ClearOne comm AP400 operation manual Amblvl, Baud, Bye, Chairo

Page 52

48

Appendices ~ Appendix E: Serial Commands

AMBLVL

This command changes or reports back the setting of the fixed ambient level for each AP400. This value is only used if adaptive ambient is not enabled.

[DEVICE] AMBLVL <X>

Explanation

<X>

X=0 to -70 Parameter to set the ambient level (in dB)

X=Null

Parameter to return the ambient level

Return Values

The command will return the updated ambient level for the selected AP400 in the same format as the command.

BAUD

This command selects or returns the baud rate for the RS-232 port on the AP400.

[DEVICE] BAUD <X>

Explanation

<X>

X=1

Selects 9,600 baud (bps) rate

X=2

Selects 19,200 baud (bps) rate

X=3

Selects 38,400 baud (bps) rate

X=Null

Parameter to return the baud (bps) rate

Return Values

The command will return the updated condition (1=9,600 baud, 2=19,200 baud, 3=38,400 baud) of the RS-232 baud rate in the same format as the command.

BYE

This command immediately enables password protection when modem mode is active.

[DEVICE] BYE

Note: This command is applicable only to the unit that is connected through the RS-232 port.

CHAIRO

This command changes or reports back the state of the chairman override for a microphone channel

[DEVICE] CHAIRO <CH> <X>

Explanation

<CH>

CH= 1-4

Parameter to apply to the specified

 

microphone channel

CH= *

Parameter to apply command to all

 

microphone channels

<X>

 

X=0

Parameter to set the state to OFF

X=1

Parameter to set the state to ON

X=2

Parameter to toggle the state from one state to

 

the other (regardless of current state)

X=Null

Parameter to return the current state

Return Values

The command will return the updated condition (On=1, Off=0) of the chairman override in the same format as the command.

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Image 52
Contents AP400 Audio Conferencing System AP400 Installation ClearOne Part No July 2002 Rev Table of Contents IiiOperation AP-Ware SoftwareAppendices Introduction Product OverviewFeatures Professional Services Group Sales and Customer ServiceTechnical Support ClearOne Communications EuMEA GmbHControls and Connections UnpackingFront panel Rear panel Introduction ~ Controls and ConnectionsLink Network Link busIntroduction ~ G-Link Networking Bus Link EC Reference busControl bus NOMTechnical Services Group ~ 1-800-283-5936 USA ~ Equipment Requirements Hardware Setup AP400 installation diagramInstallation ~ Hardware Setup Connecting the unitTo connect the AP400 Installation ~ Networking Units Networking UnitsLink connections To create a G-Link networkMixer mode Device IDsTo set the device ID Device typesErrors To set mixer modeEC reference Installation ~ LCD Programming Switching from one main menu category to anotherLCD Programming Menu treesAdjusting a value LCD menu treeSelect preset System parametersLock panel Set passcodeMixer mode Device IDUnit ID Gate parametersFirst mic priority Last Mic ModeGate Ratio Off Attenuation Hold TimeDecay Rate Manual AmbientTo determine ambient level Combination ChannelsInstallation ~ LCD Programming RS-232 Input parameters Installation ~ LCD Programming TelcoInputs Phantom Power High-Pass FilterEQ Status Chairman MicEcho canceller NLP adjustInputs A-D, Telco SubbusRouting parameters Output parametersOutput 1-4, Output A-D, Telco Link X-Z buses Installation ~ LCD Programming SubbusEC reference and PA Link reference Slave unitMeter parameters Default MeterInputs, Outputs, ERL/TERL, and ERLE/TERLE Installation ~ Worksheet AP-Ware software requirements Description64MB RAM Installing AP-Ware To install AP-WareControlling the volume To adjust the volumeFront Panel MutingTelco Interface To make and disconnect a callTo mute or unmute an output InstructionsOther telco options ControllersCustom control through DB-25 port Operation ~ ControllersTouch panel control Appendix a Specifications AppendicesWarranty Appendix B Warranty and ComplianceThis warranty is void if FCC Part 15 Compliance Appendices ~ Appendix B Warranty and ComplianceFCC Part 68 Compliance Industry Canada Compliance Safety Information Appendix C Connector Pinouts Appendices ~ Appendix C Connector PinoutsRS-232 COM DCE port pinout Control/Status port pinoutAppendix D Accessories Appendix E Serial CommandsAppendices ~ Appendix D Accessories Accessory ClearOne Part NumberCommand Syntax Error CodesMref DeviceAppendices ~ Appendix E Serial Commands Figure E.1. AP400 Serial CommandsSerial Command Parameters Explanations AambExplanation Return ValuesAGC Device ADDevice AGC CH CH= A-DAmblvl BaudBYE ChairoDial DecayDfltm Erle ERLFMP FlowFPP Gain ExamplesMicrophone gating key ExampleGmode GratioHold HookHookd LFPLMO LVLMdmode MasterMEQ Minit MHPMline Mmax MpassMtrx Input Input word assignmentOUTPUTMIXNote OutputmixReturn Values Device Mute CH W Device NLP CH Mute NLP=NULL NOM OffaNull PAAExample Preset Preset RefselRing RxrdTamode Return ValueTerl TerleUID ToutAppendix F Worksheets Figure F.1. Routing matrix worksheetAppendices ~ Appendix F Worksheets Figure F.2. Programming worksheetFigure F.3. Audio flow block diagram Index DSPIndex ~ P-Z