Heat & Glo LifeStyle 8000TRD manual Installers Guide, What to do if you smell gas

Page 1

Model:

Installers Guide

8000TRD

Underwriters

Laboratories Listed

WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUS- ING PROPERTY DAMAGE, PER- SONAL INJURY, OR DEATH.

- Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance.

-What to do if you smell gas

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

-Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

Printed in U.S.A. Copyright 2003,

Heat-N-Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044

READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE.

WARNING: IMPROPER INSTALLA- TION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAM- AGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFOR- MATION CONSULT A QUALIFIED IN- STALLER, SERVICE AGENCY, OR THE GAS SUPPLIER.

1.This appliance may be installed in an af- termarket, permanently located, manufac- tured (mobile) home, where not prohibited by local codes.

2.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

Please contact your Heat-N-Glo dealer for any questions or concerns. For the number of your nearest Heat-N- Glo dealer, please call 1-888-427-3973.

This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322; 4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia) 543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.

380-900J 3/03

1

Image 1 Contents
What to do if you smell gas Installers GuideSafety and Warning Information Table of Contents 8000TRD 18 9 Log Set AssemblyCommon Parts / Piéces Communes Service Parts List / Liste des pièces de rechange 8000TRDStanding Pilot Ignition / D’ALLUMAGE PAR Veilleuse IPI Ignition Allumage IPIHigh Altitude Installations Installation CodesAppliance Certification CertificationIntroducing the Heat-N-Glo Gas Fireplaces Pre-install PreparationANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the 8000TRD Locating the Fireplace Constructing the Fireplace ChaseClearance Requirements Space RequirementsFraming the Fireplace Framing Dimensions187mm 149mm 220mm DV-90D 164mm 216mm Vent System Approvals Installing the Vent SystemIdentifying Vent Components Terminations KitsVertical Venting Flue Restrictor InstructionsMAX .4 M Break HereChart Venting with One 90 Elbow Venting with ONE 1 90 ElbowVenting with TWO Elbows MIN MAX mm 610mm MAX .22m 914mm MAX .86m MAX .4m Venting with three 90 elbows Venting with Three 3 90 Elbows+ H 1 FT Stove Cement Must be Placed around Installing Vent Components5 Inch 127 MM Fireplace Starting COL Install Support Brackets To Install the Heat ShieldContinue Adding Vent Components 12 Hole and Vent Pipe Positioned SO That the Arrow is Pointing UP Vent Termination4 184mm Vent Termination Minimum Clearances Minimum Height from Roof to Lowest Discharge Opening Positioning, Leveling, and Securing the Fireplace Vice Must be Wired Directly to the FIRE- Place Junction BOXGas Control Systems Standing Pilot Ignition SystemGas Pressure Requirements Gas Supply LineCheck for GAS Leaks Natural Gas PropaneOptional Accessories Wiring the FireplaceOptional fan and remote control kits require that Position the wall switch in the desired position on a wallBlack Optional Battery BACK-UP RED Brown Operation using Battery PowerSealant Material Hearth Extensions FinishingInstalling the Trim Installing Trim, Logs, and Ember MaterialShutter Settings Burner Placing the Ember Material Outlet Grilles in ANY MannerGlass Specifications 8000TRD 26 1/2 X 42 1/2 Tempered After the InstallationDouble-check for faulty components Before Lighting the FireplaceCleaning Glass Door Fireplace MaintenanceImportant Turn OFF the GAS Before Servicing Your Fireplace Replacing old ember material
Related manuals
Manual 33 pages 3.26 Kb