Napoleon Fireplaces GD82NT-PA Minimum Enclosure Clearances, Non-combustible fireplace finishing

Page 17

MINIMUM ENCLOSURE CLEARANCES

Minimum clearance to combustible construction from fireplace and vent surfaces:

Combustible framing:

-0“ to stand-offs

Non-combustible fireplace finishing:

-4“ from the sides of fi replace opening

-22 3/8 “ to the top of fi replace opening

Combustible fireplace finishing:

-0“ to rear and sides

-2” all around the vent pipe

-22 1/2 “ recessed depth

-72“ from bottom of unit to enclosure top

-72” from bottom of unit to ceiling

FIGURE 32

17

HORIZONTAL VENT SECTIONS: A minimum clearance of 2” all around the vent pipe on all horizontal runs to combustibles is required. Use fi restop spacer W010-1799 (supplied).

VERTICAL VENT SECTIONS: A minimum of 1” all around the vent pipe on all vertical runs to combustibles is required except for clearances in fi replace enclosures. Use fi restop spacer W500-0096 (not supplied).

!WARNING

Facing and/or finishing material must never overhang into the fireplace opening.

Do not distort or force the frame kit components.

When using a rough finish material (i.e.; stone), maintain a ¼” - ½” border from the framing

components.

W415-0665 / B / 02.11.08

Image 17
Contents Installation Operation Instructions Table of Contents W415-0665 / B Installation Overview Fireplace DimensionsGeneral Instructions Supplier VentingElbow Vent Length Values Horizontal TerminationDefinitions = .03 four 90 elbows 90 = .03360 90 = 8.1 ft = .03 two 90 elbows 90 = .03180 90 =Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Minimum AIR Terminal Location Clearances Installation Wall and Ceiling Protection Using Flexible Vent Components Using Rigid Vent Components Atención Minimum Enclosure Height Combustible fireplace finishing Minimum Enclosure ClearancesNon-combustible fireplace finishing Electrical Schematic Hard Wiring ConnectionElectrical Connection Minimum Mantel and Enclosure ClearancesDoor Removal FinishingLOG Shipping Bracket StepGlowing Embers LOG PlacementBurner and Valve Replacement GLASS/DOOR ReplacementBlower Replacement Operation With a clean dry clothGeneral Transmitter Layout Fireplace Operation Bulb with bare fingers, protectHand Held Remote Operations Temperature DisplaySmart Thermostat Flame HeightFAN Speed LOW Battery / Manual BypassChild Proof Function Remote Auxiliary OutletWhat to do if YOU Smell GAS Operating InstructionsLighting Instructions To Turn OFF GASPilot Burner Adjustment AdjustmentsFlame Characteristics Venturi AdjustmentReplacements W415-0665 / B Symptom Problem Test Solution Trouble Shooting GuideThemostat or switch is de Fireplace Service History W415-0665 / B