Napoleon Fireplaces GD82NT-PA, GD82PT-PA manual Vertical Termination

Page 9

9

VERTICAL TERMINATION

when (HT) < (VT)

Example 4:

FIGURE 10

FIGURE 11

 

90°

V3

90°

 

 

V

H2

 

H1

2

90°

 

V1

 

 

90°

 

See graph to determine the required vertical rise VT for the required horizontal run HT.

REQUIRED VERTICAL

RISE IN FEET

VT

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

The shaded area within the lines represents acceptable values for HT and VT .

For vent confi gurations requiring more than zero 90° elbow (top exit) or one 90° elbow (rear exit), the following formulas apply:

Formula 1: HT < VT

Formula 2: HT + VT < 40 feet

V1

=5 ft

V2

=6 ft

V3

=10 ft

VT

= V1 + V2 + V3 = 5 + 6 + 10 = 21 ft

H1

=8 ft

H2

=2.5 ft

HR

= H1 + H2 = 8 + 2.5 = 10.5 ft

HO

= .03 (four 90° elbows - 90°)

 

= .03 (90 + 90 + 90 + 90 - 90) = 8.1 ft

HT

=HR + HO = 10.5 + 8.1 = 18.6 ft

HT + VT = 18.6 + 21 = 39.6 ft

Formula 1: HT < VT 18.6 < 21

Formula 2: HT + VT < 40 feet 39.6 < 40

Since both formulas are met, this vent configuration is acceptable.

W415-0665 / B / 02.11.08

Image 9
Contents Installation Operation Instructions Table of Contents W415-0665 / B Installation Overview Fireplace DimensionsGeneral Instructions Supplier VentingHorizontal Termination DefinitionsElbow Vent Length Values = .03 four 90 elbows 90 = .03360 90 = 8.1 ft = .03 two 90 elbows 90 = .03180 90 =Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Minimum AIR Terminal Location Clearances Installation Wall and Ceiling Protection Using Flexible Vent Components Using Rigid Vent Components Atención Minimum Enclosure Height Minimum Enclosure Clearances Non-combustible fireplace finishingCombustible fireplace finishing Electrical Schematic Hard Wiring ConnectionElectrical Connection Minimum Mantel and Enclosure ClearancesDoor Removal FinishingLOG Shipping Bracket StepGlowing Embers LOG PlacementGLASS/DOOR Replacement Blower ReplacementBurner and Valve Replacement Operation With a clean dry clothGeneral Transmitter Layout Fireplace Operation Bulb with bare fingers, protectHand Held Remote Operations Temperature DisplaySmart Thermostat Flame HeightFAN Speed LOW Battery / Manual BypassChild Proof Function Remote Auxiliary OutletWhat to do if YOU Smell GAS Operating InstructionsLighting Instructions To Turn OFF GASPilot Burner Adjustment AdjustmentsFlame Characteristics Venturi AdjustmentReplacements W415-0665 / B Symptom Problem Test Solution Trouble Shooting GuideThemostat or switch is de Fireplace Service History W415-0665 / B