Napoleon Fireplaces GD82NT-PA, GD82PT-PA manual Replacements

Page 27

27

REPLACEMENTS

Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon® dealer or distributor.

When ordering replacement parts always give the following infor- mation:

1.MODEL & SERIAL NUMBER OF FIREPLACE

2.INSTALLATION DATE OF FIREPLACE

3.PART NUMBER

4.DESCRIPTION OF PART

5.FINISH

FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.

*IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR FURTHER INFORMATION, CONTACT YOUR NAPOLEON® DEALER.

!WARNING

Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury.

REPLACEMENT PARTS

#PART NO. DESCRIPTION

1 W135-0267

#1 - REAR LOG

2W135-0268 #2 - MIDDLE LOG

3

W135-0269

#3 - RIGHT LOG

4

W135-0270

#4 - LEFT LOG

5

W135-0273

#5 - LEFT STICK

6W135-0274 #6 - RIGHT STICK

7

GL-654

LOG SET ASSEMBLY

8*

W390-0002

DOOR LATCH (EA)

9W725-0047 NATURAL GAS VALVE - MODULATING

9W725-0048 PROPANE GAS VALVE - MODULATING

10 W455-0017

NATURAL GAS ORIFICE #42

10W455-0003 PROPANE GAS ORIFICE #54

11W680-0005 THERMOCOUPLE **

12W240-0005 ELECTRODE C/W LEAD

13W680-0004 THERMOPILE

14W010- 1194 NATURAL GAS PILOT ASSEMBLY

14W010- 1201 PROPANE GAS PILOT ASSEMBLY

15W455-0070 NG PILOT INJECTOR

15

W455-0068

LP PILOT INJECTOR

16*

W385-0245

NAPOLEON® LOGO

17*

W562-0008

DOOR GASKET (100 INCHES)

18

W100-0087

BURNER

19

GD 552

BLOWER

20

W660-0041

SPARK SWITCH

21

W660-0071

REMOTE TRANSMITTER

22

W660-0070

REMOTE RECEIVER

23W190-0017 DC SPARK UNIT CONTROL

24W300-0067 ACCENT LIGHT GLASS

25 W387-0006

ACCENT LAMP

26W750-0107 ACCENT LIGHT WIRE

27W290-0080 ACCENT LENSE GASKET

28*

W361-0027

INSULATION SLEEVE

29*

W475-0401

PANEL, REAR FIBRE

30*

W475-0402

PANEL, RIGHT FIBRE

31*

W475-0403

PANEL, LEFT FIBRE

32

W225-0171

DOOR

33*

W300-0082

GLASS

34*

W500-0205

RESTRICTOR

35

W010-1799

FIRESTOP SPACER

36W660-0069 FAN CONTROL MODULE

!WARNING

**WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.

FLEXIBLE VENT KITS

GD220 (5 FT)

37*

W010-0397

4” FLEXIBLE VENT PIPE

 

 

- (5 FT) C/W SPACERS

37*

W410-0017

7” FLEXIBLE VENT PIPE - (5 FT)

GD330 (10 FT)

38* W010-0300 4” FLEXIBLE VENT PIPE

 

 

- (10 FT) C/W SPACERS

 

38*

W410-0018

7” FLEXIBLE VENT PIPE - (10 FT)

 

39*

W010-0370

WALL SUPPORT ASSEMBLY

 

 

 

 

 

 

 

TERMINAL KITS

 

40

PERISCOPE

 

- GD201

41

WALL TERMINAL KIT (ROUND)

- GD222R

41

WALL TERMINAL KIT

-GD222

 

ROOF TERMINAL KITS

 

42*

1/12 TO 7/12 PITCH

- GD110

43*

8/12 TO 12/12 PITCH

- GD111

44*

FLAT ROOF

 

- GD112

45*

W490-0073

4/7 INNER/OUTER SLEEVE

 

46

W670-0006

4/7 TERMINAL

 

47

W170-0086

STORM COLLAR

 

48

W010-0453

ROOF SUPPORT

 

49W263-0065 / ROOF FLASHING FLAT

W263-0066 / 1/12 TO 7/12 FLASHING

W263-0067 8/12 TO 12/12 FLASHING

 

 

ACCESSORIES

50*

W573-0007

HI-TEMP SEALANT

51*

GD501

HEAT GUARD

52

GA-566

HOT AIR DISTRIBUTION KIT

53

GA-72

HOT AIR EXHAUST KIT

54

GA-70

EXTENSION KIT, 5FT FLEX VENT

55*

W010-0370

WALL SUPPORT ASSEMBLY

56*

W175-0001

4” COUPLER

57*

W175-0013

7” COUPLER

58*

W175-0239

CONVERSION KIT - NG TO LP

59*

W175-0240

CONVERSION KIT - LP TO NG

60

GD811-KT

HERRINGBONE/SANDSTONE BRICK KIT

61

W135-0148

ANDIRON

62*

GD812-KT

REFRACTORY PANEL KIT

63

RFK82

RECTANGLE FACING KIT

64

AFK82

ARCHED FACING KIT

65*

RFK82WI

WROUGHT IRON FACING KIT

66

W135-0271

ANDIRON (OBELISK)

W415-0665 / B / 02.11.08

Image 27
Contents Installation Operation Instructions Table of Contents W415-0665 / B Installation Overview Fireplace DimensionsGeneral Instructions Supplier VentingHorizontal Termination DefinitionsElbow Vent Length Values = .03 four 90 elbows 90 = .03360 90 = 8.1 ft = .03 two 90 elbows 90 = .03180 90 =Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Minimum AIR Terminal Location Clearances Installation Wall and Ceiling Protection Using Flexible Vent Components Using Rigid Vent Components Atención Minimum Enclosure Height Minimum Enclosure Clearances Non-combustible fireplace finishingCombustible fireplace finishing Minimum Mantel and Enclosure Clearances Hard Wiring ConnectionElectrical Schematic Electrical ConnectionStep FinishingDoor Removal LOG Shipping BracketGlowing Embers LOG PlacementGLASS/DOOR Replacement Blower ReplacementBurner and Valve Replacement Bulb with bare fingers, protect With a clean dry clothOperation General Transmitter Layout Fireplace OperationFlame Height Temperature DisplayHand Held Remote Operations Smart ThermostatRemote Auxiliary Outlet LOW Battery / Manual BypassFAN Speed Child Proof FunctionTo Turn OFF GAS Operating InstructionsWhat to do if YOU Smell GAS Lighting InstructionsVenturi Adjustment AdjustmentsPilot Burner Adjustment Flame CharacteristicsReplacements W415-0665 / B Symptom Problem Test Solution Trouble Shooting GuideThemostat or switch is de Fireplace Service History W415-0665 / B