Installation ~ LCD Programming | 27 |
Subbus
The AP400 is equipped with one internal
Figure 2.20. Default routing matrix
G-Link X-Z buses
See page 7 for a description of this submenu.
EC reference and PA
The EC reference tells the microphones which output will be used as the sample reference for echo cancellation. EC REF references Output D (typically used for connection to an external amp speaker). A unit will support one common EC reference for all four microphones (as shown in Figure 2.21). Note that the PA output follows the settings for the EC Ref. This is because any audio being sent to a speaker must be used as EC Ref for Echo Cancellation to work properly.