Napoleon Fireplaces GD82NT-PA, GD82PT-PA manual Operating Instructions, What to do if YOU Smell GAS

Page 25

25

OPERATING INSTRUCTIONS

When lit for the fi rst time, the fireplace will emit a slight odor for a few hours. This is a normal temporary condition caused by the cur- ing of paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to suffi ciently ventilate the room.

After extended periods of non-operation such as following a vacation

or a warm weather season, the fi replace may emit a slight odor for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to suffi ciently ventilate the room.

Purge all gas lines with the glass door of the fireplace open. Assure that a continuous gas flow is at the burner before closing the door.

FOR YOUR SAFETY READ BEFORE LIGHTING:

A.This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B.Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor.

C.Use only your hand to turn the gas control knob / manual shut-off knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a qualifi ed service technician. Force or attempted re pair may result in a fi re or explosion.

D.Do not use this fi replace if any part has been under water. Immediately call a qualifi ed service technician to inspect the fi replace and replace any part of the control system and any gas control which has been under water.

WHAT TO DO IF YOU SMELL GAS

Do not touch any electric switch.

Do not use any phone in your building.

If you cannot reach your gas supplier, call the fi re department.

Turn off all gas to the fi replace.

Do not try to light any appliance.

Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s instructions.

FIGURE 74

GAS KNOB

LIGHTING INSTRUCTIONS

Warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Initial lighting of the pilot and main burners must be done with the glass door off.

Do not connect valve or wall switch to electricity. See installation instructions.

When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob it depressed slightly.

1. STOP! Read the safety information on the operating la- bel.

2.Turn off all electric power to the fi replace.

3.Turn the gas knob clockwise to off.

4.Wait 5 minutes to clear out any gas. If you smell gas, including near the fl oor, STOP! Follow “B” on the op- erating label. If you don’t smell gas, go to the next step.

5.If the fi replace is equipped with a fl ame adjustment valve, turn clockwise to off.

6.Find pilot located in front of the back log on the right side.

7.Turn gas knob counter-clocKwise to pilot.

8.This unit is equipped with an auto-spark. Depress and hold gas knob . Keep knob fully de pressed for one minute, then release. If pilot does not continue to burn repeat steps 3 through 7.

9.With pilot lit, turn gas knob counter-clockwise to on.

10.If equipped with fl ame adjustment valve, push and turn knob to high.

11.If equipped with remote on-off switch, main burner may not come on when you turn the valve to on or high. Remote switch must be in the on position to ignite burner.

12.Turn on all electric power to the fi replace.

FIGURE 75

SOLENOID PILOT

ON/OFF

KNOB

TO TURN OFF GAS

1.Turn off all electric power to the fi replace if service is to be performed.

2.For a complete shut-down procedure: push in gas control knob

slightly and turnclockwise to off. Do not force.

3.For a temporary shut-down procedure: set thermostat to low- est setting or remote switch to off. Press and turn the gas knob

clockwiseto pilot.

W415-0665 / B / 02.11.08

Image 25
Contents Installation Operation Instructions Table of Contents W415-0665 / B Installation Overview Fireplace DimensionsGeneral Instructions Supplier VentingDefinitions Horizontal TerminationElbow Vent Length Values = .03 four 90 elbows 90 = .03360 90 = 8.1 ft = .03 two 90 elbows 90 = .03180 90 =Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Minimum AIR Terminal Location Clearances Installation Wall and Ceiling Protection Using Flexible Vent Components Using Rigid Vent Components Atención Minimum Enclosure Height Non-combustible fireplace finishing Minimum Enclosure ClearancesCombustible fireplace finishing Electrical Schematic Hard Wiring ConnectionElectrical Connection Minimum Mantel and Enclosure ClearancesDoor Removal FinishingLOG Shipping Bracket StepGlowing Embers LOG PlacementBlower Replacement GLASS/DOOR ReplacementBurner and Valve Replacement Operation With a clean dry clothGeneral Transmitter Layout Fireplace Operation Bulb with bare fingers, protectHand Held Remote Operations Temperature DisplaySmart Thermostat Flame HeightFAN Speed LOW Battery / Manual BypassChild Proof Function Remote Auxiliary OutletWhat to do if YOU Smell GAS Operating InstructionsLighting Instructions To Turn OFF GASPilot Burner Adjustment AdjustmentsFlame Characteristics Venturi AdjustmentReplacements W415-0665 / B Symptom Problem Test Solution Trouble Shooting GuideThemostat or switch is de Fireplace Service History W415-0665 / B