Napoleon Fireplaces GD82NT-PA Hand Held Remote Operations, Temperature Display, Smart Thermostat

Page 23

HAND HELD REMOTE OPERATIONS

1.Press the ON/OFF key on the transmitter, it controls all functions of the remote. The transmitter display will show all active icons on the screen. At the same time the receiver turns on the main burner and a single “beep” from the receiver will confi rm reception of the command.

2.Press the ON/OFF key on the transmitter. The transmitter LCD display will only show the room temperature and icon. At the same time the receiver will turn the burner off and the appliance burner turns off. A single “beep” from the receiver confi rms reception of the command.

FIGURE 58

TEMPERATURE DISPLAY

1.With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same time to change the temperature from Fahrenheit to Celsius.

2.Check the LCD screen on the Transmitter to verify that a C or F is visible to the right of the Room Temperature display.

With the thermostat in the off mode, the flame height may be chosen and the main burner left on, regardless of the room temperature. To turn off the flame, either turn off the on/off key or reduce fl ame height to the off position.

23

1.Press the Thermostat Key. The LCD display on the Transmitter

will show that the room is“ON” and the set temperature is now displayed.

2.To adjust the set temperature, press the Up/Down Arrow Keys until the desired set temperature is displayed on the LCD screen of the Transmitter.

SMART THERMOSTAT

The Smart Thermostat function adjusts the fl ame height according to the difference between the set temperature and the actual room temperatures. As the room temperature gets closer to the set point the Smart Function will automatically adjust the fl ame down.

FIGURE 62

1.Press the thermostat key unit the word “SMART” appears to the right of the temperature bulb graphic.

2.To adjust the set temperature, press the Up/Down arrow keys until the desired set temperature is displayed on the LCD screen at the Transmitter.

FLAME HEIGHT

The remote control has six (6) fl ame levels. With the system on and the fl ame level at the maximum, press the Down Arrow Key once and it will reduce the fl ame height by one step until the fl ame is turned off.

The Up Arrow Key will increase the fl ame height each time it is pressed. If the Up Arrow Key is pressed while the system is on but the fl ame is off, the flame will come on the high position. A single “beep” will confi rm reception of the command.

FIGURE 59

FIGURE 60

ROOM THERMOSTAT

The remote control can operate as a room thermostat. The thermostat can be set to a desired temperature to control the comfort level in the room.

FIGURE 61

FIGURE 63

FIGURE 64

Flame OFF

Flame at level 1

FIGURE 65

FIGURE 66

Flame at level fi ve

Flame at “HI” level six

W415-0665 / B / 02.11.08

Image 23
Contents Installation Operation Instructions Table of Contents W415-0665 / B Installation Overview Fireplace DimensionsGeneral Instructions Supplier VentingElbow Vent Length Values Horizontal TerminationDefinitions = .03 four 90 elbows 90 = .03360 90 = 8.1 ft = .03 two 90 elbows 90 = .03180 90 =Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Minimum AIR Terminal Location Clearances Installation Wall and Ceiling Protection Using Flexible Vent Components Using Rigid Vent Components Atención Minimum Enclosure Height Combustible fireplace finishing Minimum Enclosure ClearancesNon-combustible fireplace finishing Minimum Mantel and Enclosure Clearances Hard Wiring ConnectionElectrical Schematic Electrical ConnectionStep FinishingDoor Removal LOG Shipping BracketGlowing Embers LOG PlacementBurner and Valve Replacement GLASS/DOOR ReplacementBlower Replacement Bulb with bare fingers, protect With a clean dry clothOperation General Transmitter Layout Fireplace OperationFlame Height Temperature DisplayHand Held Remote Operations Smart ThermostatRemote Auxiliary Outlet LOW Battery / Manual BypassFAN Speed Child Proof FunctionTo Turn OFF GAS Operating InstructionsWhat to do if YOU Smell GAS Lighting InstructionsVenturi Adjustment AdjustmentsPilot Burner Adjustment Flame CharacteristicsReplacements W415-0665 / B Symptom Problem Test Solution Trouble Shooting GuideThemostat or switch is de Fireplace Service History W415-0665 / B