Desa (V)CD36TPE, (V)CD36RPE, (V)CD36TNE Inspecting Burners, Pilot assembly, Burner Flame Pattern

Page 36

OPERATIng fireplace

Continued

Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fire- place and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blow- er will continue to run. The blower will shut off after the firebox temperature decreases.

The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt or other obstructions that will hinder the flow of air.

If you pilot assembly does not meet these require- ments:

turn fireplace off (see To Turn Off Gas to Ap- pliance, page 32 or 35 depending on model)

see Troubleshooting, page 38

 

Sensor

Pilot

Rod

 

Burner

 

 

Piezo

 

Ignitor

 

OFF ON

 

 

 

N

 

 

 

O

L

 

 

 

 

 

T

O

I

ON OFF REMOTE

O

O

H

 

L

 

 

IP FF

 

Figure 65 - Setting the Selector Switch, Gas Control Knob and Variable Control Knob for Remote Operation

Inspecting Burners

Check pilot flame pattern and burner flame pat- terns often.

pilot assembly

The pilot assembly is factory preset for the proper flame height. Alterations may have occurred dur- ing shipping and handling. Call a qualified service person to readjust the pilot if necessary.

The position and pattern of the pilot flames in rela- tion to the sensing devices should be as shown in Figures 66 and 67 depending on model.

Thermopile

3/8" to 1/2"

Pilot Burner

1/8"

Thermocouple

Piezo

Ignitor

Figure 66 - Pilot Assembly (Millivolt)

Figure 67 - Pilot Assembly (Electronic)

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions.

If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be danger- ous. Inspect the flames after installation to ensure proper installation and performance.

Figure 68 shows a typical flame pattern.

If burner flame pattern differs from that de- scribed:

turn fireplace off (see To Turn Off Gas to Ap- pliance, page 32 or 35 depending on model)

see Troubleshooting, page 38

Figure 68 - Typical Flame Pattern

36

www.desatech.com

116035-01E

Image 36
Contents Natural GAS Models VCD36RN, VCD36RNEPROPANE/LP GAS ModelS PROPANE/LP GAS Models VCD36TN, VCD36TNETable of Contents Safety Information Product Identification High traffic areasProduct Features Pre-Installation PreparationLocal Codes Location and space requirementsPackaging and Removal ClearancesFraming and finishing Mantel ClearancesSide Clearances for Combustible Materials Location of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Location of the fireplaceFeet. Use wall straps for this purpose Twisting, bending, etcInstalling Siding Standoff Combustible Exterior Wall Installing Inner Wall Firestop Wall FirestopVenting Installation Horizontal TerminationSnorkel Installation for vertical termination 45 and 30 Offset with Wall StrapFlat Ceiling Installation Connect a section of pipe and extend up through the holeTwist-lock the vent cap onto the last section of vent pipe Vertical Termination Configurations for Rear Vent Vertical VentingVertical Termination Configurations for Top Vent High Wind TerminationParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionFireplace Installation Installing optional blower accessoriesModel BK Installation Electrical Supply ConnectionPlug in blower power cord Blower Model BKModel BKT Installation Plug in blower power cord to duplex outletWiring Diagrams Installing Remote Receiver Attach the terminal wires to the battery. see FigureInstalling and Activating the Remote Receiver Locate the two plastic mounting clips provided with the kitHigh Altitude installation Installing Gas Piping to Fireplace LocationImportant Fireplaces when factory equipped for use at high Installation Items NeededConnecting Fireplace to GAS Supply Propane/LP Supply TankExternal Regulator Vent Pointing DownPressure Testing Gas Supply Piping System Checking GAS ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Close equipment shutoff valve see FigurePressure Testing Fireplace Gas Connections Removing Lower Louver Access PanelRemoving/Replacing Glass Door Removing Top Louver Trim PanelInstalling LOGS, lava rock and glowing embers Removing Glass DoorMillivolt For your safety Read before lighting Operating FireplaceLighting Instructions Open the bag of ember materialsManual Lighting Procedure To Turn OFF GAS To ApplianceOptional Hand-Held Remote OperationThermostat Series Model HRC200 Operating optional blower accessory Electronic ingnition For your safety Read before lightingOperating optional GWMT1 Wall Mounted Thermostat Optional Wireless Remote Operation PilotPilot assembly If you pilot assembly does not meet these require- mentsInspecting Burners Burner Flame PatternCleaning Maintenance Glass DoorPilot and burners Troubleshooting Observed Problem Possible Cause RemedyLogs Venting systemWhen ignitor button is pressed Problem could be caused byBurner orifice clogged Clean burner see Cleaning Is lit Turn on gas supply or openWhen burner is lit HI position when burner is Or shut off Service person Remote does not functionTery is power is low Operation Processes and logs curing Hours of operationStatement above Electronic Ignition Gas leak. See Warning Statement at topReplacement Parts Service HintsTechnical Service SpecificationsAccessories PROPANE/NATURAL GASManual Blower KIT BK Thermostatically Controlled Blower KIT BKTIllustrated Parts Breakdown Parts List Illustrated parts breakdown Washer, Flat 7/8 ID x 2 OD x 1/8 Thick Illustrated Parts Breakdown CD36TNEV Warranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.