Desa (V)CD36TNE, (V)CD36RPE High Altitude installation, Check Gas Type, Installation Items Needed

Page 26

Fireplace

Installation

Continued

4.Once the battery is activated the unit is ready to use.

5.Replace the bottom louver panel.

Battery

Back of

Cover

Handset

12 Volt

 

Battery

 

Back of

 

Handset

 

Figure 48 - Installing Battery Into

Handset WRC

High Altitude installation

Your DESA direct-vent fireplace has been tested and approved in the USA for elevations from 0-2000 feet (610 m) and in Canada at elevations from 0-4500 feet (1372 m).

High-altitude models as indicated by the letter suf- fix (-HA) are equipped with specific gas controls for installation above 4000 feet.

IMPORTANT: Fireplaces when factory equipped for use at high-

altitude can not be converted for use with Pro- pane/LP gas. When installing a non-high altitude fireplace at an elevation above 2000 feet (610 m) (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet (305 m) above sea level. Check with your local gas company for proper derate procedure and orifice size.

When installing this fireplace in Canada at an elevation above 4500 feet (1372 m), Check with local or provincial code authorities.

Consult your local gas company to help determine the proper orifice for your location.

For assistance with any high altitude installation contact DESA’s Customer Service Department at 1-866-672-6040.

Check Gas Type

Use proper gas type for the fireplace unit you are installing. If your gas supply is not correct, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type or to purchase gas conversion kit (see Accessories, page 45).

Installing Gas Piping to Fireplace Location

WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes.

CAUTION: For propane/LP units, never connect fireplace di- rectly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by local codes)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alterna- tive to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your retailer.

For propane/LP connection only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- sure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 49, page 27. Pointing the vent down protects it from freezing rain or sleet.

26

www.desatech.com

116035-01E

Image 26
Contents PROPANE/LP GAS ModelS PROPANE/LP GAS Models Natural GAS ModelsVCD36RN, VCD36RNE VCD36TN, VCD36TNETable of Contents Safety Information Product Identification High traffic areasLocal Codes Product FeaturesPre-Installation Preparation Location and space requirementsPackaging and Removal ClearancesFraming and finishing Mantel ClearancesSide Clearances for Combustible Materials Location of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsFeet. Use wall straps for this purpose Installation PlanningLocation of the fireplace Twisting, bending, etcInstalling Siding Standoff Combustible Exterior Wall Installing Inner Wall Firestop Wall FirestopVenting Installation Horizontal TerminationSnorkel Installation for vertical termination 45 and 30 Offset with Wall StrapTwist-lock the vent cap onto the last section of vent pipe Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Vertical Termination Configurations for Rear Vent Vertical VentingVertical Termination Configurations for Top Vent High Wind TerminationParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionModel BK Installation Fireplace InstallationInstalling optional blower accessories Electrical Supply ConnectionPlug in blower power cord Blower Model BKModel BKT Installation Plug in blower power cord to duplex outletWiring Diagrams Installing and Activating the Remote Receiver Installing Remote ReceiverAttach the terminal wires to the battery. see Figure Locate the two plastic mounting clips provided with the kitImportant Fireplaces when factory equipped for use at high High Altitude installationInstalling Gas Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Propane/LP Supply TankExternal Regulator Vent Pointing DownTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Gas Supply Piping SystemChecking GAS Connections Close equipment shutoff valve see FigureRemoving/Replacing Glass Door Pressure Testing Fireplace Gas ConnectionsRemoving Lower Louver Access Panel Removing Top Louver Trim PanelInstalling LOGS, lava rock and glowing embers Removing Glass DoorLighting Instructions Millivolt For your safety Read before lightingOperating Fireplace Open the bag of ember materialsOptional Hand-Held Manual Lighting ProcedureTo Turn OFF GAS To Appliance Remote OperationThermostat Series Model HRC200 Operating optional GWMT1 Wall Mounted Thermostat Operating optional blower accessoryElectronic ingnition For your safety Read before lighting Optional Wireless Remote Operation PilotInspecting Burners Pilot assemblyIf you pilot assembly does not meet these require- ments Burner Flame PatternPilot and burners Cleaning MaintenanceGlass Door Logs TroubleshootingObserved Problem Possible Cause Remedy Venting systemBurner orifice clogged Clean burner see Cleaning Is lit When ignitor button is pressedProblem could be caused by Turn on gas supply or openTery is power is low When burner is lit HI position when burner isOr shut off Service person Remote does not function Operation Processes and logs curing Hours of operationStatement above Electronic Ignition Gas leak. See Warning Statement at topTechnical Service Replacement PartsService Hints SpecificationsManual Blower KIT BK AccessoriesPROPANE/NATURAL GAS Thermostatically Controlled Blower KIT BKTIllustrated Parts Breakdown Parts List Illustrated parts breakdown Washer, Flat 7/8 ID x 2 OD x 1/8 Thick Illustrated Parts Breakdown CD36TNEV Limited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.