Napoleon Fireplaces GD82PT-PA, GD82NT-PA manual LOG Placement, Glowing Embers

Page 20
FIGURE 45
FIGURE 44

20

LOG PLACEMENT

NOTE: Decorative brick panels must be installed before the logs.

See installation instructions supplied with the panel kit.

PHAZERTM logs, exclusive to Napoleon® Fireplaces, provide a unique and realistic glowing effect that is different in every installation.

FIGURE 39 a-f

1

1.Place the rear log #1 onto the locating studs along the back edge of the PHAZERAM- IC™ burner.

4.Place log #4 with the charred

branch facing inward. Position

4

the pin in log #4 into the hole on the right of log #2.

 

 

5. Place log #5 so the locating

 

 

 

hole on the bottom of the log

 

2. Position log #2 in the 2

 

sits on the screw and spacer.

5

locating holes behind the

 

 

 

andirons.

 

2

 

 

 

6. Finally, align the rectangular

 

3. Place log #3, with the

 

peg on log #6 with the notch

 

 

on the front right portion of

6

charred branch facing in-

3

ward. Position the pin in log

the burner.

 

#3 into the hole on the left of

the log #2.

GLOWING EMBERS

Glowing embers are NOT recommended. The burner has been

 

 

designed to achieve maximum glow without embers.

 

 

 

 

AFK / WI FACE KIT INSTALLATION

1. Attach screw and spacer as illustrated in (Fig. 44) to the bottom of both sides of the front housing.

SCREW

&

SPACER

2.Attach the face plate bracket provided to the top edge of the front housing using 2 #8 - 1/2” truss head screws as illustrated in (Fig. 45).

FIGURE 46

3.Lift and hook the faceplate over the spacers, and push the top of the faceplate back until it comes in contact with the base of the turn button. To secure the faceplate simply turn the head of the turn button to the horizontal position. (Fig. 47).

FIGURE 47

NOTE: A 1/4” gap must be maintained between the front and

all finishing material due to regular removal.

W415-0665 / B / 02.11.08

Image 20
Contents Installation Operation Instructions Table of Contents W415-0665 / B Fireplace Dimensions Installation OverviewGeneral Instructions Venting SupplierElbow Vent Length Values Horizontal TerminationDefinitions = .03 two 90 elbows 90 = .03180 90 = = .03 four 90 elbows 90 = .03360 90 = 8.1 ftVertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Minimum AIR Terminal Location Clearances Installation Wall and Ceiling Protection Using Flexible Vent Components Using Rigid Vent Components Atención Minimum Enclosure Height Combustible fireplace finishing Minimum Enclosure ClearancesNon-combustible fireplace finishing Hard Wiring Connection Electrical SchematicElectrical Connection Minimum Mantel and Enclosure ClearancesFinishing Door RemovalLOG Shipping Bracket StepLOG Placement Glowing EmbersBurner and Valve Replacement GLASS/DOOR ReplacementBlower Replacement With a clean dry cloth OperationGeneral Transmitter Layout Fireplace Operation Bulb with bare fingers, protectTemperature Display Hand Held Remote OperationsSmart Thermostat Flame HeightLOW Battery / Manual Bypass FAN SpeedChild Proof Function Remote Auxiliary OutletOperating Instructions What to do if YOU Smell GASLighting Instructions To Turn OFF GASAdjustments Pilot Burner AdjustmentFlame Characteristics Venturi AdjustmentReplacements W415-0665 / B Trouble Shooting Guide Symptom Problem Test SolutionThemostat or switch is de Fireplace Service History W415-0665 / B