Napoleon Fireplaces GD82NT-PA manual Horizontal Termination, Definitions, Elbow Vent Length Values

Page 7

DEFINITIONS

for the following symbols used in the venting calculations and examples are:

>- greater than

>- equal to or greater than < - less than

< - equal to or less than

HT - total of both horizontal vent lengths (HR) and offsets (HO) in feet

HR - combined horizontal vent lengths in feet

HO - offset factor: .03 (total degrees of offset - 90°*) in feet

VT - combined vertical vent lengths in feet

7

ELBOW VENT LENGTH VALUES

 

feet

inches

0.03

0.5

15°

0.45

6.0

30°

0.9

11.0

45°

1.35

16.0

90°*

2.7

32.0

*the fi rst 90° offset has a zero value and is shown in the formula as -90°

HORIZONTAL TERMINATION

when (HT) < (VT)

Simple venting confi guration (only one 90° elbow)

FIGURE 5

See graph to determine the required vertical rise VT for the required horizontal run HT.

For vent confi gurations requiring more than one 90° elbow, the following formulas apply:

Formula 1: HT < VT

Formula 2: HT + VT < 40 feet

90° H2

FIGURE 6

V2

 

90°

90°

H1

VERTICAL

RISE IN

FEET

VT

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

The shaded area within the lines represents acceptable values for HT and VT .

V1

Example 1:

V1 = 3 ft V2 = 8 ft

VT = V1 + V2 = 3 + 8 = 11 ft H1 = 2.5 ft

H2 = 2 ft

HR = H1 + H2 = 2.5 + 2 = 4.5 ft

HO = .03 (three 90° elbows - 90°) = .03(270° - 90°) = 5.4 ft HT = HR + HO = 4.5 + 5.4 = 9.9 ft

HT + VT = 9.9 + 11 = 20.9 ft

Formula 1: HT < VT 9.9 < 11

Formula 2: HT + VT < 40 feet 20.9 < 40

Since both formulas are met, this vent configuration is acceptable.

W415-0665 / B / 02.11.08

Image 7
Contents Installation Operation Instructions Table of Contents W415-0665 / B Installation Overview Fireplace DimensionsGeneral Instructions Supplier VentingDefinitions Horizontal TerminationElbow Vent Length Values = .03 four 90 elbows 90 = .03360 90 = 8.1 ft = .03 two 90 elbows 90 = .03180 90 =Vertical Termination Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Minimum AIR Terminal Location Clearances Installation Wall and Ceiling Protection Using Flexible Vent Components Using Rigid Vent Components Atención Minimum Enclosure Height Non-combustible fireplace finishing Minimum Enclosure ClearancesCombustible fireplace finishing Minimum Mantel and Enclosure Clearances Hard Wiring ConnectionElectrical Schematic Electrical ConnectionStep FinishingDoor Removal LOG Shipping BracketGlowing Embers LOG PlacementBlower Replacement GLASS/DOOR ReplacementBurner and Valve Replacement Bulb with bare fingers, protect With a clean dry clothOperation General Transmitter Layout Fireplace OperationFlame Height Temperature DisplayHand Held Remote Operations Smart ThermostatRemote Auxiliary Outlet LOW Battery / Manual BypassFAN Speed Child Proof FunctionTo Turn OFF GAS Operating InstructionsWhat to do if YOU Smell GAS Lighting InstructionsVenturi Adjustment AdjustmentsPilot Burner Adjustment Flame CharacteristicsReplacements W415-0665 / B Symptom Problem Test Solution Trouble Shooting GuideThemostat or switch is de Fireplace Service History W415-0665 / B