Napoleon Fireplaces GD82NT-PA, GD82PT-PA manual Finishing, Door Removal, LOG Shipping Bracket, Step

Page 19
FIGURE 40

19

FINISHING

DOOR REMOVAL

Before the glass door can be removed, the optional front must be removed.

The glass door is secured to the top front edge of the firebox with two latches. Pull the handles of the latches forward, then lift the hooks out from the slots in the door frame to release the top of the door. Next, pivot forward until the top edge of the door clears the front of the fi replace. Next gripping the sides of the door lift the door out

from the retainer along the bottom of the door.

LOG SHIPPING BRACKET

FIGURE 38

FIGURE 37

LATCHES

GLASS

DOOR

OPTIONAL

RETAINER

FRONT

 

Before installing the logs, you must fi rst remove the log shipping brackets. Lift up to remove.

LOG SHIPPING

BRACKET

DECORATIVE BRICK PANEL INSTALLATION

Decorative panels may discolor after time.

1.Carefully remove the glass door and all logs. (Refer to the “FINISHING” section)

2.Remove the two screws holding the front portion of the rear air defl ector. Remove the pilot shield by removing the two screws as

illustrated. (Fig. 40)

STEP

#2

PILOT SHIELD

3.Remove the 3 screws holding the burner down and carefully remove the burner. (Fig. 41)

4.Install the right brick panel by sliding the bottom edge of the panel down the right fi rebox side then pivot the top edge of the panel into place against the fi rebox wall. Hold in place with the brick retainers.

(Fig. 41)

STEP

#3

FIGURE 42

5.Rest the bottom edge of the rear panel on top of the rear portion of the air defl ector at the back of the fi rebox and push into place. The rear panel is held in place when both side panels are in position.

6.Install the left brick panel using the same method described in step 4.

7.Replace

the burner, air defl ector, logs and glass door.

1 2 3

FIGURE 43

HERRINGBONE PATTERN ILLUSTRATED

Note: Due to the brittle material of the bricks, care must be

taken not to bend or force them into place.

Note: Refractory panels require a 24 hour curing period on a

low flame.

FIGURE 41

W415-0665 / B / 02.11.08

Image 19
Contents Installation Operation Instructions Table of Contents W415-0665 / B Installation Overview Fireplace DimensionsGeneral Instructions Supplier VentingDefinitions Horizontal TerminationElbow Vent Length Values = .03 four 90 elbows 90 = .03360 90 = 8.1 ft = .03 two 90 elbows 90 = .03180 90 =Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Minimum AIR Terminal Location Clearances Installation Wall and Ceiling Protection Using Flexible Vent Components Using Rigid Vent Components Atención Minimum Enclosure Height Non-combustible fireplace finishing Minimum Enclosure ClearancesCombustible fireplace finishing Minimum Mantel and Enclosure Clearances Hard Wiring ConnectionElectrical Schematic Electrical ConnectionStep FinishingDoor Removal LOG Shipping BracketGlowing Embers LOG PlacementBlower Replacement GLASS/DOOR ReplacementBurner and Valve Replacement Bulb with bare fingers, protect With a clean dry clothOperation General Transmitter Layout Fireplace OperationFlame Height Temperature DisplayHand Held Remote Operations Smart ThermostatRemote Auxiliary Outlet LOW Battery / Manual BypassFAN Speed Child Proof FunctionTo Turn OFF GAS Operating InstructionsWhat to do if YOU Smell GAS Lighting InstructionsVenturi Adjustment AdjustmentsPilot Burner Adjustment Flame CharacteristicsReplacements W415-0665 / B Symptom Problem Test Solution Trouble Shooting GuideThemostat or switch is de Fireplace Service History W415-0665 / B