Desa (V)CD36TN, (V)CD36TP Vertical Termination Configurations for Top Vent, High Wind Termination

Page 19

Venting Installation

instructions

Continued

Vertical Termination Configurations for

Top Vent

Figures 30 and 33 show four different configura- tions for vertical termination.

VERTICAL VENT INSTALLATIONS USING MULTIPLE 90° ELBOWS (V)CD36T TOP VENT

Note: Install a

VR-58 vertical restrictor ring into inner pipe

section prior to

attaching vent

termination cap.

90° Elbow

Venting with Three 90° Elbows

 

Horizontal (H1) +

Vertical (V)

Horizontal (H2)

8' Min.

5' Max

10' Min.

8' Max

12' Min.

11' Max

14' Min.

14' Max

16' Min.

17' Max

18' Min.

20' Max

40' Min.

20' Max

Figure 30 - Vertical Venting

Configuration using Three 90° Elbows (Model (V)CD36T with Vertical Round High Wind Termination)

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H)

8' Min.

6' Max

9' Min.

8' Max

10' Min.

10' Max

12' Min.

14' Max

14' Min.

18' Max

40' Min.

20' Max

90° Elbow

Note: Install a

 

VR-58 vertical

 

restrictor ring

 

into inner pipe

 

section prior to

 

attaching vent

 

termination

 

cap.

Figure 31 - Vertical Venting Configuration Using Two 90° Elbows (Model (V)CD36T with Vertical Round

High Wind Termination)

 

Venting with Two 90°

 

Elbows

 

Vertical

Horizontal

 

(V1)

(H)

 

8' Min.

9' Max

 

9' Min.

11' Max

 

10' Min.

13' Max

 

12' Min.

17' Max

 

14' Min.

20' Max

 

Note: Install a

 

VR-58 vertical

 

restrictor ring

 

into inner pipe

 

section prior to

 

attaching vent

90° Elbow

termination

cap.

 

Note: Vertical (V1) + Vertical (V2) = 40' Max. Max. Horizontal Above 14' Vertical = 20'

Figure 32 - Vertical Venting

Configuration Using Two 90° Elbows (Model (V)CD36T with Vertical Round High Wind Termination)

116035-01E

www.desatech.com

19

Image 19
Contents VCD36TN, VCD36TNE Natural GAS ModelsVCD36RN, VCD36RNE PROPANE/LP GAS ModelS PROPANE/LP GAS ModelsTable of Contents Safety Information High traffic areas Product IdentificationLocation and space requirements Product FeaturesPre-Installation Preparation Local CodesClearances Packaging and RemovalMantel Clearances Framing and finishingSide Clearances for Combustible Materials Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsTwisting, bending, etc Installation PlanningLocation of the fireplace Feet. Use wall straps for this purposeInstalling Siding Standoff Combustible Exterior Wall Wall Firestop Installing Inner Wall FirestopHorizontal Termination Venting InstallationSnorkel 45 and 30 Offset with Wall Strap Installation for vertical terminationConnect a section of pipe and extend up through the hole Flat Ceiling InstallationTwist-lock the vent cap onto the last section of vent pipe Vertical Venting Vertical Termination Configurations for Rear VentHigh Wind Termination Vertical Termination Configurations for Top VentDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsElectrical Supply Connection Fireplace InstallationInstalling optional blower accessories Model BK InstallationBlower Model BK Plug in blower power cordPlug in blower power cord to duplex outlet Model BKT InstallationWiring Diagrams Locate the two plastic mounting clips provided with the kit Installing Remote ReceiverAttach the terminal wires to the battery. see Figure Installing and Activating the Remote ReceiverInstallation Items Needed High Altitude installationInstalling Gas Piping to Fireplace Location Important Fireplaces when factory equipped for use at highPropane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyClose equipment shutoff valve see Figure Pressure Testing Gas Supply Piping SystemChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPaRemoving Top Louver Trim Panel Pressure Testing Fireplace Gas ConnectionsRemoving Lower Louver Access Panel Removing/Replacing Glass DoorRemoving Glass Door Installing LOGS, lava rock and glowing embersOpen the bag of ember materials Millivolt For your safety Read before lightingOperating Fireplace Lighting InstructionsRemote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional Hand-HeldThermostat Series Model HRC200 Electronic ingnition For your safety Read before lighting Operating optional blower accessoryOperating optional GWMT1 Wall Mounted Thermostat Pilot Optional Wireless Remote OperationBurner Flame Pattern Pilot assemblyIf you pilot assembly does not meet these require- ments Inspecting BurnersGlass Door Cleaning MaintenancePilot and burners Venting system TroubleshootingObserved Problem Possible Cause Remedy LogsTurn on gas supply or open When ignitor button is pressedProblem could be caused by Burner orifice clogged Clean burner see Cleaning Is litOperation Processes and logs curing Hours of operation When burner is lit HI position when burner isOr shut off Service person Remote does not function Tery is power is lowStatement above Electronic Ignition Statement at top Gas leak. See WarningSpecifications Replacement PartsService Hints Technical ServiceThermostatically Controlled Blower KIT BKT AccessoriesPROPANE/NATURAL GAS Manual Blower KIT BKIllustrated Parts Breakdown Parts List Illustrated parts breakdown Washer, Flat 7/8 ID x 2 OD x 1/8 Thick Illustrated Parts Breakdown CD36TNEV Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.