Napoleon Fireplaces GD82NT-PA, GD82PT-PA manual GLASS/DOOR Replacement, Blower Replacement

Page 21

21

SERVICING / REPLACEMENTS

GLASS/DOOR REPLACEMENT

The glass door is secured at the top front edge of the fireplace. Pull the latch forward then lift hook out from slot in the door. Tilt door forward then lift out from retainer along the bottom edge of the fi replace.

1. Place the door frame face down careful not to scratch the paint.

2. Center the gasketed glass inside the door frame with the thick side of the gasket facing up.

3. Bend the glass retainers located along the edge of the door frame over the gasket holding the glass in place. Careful not to break the glass.

FIGURE 48

NOTE: Care must be tak- en when removing and disposing of any broken glass or damaged components.

Be sure to vacuum up any broken glass from inside the fi replace before operation.

BLOWER REPLACEMENT

Your comes equipped with a heat circulating blower. The blower is pre-wired and is controlled by the remote control sup- plied with the unit.

Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy.

1.Turn off the power to the fi replace.

2. Turn off the gas valve.

FIGURE 49

BLOWER

MOUNTING PLATE

REMOVE 4 SCREWS

3.Remove the glass door, logs, rear log supports, brick panels, air defl ector, burner assy, panel support, panel support bracket.

4.The blower mounting plate can now be removed. Remove the four screws that secure the plate to the fi rebox base.

5.The blower is secured to the fi rebox. Disconnect the wire connec- tors before attempting to remove the blower from the fi rebox.

6.Remove the two screws securing the blower and lift through blower access opening.

Note: When re-installing the replacement blower, it will be necessary to replace the gasket (W290-0104) on the blower mounting plate.

FIGURE 50

BURNER AND VALVE REPLACEMENT

1a. Rectangular Front Removal

Pull on the top of the optional front away from the fi replace until the male portion of the latch disengages. Tilt forward slightly and lift from the 2 shoulder screws near the bottom.

1b. Heritage and Wrought Iron Front Removal

Turn the head of each turn button from a horizontal position to verti- cal. Allow the front to tilt forward slightly and lift from the 2 shoulder screws near the bottom front. Note: Fronts are heavy so when the second turn button is turned the front will want to fall forward. See Figure 51.

2. Control Panel Removal

Tilt control panel away from the door and lift from slots. See Figure 53.

FIGURE 51

3.Turn Power and Gas off to the unit.

4.Door Removal.

See door removal section.

5. Burner Removal

Start by removing the logs being careful since the logs may still be warm. Remove the 2 screws holding the air defl ector (Figure 52a) then remove the 3 screw holding the burner (Figure 52b). Lift burner from fi rebox.

AIR

FIGURE 52a

 

DEFLECTOR

 

BURNER

FIGURE 52b

6.Remove the 5 screws securing the burner base. Once the gas has been disconnected, the valve train assembly will lift out. Service components as required.

REMOVE 2 SCREWS

W415-0665 / B / 02.11.08

Image 21
Contents Installation Operation Instructions Table of Contents W415-0665 / B Installation Overview Fireplace DimensionsGeneral Instructions Supplier VentingHorizontal Termination DefinitionsElbow Vent Length Values = .03 four 90 elbows 90 = .03360 90 = 8.1 ft = .03 two 90 elbows 90 = .03180 90 =Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Minimum AIR Terminal Location Clearances Installation Wall and Ceiling Protection Using Flexible Vent Components Using Rigid Vent Components Atención Minimum Enclosure Height Minimum Enclosure Clearances Non-combustible fireplace finishingCombustible fireplace finishing Electrical Schematic Hard Wiring ConnectionElectrical Connection Minimum Mantel and Enclosure ClearancesDoor Removal FinishingLOG Shipping Bracket StepGlowing Embers LOG PlacementGLASS/DOOR Replacement Blower ReplacementBurner and Valve Replacement Operation With a clean dry clothGeneral Transmitter Layout Fireplace Operation Bulb with bare fingers, protectHand Held Remote Operations Temperature DisplaySmart Thermostat Flame HeightFAN Speed LOW Battery / Manual BypassChild Proof Function Remote Auxiliary OutletWhat to do if YOU Smell GAS Operating InstructionsLighting Instructions To Turn OFF GASPilot Burner Adjustment AdjustmentsFlame Characteristics Venturi AdjustmentReplacements W415-0665 / B Symptom Problem Test Solution Trouble Shooting GuideThemostat or switch is de Fireplace Service History W415-0665 / B