Desa (V)CD36RNE, (V)CD36RPE, (V)CD36TP, (V)CD36TNE Plug in blower power cord, Blower Model BK

Page 22

Fireplace

Installation

Continued

2.Attach green ground wire from power cord to blower housing using screw provided (see Figure 35). Tighten screws securely.

3.Place blower against lower rear wall of the firebox outer wrapper with exhaust port di- rected upward. The blower will fit inside the back opening and be held in position against the back wall by magnets (see Figure 35).

4.Be certain that all wire terminals are securely at- tached to terminals on blower motor and that the screw retaining the green ground wire is tight.

5.Mount speed control box by placing plastic control shaft through opening in switch bracket (see Figure 36) or ignition module bracket (see Figure 37).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob provided on shaft.

7.Turn on power to duplex outlet if previously turned off per the warning in above.

8.Plug in blower power cord.

a.If your firebox is installed as a free- standing unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox.

b.If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox owner’s manual for instruc- tions on wiring the duplex outlet.

CAUTION: Never touch the blower wheel while in operation.

9.Check to make sure that the power cord is com- pletely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by turning knob fully counterclock- wise before continuing.

10.Peel off the backing paper and stick the sup- plied wiring diagram decal on the firebox bot- tom approximately 12" in front of the blower (see Figure 38, page 23).

Lower Firebox

Cavity

Side View

Blower Location

Spade

 

 

Magnetic

Terminals

 

Strips

Green

 

 

 

Ground

 

 

 

Wire

 

Screw Exhaust Port

 

 

Figure 35 - Blower Model BK

Switch

Speed Control Control Shaft

Bracket

 

 

 

Blower

 

 

 

Plug-In

 

 

 

Duplex Outlet

 

Locknut

(Located underneath

Control

firebox floor against

 

 

Knob

 

 

lower right outside wall)

Figure 36 - Attaching Speed Control to

Firebox (Millivolt Models)

Duplex Outlet

Speed

Control

Control

Ignition Locknut Knob

Control Module

Shaft Bracket

Figure 37 - Attaching Speed Control to

Firebox (Electronic Models)

22

www.desatech.com

116035-01E

Image 22
Contents PROPANE/LP GAS ModelS PROPANE/LP GAS Models Natural GAS ModelsVCD36RN, VCD36RNE VCD36TN, VCD36TNETable of Contents Safety Information Product Identification High traffic areasLocal Codes Product FeaturesPre-Installation Preparation Location and space requirementsPackaging and Removal ClearancesFraming and finishing Mantel ClearancesSide Clearances for Combustible Materials Location of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsFeet. Use wall straps for this purpose Installation PlanningLocation of the fireplace Twisting, bending, etcInstalling Siding Standoff Combustible Exterior Wall Installing Inner Wall Firestop Wall FirestopVenting Installation Horizontal TerminationSnorkel Installation for vertical termination 45 and 30 Offset with Wall StrapConnect a section of pipe and extend up through the hole Flat Ceiling InstallationTwist-lock the vent cap onto the last section of vent pipe Vertical Termination Configurations for Rear Vent Vertical VentingVertical Termination Configurations for Top Vent High Wind TerminationParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionModel BK Installation Fireplace InstallationInstalling optional blower accessories Electrical Supply ConnectionPlug in blower power cord Blower Model BKModel BKT Installation Plug in blower power cord to duplex outletWiring Diagrams Installing and Activating the Remote Receiver Installing Remote ReceiverAttach the terminal wires to the battery. see Figure Locate the two plastic mounting clips provided with the kitImportant Fireplaces when factory equipped for use at high High Altitude installationInstalling Gas Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Propane/LP Supply TankExternal Regulator Vent Pointing DownTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Gas Supply Piping SystemChecking GAS Connections Close equipment shutoff valve see FigureRemoving/Replacing Glass Door Pressure Testing Fireplace Gas ConnectionsRemoving Lower Louver Access Panel Removing Top Louver Trim PanelInstalling LOGS, lava rock and glowing embers Removing Glass DoorLighting Instructions Millivolt For your safety Read before lightingOperating Fireplace Open the bag of ember materialsOptional Hand-Held Manual Lighting ProcedureTo Turn OFF GAS To Appliance Remote OperationThermostat Series Model HRC200 Electronic ingnition For your safety Read before lighting Operating optional blower accessoryOperating optional GWMT1 Wall Mounted Thermostat Optional Wireless Remote Operation PilotInspecting Burners Pilot assemblyIf you pilot assembly does not meet these require- ments Burner Flame PatternGlass Door Cleaning MaintenancePilot and burners Logs TroubleshootingObserved Problem Possible Cause Remedy Venting systemBurner orifice clogged Clean burner see Cleaning Is lit When ignitor button is pressedProblem could be caused by Turn on gas supply or openTery is power is low When burner is lit HI position when burner isOr shut off Service person Remote does not function Operation Processes and logs curing Hours of operationStatement above Electronic Ignition Gas leak. See Warning Statement at topTechnical Service Replacement PartsService Hints SpecificationsManual Blower KIT BK AccessoriesPROPANE/NATURAL GAS Thermostatically Controlled Blower KIT BKTIllustrated Parts Breakdown Parts List Illustrated parts breakdown Washer, Flat 7/8 ID x 2 OD x 1/8 Thick Illustrated Parts Breakdown CD36TNEV Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.