62 | Optional Equipment (for qualified installers only) |
Wiring Instructions
Warning: All wiring should be done by a qualified electrician and shall be in compliance with local codes and with the current National Electric Code ANSI/NFPA 70.
Warning: Make sure the fireplace electrical circuit is disabled prior to working on electrical hookup.
Wiring Diagram - 864 HH*, 44 DV XXL, and 36 DV
Heat Duct
Rheostat
|
| Fireplace | Blower |
|
|
| Snap Disk |
Supply | Hot | Hot | Molex |
Common | Common | ||
| (black) | (black) |
|
Power | (white) | (white) | Connector |
Ground | Ground |
| |
(green) | (green) |
|
Molex
Connector
Hot | Hot |
(black) | (black) |
Common | Common |
(white) | (white) |
Ground | Ground |
(green) | (green) |
Hot
(black)
Rheostat
Junction
Box
Hot
(black)
Common
(white)
Ground (green)
| Heat Duct |
| Blower |
Hot |
|
(black) |
|
Common |
|
(white) |
|
Ground |
|
(green) |
|
Blower |
|
Junction |
|
Box | Grounded |
| to Blower |
Fireplace Fireplace
Blower Rheostat
Common
(white)
Ground (green)
Optional Second Heat
Duct (same rheostat and blower wiring as above)
Wiring Diagram -864TRV
*864 HH SN ?? or greater. 864 HH SN ?? or less uses wiring similar to the 864TRV.
Power Supply
| Rheostat |
| Junction Box |
Hot | Hot |
(black) | (black) |
Common | Common |
(white) | (white) |
Ground | Ground |
(green) | (green) |
Blower
Assembly
1Follow the directions below to wire the blower box.
a
Remove the cover from the blower box.
Phillips
Screwdriver
b
Standard
Screwdriver
Insert sheathed cable through the cable clamp. After the wires have been connected tighten the clamp to secure the cable.
c | Attach the hot (black) and common (white) wires to the |
leads coming from the wires (use wire nuts). |
Secure the ground wire to the ground stud inside the d blower box by tightening the included nut over the
ground wire.
Ground Wire