Desa (V)CD36RPE, (V)CD36TNE, (V)CD36TPE, (V)CD36RNE Washer, Flat 7/8 ID x 2 OD x 1/8 Thick

Page 49

PARTS LIST

BURNER ASSEMBLY FOR MODELS (V)CD36RN, (V)CD36RP, (V)CD36TN, (V)CD36TP (V)CD36RN-HA, (V)CD36TN-HA

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 44 of this manual.

KEY

NO. PART NO. DESCRIPTION

1 116317-01 Remote Ignitor Bracket

2 114886-01 Door Retainer Bracket

3 108085-01 Pilot Orifice #51

108085-02 Pilot Orifice #30

108085-03 Pilot Orifice #62

4 108084-02 Pilot Assembly

 

108084-05

Pilot Assembly

 

108084-03

Pilot Assembly

5

27206

Burner Orifice #44

 

26482

Burner Orifice #55

6

26808

Valve Bracket

7

24389

Tube 3/8" Dia. x 11" Aluminum

8

24360

Pilot Bracket

9

14500

Fitting 3/8" MPT x 1/2” Flare

1014399 Fitting Brass Elbow 3/8" MPT x 3/8" Comp. Tube

1114396 Fitting Brass Straight 3/8" MPT x 3/8” Comp. Tube

12

14389

Gas Control Valve Millivolt

 

117370-01 Gas Control Valve Millivolt

 

14390

Gas Control Valve Millivolt

13

14299

Air Shutter

14

14261

Ignitor Piezo

15

11226

Washer, Flat 7/8" ID x 2" OD x 1/8" Thick

16

11214

Fitting Bulkead w/ Nut Brass

17

11187

Screw, #8 x 1/4" PPH

18

11107

Screw, #10-32 x 1/4" PPH Zinc

19

11105

Screw, #10 x 1/2" HWH LGM Zinc

20

11102

Screw, #8 x 3/8" PPH F Zinc.

V (

 

HA

 

 

HA

 

)CD36RN )VCD36RN

-

 

 

-

 

)CD36RPV

)VCD36TN

)VCD36TN

V

)CD36TP

(

(

(

(

(

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QTY.

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

1

1

4

10

2

116035-01E

www.desatech.com

49

Image 49
Contents VCD36RN, VCD36RNE Natural GAS ModelsPROPANE/LP GAS ModelS PROPANE/LP GAS Models VCD36TN, VCD36TNETable of Contents Safety Information High traffic areas Product IdentificationPre-Installation Preparation Product FeaturesLocal Codes Location and space requirementsClearances Packaging and RemovalMantel Clearances Framing and finishingSide Clearances for Combustible Materials Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsLocation of the fireplace Installation PlanningFeet. Use wall straps for this purpose Twisting, bending, etcInstalling Siding Standoff Combustible Exterior Wall Wall Firestop Installing Inner Wall FirestopHorizontal Termination Venting InstallationSnorkel 45 and 30 Offset with Wall Strap Installation for vertical terminationConnect a section of pipe and extend up through the hole Flat Ceiling InstallationTwist-lock the vent cap onto the last section of vent pipe Vertical Venting Vertical Termination Configurations for Rear VentHigh Wind Termination Vertical Termination Configurations for Top VentDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsInstalling optional blower accessories Fireplace InstallationModel BK Installation Electrical Supply ConnectionBlower Model BK Plug in blower power cordPlug in blower power cord to duplex outlet Model BKT InstallationWiring Diagrams Attach the terminal wires to the battery. see Figure Installing Remote ReceiverInstalling and Activating the Remote Receiver Locate the two plastic mounting clips provided with the kitInstalling Gas Piping to Fireplace Location High Altitude installationImportant Fireplaces when factory equipped for use at high Installation Items NeededPropane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemTest Pressures Equal To or Less Than Psig 3.5 kPa Close equipment shutoff valve see FigureRemoving Lower Louver Access Panel Pressure Testing Fireplace Gas ConnectionsRemoving/Replacing Glass Door Removing Top Louver Trim PanelRemoving Glass Door Installing LOGS, lava rock and glowing embersOperating Fireplace Millivolt For your safety Read before lightingLighting Instructions Open the bag of ember materialsTo Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held Remote OperationThermostat Series Model HRC200 Electronic ingnition For your safety Read before lighting Operating optional blower accessoryOperating optional GWMT1 Wall Mounted Thermostat Pilot Optional Wireless Remote OperationIf you pilot assembly does not meet these require- ments Pilot assemblyInspecting Burners Burner Flame PatternGlass Door Cleaning MaintenancePilot and burners Observed Problem Possible Cause Remedy TroubleshootingLogs Venting systemProblem could be caused by When ignitor button is pressedBurner orifice clogged Clean burner see Cleaning Is lit Turn on gas supply or openOr shut off Service person Remote does not function When burner is lit HI position when burner isTery is power is low Operation Processes and logs curing Hours of operationStatement above Electronic Ignition Statement at top Gas leak. See WarningService Hints Replacement PartsTechnical Service SpecificationsPROPANE/NATURAL GAS AccessoriesManual Blower KIT BK Thermostatically Controlled Blower KIT BKTIllustrated Parts Breakdown Parts List Illustrated parts breakdown Washer, Flat 7/8 ID x 2 OD x 1/8 Thick Illustrated Parts Breakdown CD36TNEV Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.