GENERAL INSTRUCTIONS

This gas fireplace should be installed and serviced by a qualified installer to conform with local codes. Installation practices vary from region to region and it is important to know the specifics that apply to your area,

for example: in Massachusetts State:

The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert or gas log.

The appliance off valve must be a “T” handle gas cock.

The flexible connector must not be longer than 36 “.

The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.

A carbon monoxide detector is required in all rooms containing gas fired appliances.

WARNING: This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of Massachusetts.

In absence of local codes, install to the current CAN/CGA -B149 Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1, and NFPA 54 in the United States. Suitable for mobile home installation if installed in accordance with the current standard CAN/CSA Z240MH Series, for gas equipped mobile homes, in Canada or ANSI Z223.1 and NFPA 54 in the United States.

The fireplace and its individual shutoff valve must be discon- nected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The fireplace must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

When the fireplace is installed directly on carpeting, vinyl tile or other combustible material other than wood flooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth.

The optional heat circulating blower is supplied with a cord. If installed, the junction box must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 canadian electrical code in Canada or the ANSI/NFPA 70 national electrical code in the United States.

Provide adequate ventilation and combustion air.

Provide adequate accessibility clearance for servicing and operating the fireplace. Never obstruct the front opening of the fireplace.

Objects placed in front of the fireplace must be kept a minimum of 48” from the front face of the unit.

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! Maximum input is 26,000 BTU/hr for both natural gas and propane. When the fireplace is installed at elevations above 4,500ft, and in the absence of specific recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft. Maximum output for natural gas is 16150 BTU/hr at an efficiency of 62%; and 16150 BTU/hr for propane at an efficiency of 62%. Minimum inlet gas supply pressure is 4.5 “ water column for natural gas and 11 “ water column for propane. Maximum inlet gas pressure is 7 “ water column for natural gas and 13 “ water column for propane. Manifold pressure under flow conditions is

3.5“ water column for natural gas and 10 “ water column for propane.

This fireplace is certified to be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.

No external electricity (110 volts or 24 volts) is required for the gas system operation.

5

This fireplace is only for use with the type of gas indicated on the rating plate. This fireplace is not convertible for use with other gases, unless a certified kit is used.

Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected. Change in flame appearance from “HI” to “LO” is more evident in natural gas than in propane.

This fireplace is approved for bathroom, bedroom and bed-sitting

room installationsand is suitable for mobile home installation. The innerstainless steelWelookingSuggestfirebox backthatwillourdiscolourgas with

heat, turninga light brown,hearthstrawproductslike colour thatbeisinstalledto be consid- ered normal

and serviced by profession-

als who are certified in the We Suggest that our gas U.S. by the National Fire- hearth products be installed place Institute (NFI) as NFI and serviced by profession- Gas Specialists.

als who are certified in the

U.S. by the National Fire- CAREplaceOFInstituteGLASS(NFI) as NFI

Do not use abrasive cleanersGas toSpecialistsclean glass. .Buff lightly with a clean dry cloth.The glass is 3/16” ceramic glass available from your Napoleon® / Wolf Steel Ltd. dealer. Do not substitute materials. Clean theCAREglass afterOFthe GLASSfirst 10 hours of operation with a recommended gas fireplace glass cleaner. Thereafter clean as Do not use abrasive cleaners to clean glass. Buff lightly with a required. Do not clean glass when hot! If the glass is not kept clean dry cloth. The glass is 3/16” ceramic glass available from clean permanent discolouration and / or blemishes may result. your Napoleon® / Wolf Steel Ltd. dealer. Do not substitute

materials. Clean the glass after the first 10 hours of operation with

a recommended gas fireplace glass cleaner. Thereafter clean as required. Do not clean glass when hot! If the glass is not kept clean permanent discolouration and / or blemishes may result.

W415-0665 / B / 02.11.08

Image 5
Contents Installation Operation Instructions Table of Contents W415-0665 / B Installation Overview Fireplace DimensionsGeneral Instructions Supplier VentingElbow Vent Length Values Horizontal TerminationDefinitions = .03 four 90 elbows 90 = .03360 90 = 8.1 ft = .03 two 90 elbows 90 = .03180 90 =Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Minimum AIR Terminal Location Clearances Installation Wall and Ceiling Protection Using Flexible Vent Components Using Rigid Vent Components Atención Minimum Enclosure Height Combustible fireplace finishing Minimum Enclosure ClearancesNon-combustible fireplace finishing Electrical Schematic Hard Wiring ConnectionElectrical Connection Minimum Mantel and Enclosure ClearancesDoor Removal FinishingLOG Shipping Bracket StepGlowing Embers LOG PlacementBurner and Valve Replacement GLASS/DOOR ReplacementBlower Replacement Operation With a clean dry clothGeneral Transmitter Layout Fireplace Operation Bulb with bare fingers, protectHand Held Remote Operations Temperature DisplaySmart Thermostat Flame HeightFAN Speed LOW Battery / Manual BypassChild Proof Function Remote Auxiliary OutletWhat to do if YOU Smell GAS Operating InstructionsLighting Instructions To Turn OFF GASPilot Burner Adjustment AdjustmentsFlame Characteristics Venturi AdjustmentReplacements W415-0665 / B Symptom Problem Test Solution Trouble Shooting GuideThemostat or switch is de Fireplace Service History W415-0665 / B