lock panelGate parameters Mixer modeDevice ID Unit IDFirst mic priority Last Mic ModeGate Ratio Hold Time Off AttenuationCombination Channels Decay RateManual Ambient To determine ambient levelInstallation ~ LCD Programming RS-232 Input parameters Installation ~ LCD Programming TelcoInputs Chairman Mic Phantom PowerHigh-Pass Filter EQ StatusSubbus Echo cancellerNLP adjust Inputs A-D, TelcoRouting parameters Output parametersOutput 1-4, Output A-D, Telco Link X-Z buses Installation ~ LCD Programming SubbusEC reference and PA Slave unit Link referenceMeter parameters Default MeterInputs, Outputs, ERL/TERL, and ERLE/TERLE Installation ~ Worksheet AP-Ware software requirements Description64MB RAM To install AP-Ware Installing AP-WareMuting Controlling the volumeTo adjust the volume Front PanelInstructions Telco InterfaceTo make and disconnect a call To mute or unmute an outputOperation ~ Controllers Other telco optionsControllers Custom control through DB-25 portTouch panel control Appendices Appendix a SpecificationsWarranty Appendix B Warranty and ComplianceThis warranty is void if FCC Part 15 Compliance Appendices ~ Appendix B Warranty and ComplianceFCC Part 68 Compliance Industry Canada Compliance Safety Information Control/Status port pinout Appendix C Connector PinoutsAppendices ~ Appendix C Connector Pinouts RS-232 COM DCE port pinoutAccessory ClearOne Part Number Appendix D AccessoriesAppendix E Serial Commands Appendices ~ Appendix D AccessoriesDevice Command SyntaxError Codes MrefFigure E.1. AP400 Serial Commands Appendices ~ Appendix E Serial CommandsReturn Values Serial Command Parameters ExplanationsAamb ExplanationCH= A-D AGCDevice AD Device AGC CHChairo AmblvlBaud BYEDial DecayDfltm ERL ErleFMP FlowFPP Example GainExamples Microphone gating keyHook GmodeGratio HoldLVL HookdLFP LMOMdmode MasterMEQ Minit MHPMline Input Input word assignment MmaxMpass MtrxOUTPUTMIXNote OutputmixReturn Values Device Mute CH W Device NLP CH Mute NLP=NULL PAA NOMOffa NullExample Preset Refsel PresetReturn Value RingRxrd TamodeTout TerlTerle UIDFigure F.1. Routing matrix worksheet Appendix F WorksheetsFigure F.2. Programming worksheet Appendices ~ Appendix F WorksheetsFigure F.3. Audio flow block diagram DSP IndexIndex ~ P-Z