Heat & Glo LifeStyle 8000TRD manual Venting with TWO Elbows

Page 16

VENTING WITH TWO (2)

90° ELBOWS

V

H

H + H1

1´ MIN. (305 mm)

2´ MAX. (610 mm)

5´ MAX. (1.52m)

2´ MIN. (610 mm)

4´ MAX. (1.22 m)

10´ MAX. (3.1m)

3´ MIN. (914 mm)

6´ MAX. (1.86 m)

15´ MAX. (4.65m)

4´ MIN. (1.22 m)

8´ MAX. (2.48 m)

20´ MAX. (6.2m)

V+H+H1 = 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m)

H+H1 = 20´ MAX. (6.2m)

Figure 13. Venting with Two 90° Elbows

VENTING WITH TWO (2) 90o ELBOWS

V FT.

 

H + H1 (FT.)

1' MIN.

(305mm)

5´ MAX. (1.52m)

2' MIN.

(610mm)

10´ MAX. (3.1m)

3' MIN.

(914mm)

15´ MAX. (4.65m)

4' MIN.

(1.22m)

20´ MAX. (6.2m)

V+H+H1= 40' MAX.(12.4m)

H+H1 = 20´ MAX. (6.2m)

V+V1+H = 40' MAX.(12.4m)

 

Figure 14. Venting with Two 90° Elbows

16

Image 16
Contents Installers Guide What to do if you smell gasSafety and Warning Information Table of Contents 18 9 Log Set Assembly 8000TRDService Parts List / Liste des pièces de rechange 8000TRD Common Parts / Piéces CommunesStanding Pilot Ignition / D’ALLUMAGE PAR Veilleuse IPI Ignition Allumage IPIInstallation Codes High Altitude InstallationsAppliance Certification CertificationIntroducing the Heat-N-Glo Gas Fireplaces Pre-install PreparationANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the 8000TRD Constructing the Fireplace Chase Locating the FireplaceClearance Requirements Space RequirementsFraming Dimensions Framing the Fireplace187mm 149mm 220mm DV-90D 164mm 216mm Installing the Vent System Vent System ApprovalsIdentifying Vent Components Terminations KitsFlue Restrictor Instructions Vertical VentingMAX .4 M Break HereChart Venting with ONE 1 90 Elbow Venting with One 90 ElbowVenting with TWO Elbows MIN MAX mm 610mm MAX .22m 914mm MAX .86m MAX .4m Venting with Three 3 90 Elbows Venting with three 90 elbows+ H 1 FT Stove Cement Must be Placed around Installing Vent Components5 Inch 127 MM Fireplace Starting COL Install Support Brackets To Install the Heat ShieldContinue Adding Vent Components 12 Hole and Vent Pipe Positioned SO That the Arrow is Pointing UP Vent Termination4 184mm Vent Termination Minimum Clearances Minimum Height from Roof to Lowest Discharge Opening Vice Must be Wired Directly to the FIRE- Place Junction BOX Positioning, Leveling, and Securing the FireplaceGas Control Systems Standing Pilot Ignition SystemGas Supply Line Gas Pressure RequirementsCheck for GAS Leaks Natural Gas PropaneWiring the Fireplace Optional AccessoriesOptional fan and remote control kits require that Position the wall switch in the desired position on a wallOperation using Battery Power Black Optional Battery BACK-UP RED BrownFinishing Sealant Material Hearth ExtensionsInstalling Trim, Logs, and Ember Material Installing the TrimShutter Settings Burner Placing the Ember Material Outlet Grilles in ANY MannerAfter the Installation Glass Specifications 8000TRD 26 1/2 X 42 1/2 TemperedDouble-check for faulty components Before Lighting the FireplaceFireplace Maintenance Cleaning Glass DoorImportant Turn OFF the GAS Before Servicing Your Fireplace Replacing old ember material