Desa (V)CD36RPE, (V)CD36TNE, (V)CD36TPE, (V)CD36RNE installation manual Safety Information

Page 3

Safety Information

WARNING: This product con- tainsand/orgenerateschemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

IMPORTANT: Read this owner’s manual carefully and completely beforetryingtoassemble,operate or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

This fireplace must be installed by a qualified (cer- tified or licensed) service person. It has a sealed gas combustion chamber that uses a coaxial pipe (pipe within a pipe and having the same center) venting system. It brings in fresh air for combus- tion through the outer pipe and combustion gases are exhausted through the inner pipe. If the glass door assembly and venting pipe are not properly seated, connected and sealed, carbon monoxide leakage (spillage) can occur.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.

Propane/LP & Natural Gas: Propane/LP and natural gas are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this fireplace or it’s controls can be dangerous. Do not modify this fireplace under any circum- stances. Any parts removed for servicing must be replaced prior to operating fireplace.

WARNING: Do not use a blow- erinsert,heatexchangerinsertor other accessory not approved for use with this fireplace.

WARNING: This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the appliance.

Do not use this fireplace to cook food or burn paper or other flam- mable material.

This fireplace reaches high tem- peratures. Keep children and adults away from hot surface to avoid burns or clothing ignition. Fireplacewillremainhotforatime after shutdown. Allow surface to cool before touching.

116035-01Ewww.desatech.com

Image 3
Contents VCD36TN, VCD36TNE Natural GAS ModelsVCD36RN, VCD36RNE PROPANE/LP GAS ModelS PROPANE/LP GAS ModelsTable of Contents Safety Information High traffic areas Product IdentificationLocation and space requirements Product FeaturesPre-Installation Preparation Local CodesClearances Packaging and RemovalMantel Clearances Framing and finishingSide Clearances for Combustible Materials Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsTwisting, bending, etc Installation PlanningLocation of the fireplace Feet. Use wall straps for this purposeInstalling Siding Standoff Combustible Exterior Wall Wall Firestop Installing Inner Wall FirestopHorizontal Termination Venting InstallationSnorkel 45 and 30 Offset with Wall Strap Installation for vertical terminationFlat Ceiling Installation Connect a section of pipe and extend up through the holeTwist-lock the vent cap onto the last section of vent pipe Vertical Venting Vertical Termination Configurations for Rear VentHigh Wind Termination Vertical Termination Configurations for Top VentDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsElectrical Supply Connection Fireplace InstallationInstalling optional blower accessories Model BK InstallationBlower Model BK Plug in blower power cordPlug in blower power cord to duplex outlet Model BKT InstallationWiring Diagrams Locate the two plastic mounting clips provided with the kit Installing Remote ReceiverAttach the terminal wires to the battery. see Figure Installing and Activating the Remote ReceiverInstallation Items Needed High Altitude installationInstalling Gas Piping to Fireplace Location Important Fireplaces when factory equipped for use at highPropane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyClose equipment shutoff valve see Figure Pressure Testing Gas Supply Piping SystemChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPaRemoving Top Louver Trim Panel Pressure Testing Fireplace Gas ConnectionsRemoving Lower Louver Access Panel Removing/Replacing Glass DoorRemoving Glass Door Installing LOGS, lava rock and glowing embersOpen the bag of ember materials Millivolt For your safety Read before lightingOperating Fireplace Lighting InstructionsRemote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional Hand-HeldThermostat Series Model HRC200 Operating optional blower accessory Electronic ingnition For your safety Read before lightingOperating optional GWMT1 Wall Mounted Thermostat Pilot Optional Wireless Remote OperationBurner Flame Pattern Pilot assemblyIf you pilot assembly does not meet these require- ments Inspecting BurnersCleaning Maintenance Glass DoorPilot and burners Venting system TroubleshootingObserved Problem Possible Cause Remedy LogsTurn on gas supply or open When ignitor button is pressedProblem could be caused by Burner orifice clogged Clean burner see Cleaning Is litOperation Processes and logs curing Hours of operation When burner is lit HI position when burner isOr shut off Service person Remote does not function Tery is power is lowStatement above Electronic Ignition Statement at top Gas leak. See WarningSpecifications Replacement PartsService Hints Technical ServiceThermostatically Controlled Blower KIT BKT AccessoriesPROPANE/NATURAL GAS Manual Blower KIT BKIllustrated Parts Breakdown Parts List Illustrated parts breakdown Washer, Flat 7/8 ID x 2 OD x 1/8 Thick Illustrated Parts Breakdown CD36TNEV Warranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.