Desa (V)CD36TNE, (V)CD36RPE, (V)CD36TPE Operating optional GWMT1 Wall Mounted Thermostat

Page 34

Operating fireplace

Continued

operating optional

GWMT1 - Wall Mounted

Thermostat

WARNING: Do not con- nect the thermostat to a power source. Electrical shock and/or a fire hazard will occur.

Light the fireplace as instructed in Lighting Instructions on page 31. Set wall thermostat to desired temperature.

This thermostat has been electronically cali- brated at the factory and requires no adjust- ment or leveling.

Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation. To turn the fireplace off, adjust thermostat to the lowest setting and turn the gas control knob back to PILOT. The pilot will remain lit.

IMPORTANT: To turn the pilot off, turn the gas control knob on the heater to the OFF position.

operating optional blower accessory

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the right side of the switch bracket to the left just inside the louver panel. The BK manual blower and the BKT thermo- statically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fire- place and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blow- er will continue to run. The blower will shut off after the firebox temperature decreases.

The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt or other obstructions that will hinder the flow of air.

Electronic ingnition

for your safety

Read before lighting

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

C.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

lighting

instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.Turn wall switch to the OFF position.

4.Open lower louver panel.

5.Turn equipment shutoff valve clockwise to the OFF position (see Figure 63). Do not force.

Equipment

Adjustment

Shutoff Valve

Screw

Figure 63 - Turning Equipment Shutoff Valve

to the OFF Position

34

www.desatech.com

116035-01E

Image 34
Contents PROPANE/LP GAS ModelS PROPANE/LP GAS Models Natural GAS ModelsVCD36RN, VCD36RNE VCD36TN, VCD36TNETable of Contents Safety Information Product Identification High traffic areasLocal Codes Product FeaturesPre-Installation Preparation Location and space requirementsPackaging and Removal ClearancesFraming and finishing Mantel ClearancesSide Clearances for Combustible Materials Location of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsFeet. Use wall straps for this purpose Installation PlanningLocation of the fireplace Twisting, bending, etcInstalling Siding Standoff Combustible Exterior Wall Installing Inner Wall Firestop Wall FirestopVenting Installation Horizontal TerminationSnorkel Installation for vertical termination 45 and 30 Offset with Wall StrapConnect a section of pipe and extend up through the hole Flat Ceiling InstallationTwist-lock the vent cap onto the last section of vent pipe Vertical Termination Configurations for Rear Vent Vertical VentingVertical Termination Configurations for Top Vent High Wind TerminationParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionModel BK Installation Fireplace InstallationInstalling optional blower accessories Electrical Supply ConnectionPlug in blower power cord Blower Model BKModel BKT Installation Plug in blower power cord to duplex outletWiring Diagrams Installing and Activating the Remote Receiver Installing Remote ReceiverAttach the terminal wires to the battery. see Figure Locate the two plastic mounting clips provided with the kitImportant Fireplaces when factory equipped for use at high High Altitude installationInstalling Gas Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Propane/LP Supply TankExternal Regulator Vent Pointing DownTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Gas Supply Piping SystemChecking GAS Connections Close equipment shutoff valve see FigureRemoving/Replacing Glass Door Pressure Testing Fireplace Gas ConnectionsRemoving Lower Louver Access Panel Removing Top Louver Trim PanelInstalling LOGS, lava rock and glowing embers Removing Glass DoorLighting Instructions Millivolt For your safety Read before lightingOperating Fireplace Open the bag of ember materialsOptional Hand-Held Manual Lighting ProcedureTo Turn OFF GAS To Appliance Remote OperationThermostat Series Model HRC200 Electronic ingnition For your safety Read before lighting Operating optional blower accessoryOperating optional GWMT1 Wall Mounted Thermostat Optional Wireless Remote Operation PilotInspecting Burners Pilot assemblyIf you pilot assembly does not meet these require- ments Burner Flame PatternGlass Door Cleaning MaintenancePilot and burners Logs TroubleshootingObserved Problem Possible Cause Remedy Venting systemBurner orifice clogged Clean burner see Cleaning Is lit When ignitor button is pressedProblem could be caused by Turn on gas supply or openTery is power is low When burner is lit HI position when burner isOr shut off Service person Remote does not function Operation Processes and logs curing Hours of operationStatement above Electronic Ignition Gas leak. See Warning Statement at topTechnical Service Replacement PartsService Hints SpecificationsManual Blower KIT BK AccessoriesPROPANE/NATURAL GAS Thermostatically Controlled Blower KIT BKTIllustrated Parts Breakdown Parts List Illustrated parts breakdown Washer, Flat 7/8 ID x 2 OD x 1/8 Thick Illustrated Parts Breakdown CD36TNEV Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.