Napoleon Fireplaces GD82PT-PA, GD82NT-PA manual = .03 two 90 elbows 90 = .03180 90 =

Page 8

8

HORIZONTAL TERMINATION

when (HT) > (VT)

Simple venting confi guration (only one 90° elbow)

FIGURE 7

See graph to determine the required verti- cal rise VT for the required horizontal run HT.

V1

= VT = 6 ft

H1

= 3 ft

H2

= 5 ft

HR

= H1 + H2 = 3 + 5 = 8 ft

HO

= .03 (two 90° elbows - 90°) = .03(180° - 90°) = 2.7

ft

 

HT

= HR + HO = 8 + 2.7 = 10.7 ft

HT + VT= 10.7 + 6 =16.7

Formula 1: HT < 4.2 VT

4.2VT = 4.2 x 6 = 25.2 ft

10.7< 25.2

Formula 2: HT + VT < 24.75 feet

16.7 < 24.75

Since both formulas are met, this vent confi guration is ac-

REQUIRED

VERTICAL

RISE IN

INCHES

VT

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

ceptable.

V1

Example 3:

 

 

 

 

90°

 

H4

 

 

 

 

 

 

 

H1

 

 

 

 

 

 

V2

 

 

 

 

 

 

 

 

 

H2 H3

90°

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 9

The shaded area within the lines represents acceptable values for HT and VT .

For vent confi gurations requiring more than one 90° elbow the following formulas apply:

Formula 1: HT < 4.2 VT

Formula 2: HT + VT < 24.75 feet

Example 2:

H1

H2

V1 90°

FIGURE 8

V1

= 4 ft

V2

= 1.5 ft

VT

= V1 + V2 = 4 + 1.5 = 5.5 ft

H1

= 2 ft

H2

= 1 ft

H3

= 1 ft

H4

= 1.5 ft

HR

= H1 + H2 + H3 + H4 = 2 + 1 + 1 + 1. 5 = 5.5 ft

HO

= .03 (four 90° elbows - 90°) = .03(360° - 90°) = 8.1 ft

HT

= HR + HO = 5.5 + 8.1 = 13.6 ft

HT + VT = 13.6 + 5.5 = 19.1 ft

Formula 1: HT < 4.2 VT

4.2VT = 4.2 x 5.5 = 23.1 ft

13.6< 23.1

Formula 2: HT + VT < 24.75 feet

19.1 < 24.75

Since both formulas are met, this vent configuration is

W415-0665 / B / 02.11.08

Image 8
Contents Installation Operation Instructions Table of Contents W415-0665 / B Fireplace Dimensions Installation OverviewGeneral Instructions Venting SupplierElbow Vent Length Values Horizontal TerminationDefinitions = .03 two 90 elbows 90 = .03180 90 = = .03 four 90 elbows 90 = .03360 90 = 8.1 ftVertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Minimum AIR Terminal Location Clearances Installation Wall and Ceiling Protection Using Flexible Vent Components Using Rigid Vent Components Atención Minimum Enclosure Height Combustible fireplace finishing Minimum Enclosure ClearancesNon-combustible fireplace finishing Hard Wiring Connection Electrical SchematicElectrical Connection Minimum Mantel and Enclosure ClearancesFinishing Door RemovalLOG Shipping Bracket StepLOG Placement Glowing EmbersBurner and Valve Replacement GLASS/DOOR ReplacementBlower Replacement With a clean dry cloth OperationGeneral Transmitter Layout Fireplace Operation Bulb with bare fingers, protectTemperature Display Hand Held Remote OperationsSmart Thermostat Flame HeightLOW Battery / Manual Bypass FAN SpeedChild Proof Function Remote Auxiliary OutletOperating Instructions What to do if YOU Smell GASLighting Instructions To Turn OFF GASAdjustments Pilot Burner AdjustmentFlame Characteristics Venturi AdjustmentReplacements W415-0665 / B Trouble Shooting Guide Symptom Problem Test SolutionThemostat or switch is de Fireplace Service History W415-0665 / B