Desa (V)CD36RPE, (V)CD36TP, (V)CD36TNE Cleaning Maintenance, Glass Door, Pilot and burners

Page 37

Cleaning and

Maintenance

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep control areas, burners and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

GLASS DOOR

WARNING: Handle glass door panel with care. Do not strike, slam or otherwise abuse glass. Do not operate fireplace with the glass door unlatched, removed, cracked or broken.

WARNING: Do not use abra- sivecleanersasthismaydamage glass. Use a nonabrasive house- hold glass cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, nonabrasive household cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Remov- ing/Replacing Glass Door, page 29 of this manual when removing glass door for cleaning.

WARNING: Only parts sup- pliedbythemanufacturershould be used when replacing broken or damaged glass door panel (see Replacement Parts, page 44). This glass door panel is a complete unit. No substitute materials may be used.

CAUTION: Wear gloves and safety glasses while handling or removingbrokenglass.Donotre- moveifglassishot.Keepchildren and pets away from glass.

If glass has been broken, carefully remove glass door (see Removing/Replacing Glass Door, page 29). Vacuum all glass pieces with a shop vac.

CAUTION: Do not vacuum if pieces are hot.

Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page 44 for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 29 for instructions for replacing glass door.

WARNING: Do not operate fireplace with the glass door unlatched, removed, cracked or broken.

pilot and burners

Remove ember material before cleaning burners and replace when cleaning is complete.

Burner and controls should be cleaned with compressed air to remove dust, dirt or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt or lint.

116035-01E

www.desatech.com

37

Image 37
Contents VCD36RN, VCD36RNE Natural GAS ModelsPROPANE/LP GAS ModelS PROPANE/LP GAS Models VCD36TN, VCD36TNETable of Contents Safety Information High traffic areas Product IdentificationPre-Installation Preparation Product FeaturesLocal Codes Location and space requirementsClearances Packaging and RemovalMantel Clearances Framing and finishingSide Clearances for Combustible Materials Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsLocation of the fireplace Installation PlanningFeet. Use wall straps for this purpose Twisting, bending, etcInstalling Siding Standoff Combustible Exterior Wall Wall Firestop Installing Inner Wall FirestopHorizontal Termination Venting InstallationSnorkel 45 and 30 Offset with Wall Strap Installation for vertical terminationConnect a section of pipe and extend up through the hole Flat Ceiling InstallationTwist-lock the vent cap onto the last section of vent pipe Vertical Venting Vertical Termination Configurations for Rear VentHigh Wind Termination Vertical Termination Configurations for Top VentDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsInstalling optional blower accessories Fireplace InstallationModel BK Installation Electrical Supply ConnectionBlower Model BK Plug in blower power cordPlug in blower power cord to duplex outlet Model BKT InstallationWiring Diagrams Attach the terminal wires to the battery. see Figure Installing Remote ReceiverInstalling and Activating the Remote Receiver Locate the two plastic mounting clips provided with the kitInstalling Gas Piping to Fireplace Location High Altitude installationImportant Fireplaces when factory equipped for use at high Installation Items NeededPropane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemTest Pressures Equal To or Less Than Psig 3.5 kPa Close equipment shutoff valve see FigureRemoving Lower Louver Access Panel Pressure Testing Fireplace Gas ConnectionsRemoving/Replacing Glass Door Removing Top Louver Trim PanelRemoving Glass Door Installing LOGS, lava rock and glowing embersOperating Fireplace Millivolt For your safety Read before lightingLighting Instructions Open the bag of ember materialsTo Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held Remote OperationThermostat Series Model HRC200 Electronic ingnition For your safety Read before lighting Operating optional blower accessoryOperating optional GWMT1 Wall Mounted Thermostat Pilot Optional Wireless Remote OperationIf you pilot assembly does not meet these require- ments Pilot assemblyInspecting Burners Burner Flame PatternGlass Door Cleaning MaintenancePilot and burners Observed Problem Possible Cause Remedy TroubleshootingLogs Venting systemProblem could be caused by When ignitor button is pressedBurner orifice clogged Clean burner see Cleaning Is lit Turn on gas supply or openOr shut off Service person Remote does not function When burner is lit HI position when burner isTery is power is low Operation Processes and logs curing Hours of operationStatement above Electronic Ignition Statement at top Gas leak. See WarningService Hints Replacement PartsTechnical Service SpecificationsPROPANE/NATURAL GAS AccessoriesManual Blower KIT BK Thermostatically Controlled Blower KIT BKTIllustrated Parts Breakdown Parts List Illustrated parts breakdown Washer, Flat 7/8 ID x 2 OD x 1/8 Thick Illustrated Parts Breakdown CD36TNEV Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.