FireplaceXtrordinair 864 HH installation manual Remote Control Receiver Installation 2 Options

Page 56

56

Optional Equipment (for qualified installers only)

Remote Control Receiver Installation (2 Options)

The instructions below detail installation of the optional remote control receiver. For operating instructions, refer to the instructions included with the remote.

OPTION # 1 - Remote Thermostat (99300653)

Attach the power cord to the electrical receptacle on the inside of the fireplace.

WARNING: Make sure the power cord does not contact the blower (if applicable) or the bottom of firebox (or other hot surface).

Use lock-ties or wire ties to shorten the power cord to approximately 12” length.

Place the receiver in a location to the left of the gas control valve (near the front of the fireplae).

Attach the two reciever wires to the top and bottom posts on the gas control valve (orientation does not matter).

OPTION # 2 - Remote Thermostat (99300677)

Place the receiver in a location to the left of the gas control valve (near the front of the fireplae).

Remove and discard this molex connector attached to the blower wiring harness.

Connect the receiver to the molex connector on the wiring harness.

Travis Industries

4080214

100-01182_003

Image 56
Contents HH Fireplace Overview Listing DetailsIAS Icbo Approval Massachusetts ApprovalTable of Contents Safety Precautions Safety WarningsSafety Precautions Dimensions Installation OptionsHeating Specifications Installation Overview Recommended Installation ProcedurePacking List Additional Items RequiredMassachusetts Requirements Requirements for the Commonwealth of MassachusettsTop Vent or Rear Vent Configuration Converting Fireplace to Top Vent ConfigurationConverting the Fireplace to Top Vent Do not Over Tighten ScrewsRaised Fireplaces Fireplace Placement RequirementsClearances Minimum Framing Dimensions Rear Vent Configuration Minimum 49 Fireplace Enclosure HeightMinimum Framing Dimensions Top Vent Configuration TOP View Nailing BracketsCorner Installations Rear Vent Configuration Corner Installations Top Vent Configuration Gas Line Requirements FuelGas Line Connection Gas Inlet PressureGas Line Location Left Side Gas Inlet preferredElectrical Connection required Wall Switch Installation Wall Switch or Thermostat InstallationWiring Diagram Millivolt System Altitude Considerations Vent RequirementsVent Clearances Vent Installation Approved VentRestrictor Position Approved Vent ConfigurationsExhaust Restrictor Adjustment Intake Restrictor Adjustment Diffuser Plate Adjustment Diffuser Side ViewExhaust Restrictor Removal 0feet 5feet 22 max Feet 10feet 15feet Rear Vent Configuration with Vertical Termination Top Vent Configuration with Horizontal Termination Feet 21 max 5feet 10feet 15feetTop Vent Configuration with Vertical Termination Termination Requirements Hearth Requirements Floor Mounted FireplacesDrywall Installation Facing RequirementsOptional Faceplates Sizing Chart Facing OverviewFront View Raised Fireplace with no Hearth Front View Thick Facing with Fireplace Xtrordinair FPX Arched Faces Thick Facing Installation Side Floor-Mounted Fireplace with HearthMantel Requirements Side View Installation Example Build-In with Horizontal Termination Pilot Flame Inspection Steps for Finalizing the InstallationStarting the Pilot Flame Finalizing the Installation for qualified installers only Air Shutter AdjustmentGlass Frame Removal and Installation Re-Attaching the Glass FrameFinalizing the Installation for qualified installers only Fireback and Grate Installation Right Log Installation Log Set InstallationRear Log Installation Left Log Installation Right Twig Installation Verify Rear LOG PositionEmber Installation Center Twig InstallationFront Twigs Installation LP Conversion Instructions Follow the directions below to replace the orifices Slotted Screwdriver Or T-20 Torx Grill Installation Upper Grill InstallationOption # 2 Remote Thermostat Remote Control Receiver Installation 2 OptionsOption # 1 Remote Thermostat Special Instructions for 864 HH Extra Room Power Heat Duct skuNew Wire Hook-Up Length = Installation OverviewMaximum Duct Duct Installation Instructions LengthFloor Mounting Attach the grill and wall adapter, if necessary Wiring Diagram -864TRV Follow the directions below to wire the blower boxOperating Instructions OFFAccent Light Installation sku Optional Equipment for qualified installers only Optional Wall-Mounted Rheostat Accent Light OperationOptional Equipment for qualified installers only 68Index Index