Napoleon Fireplaces GD82NT-PA, GD82PT-PA manual Using Flexible Vent Components

Page 13
HIGH
TEMPERATURE SEALANT
INNER FLEXIBLE VENT PIPE
OUTER FLEXIBLE VENT PIPE
DO NOT CLAMP THE
FLEXIBLE VENT PIPE
FIGURE 22b
AIR
TERMINAL
CONNEC-
TOR
FIGURE 22a
ROOF SUPPORT
FIGURE 20
#10x2"
SCREWS

13

USING FLEXIBLE VENT COMPONENTS

FIGURE 19

ELBOW

SPACERS

!WARNING

Do not allow the inside vent pipe to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 1 1/4” air gap between the liner and the outer liner all around is required for safe operation. A spacer is required at the start, middle and end of each elbow to ensure this gap is maintained. Spacers are attached to the inner flexible vent pipe at predetermined intervals to maintain a 1 1/4" air gap to the outer flexible vent pipe. These spacers must not be removed.

For safe and proper operation of the fireplace, follow the venting

instructions exactly.

All inner exhaust and outer intake vent pipe joists may be sealed using either red RTV high temp silicone sealant or black high temp Mill Pac with the exception of the fireplace exhaust flue collar which must be sealed using Mill Pac (not supplied).

Use only approved flexible vent pipe kits marked:

“Wolf Steel Approved Venting” as identified by the stamp only on the 7” outer vent pipe.

Six inches (6”) is the minimum bend radius allowed for the seven inch (7”) diameter flexible vent pipe.

HORIZONTAL AIR TERMINAL INSTALLATION

Note: Direct vent terminals shall not be recessed

into a wall or

CAULKING

 

siding.

5"FLEX

1. Stretch the

4" diameter

PIPE

 

flexible vent pipe

8" FLEX PIPE

to the required

2" OVERLAP

length taking into

 

account the

HI-TEMP

additional length

SEALANT

needed for the finished wall surface. Slip the liner a minimum of 2" over the inner sleeve of the air terminal and secure with 3 #8 screws. Apply a heavy bead of the high temperature sealant W573-0007 (not supplied).

2.Using the 7” diameter flexible vent pipe, slide over the outer combustion air sleeve of the air terminal and secure with 3 #8 screws. Seal as before.

3.Insert the vent pipe through the firestop maintaining the required clearance to combustibles. Secure to the exterior wall and make weather tight by sealing with caulking W573-0002 (not supplied).

4.If more vent pipe needs to be used to reach the fireplace, couple them together as illustrated in (Fig. 20). The vent system

must be supported

HIGH TEMP

 

approximately every 3

SEALANT

#8 X 1/2” SELF DRILLING

feet for both vertical

 

SCREWS & WASHERS

 

4” COUPLER 7” COUPLER

and horizontal runs.

 

 

 

Use non-combusible

 

 

strapping to maintain

7” FLEX

7” FLEX PIPE

the minimum 1”

4” FLEX

clearance to combus-

PIPE

 

PIPE

tibles.

 

FIGURE 21

For optimum performance it is recommended that all horizontal runs have a minimum 1” rise per foot using flexible venting.

VERTICAL AIR TERMINAL INSTALLATION

1. Move the fireplace into position.

2.Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method

suitable to the authority having jurisdiction or the optional roof support.

3.Stretch the inner flexible vent pipe to the required length. Slip the liner a minimum of 2” over the inner vent pipe of the air terminal connector and secure with 3 #8 screws. Seal using a heavy bead of the high temperature sealant W573-0007 (not supplied).

4.Repeat using the outer

flexible vent pipe.

INNER

5. Thread the air terminal

PIPE

 

connector / pipe assembly

 

down through the roof. The air

 

terminal must be located

 

vertically and plumb. Attach the air terminal connector to the roof support, ensuring that the top of the air terminal is 16” above the highest point that it penetrates the roof. If the attic space is tight, we recom-

mend threading the Wolf Steel vent pipe collar or equivalent loosely onto the air terminal assembly as it is passed through the attic.

6. Remove nails from the shingles, above and to the

sides of the chimney. Place the flashing over the air terminal connector leaving a min. 3/4” of the air terminal connector showing above the top of the flashing. Slide the flashing underneath the sides and upper edge of the shingles. Ensure that the air terminal connector is properly centred within the flashing, giving a 3/4” margin all around. Fasten to the roof. Do not nail through the lower portion of the flashing. Make weather-tight by sealing with caulking. Where possible, cover the sides and top edges of the flashing with roofing material.

W415-0665 / B / 02.11.08

Image 13
Contents Installation Operation Instructions Table of Contents W415-0665 / B Installation Overview Fireplace DimensionsGeneral Instructions Supplier VentingDefinitions Horizontal TerminationElbow Vent Length Values = .03 four 90 elbows 90 = .03360 90 = 8.1 ft = .03 two 90 elbows 90 = .03180 90 =Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Minimum AIR Terminal Location Clearances Installation Wall and Ceiling Protection Using Flexible Vent Components Using Rigid Vent Components Atención Minimum Enclosure Height Non-combustible fireplace finishing Minimum Enclosure ClearancesCombustible fireplace finishing Electrical Schematic Hard Wiring ConnectionElectrical Connection Minimum Mantel and Enclosure ClearancesDoor Removal FinishingLOG Shipping Bracket StepGlowing Embers LOG PlacementBlower Replacement GLASS/DOOR ReplacementBurner and Valve Replacement Operation With a clean dry clothGeneral Transmitter Layout Fireplace Operation Bulb with bare fingers, protectHand Held Remote Operations Temperature DisplaySmart Thermostat Flame HeightFAN Speed LOW Battery / Manual BypassChild Proof Function Remote Auxiliary OutletWhat to do if YOU Smell GAS Operating InstructionsLighting Instructions To Turn OFF GASPilot Burner Adjustment AdjustmentsFlame Characteristics Venturi AdjustmentReplacements W415-0665 / B Symptom Problem Test Solution Trouble Shooting GuideThemostat or switch is de Fireplace Service History W415-0665 / B