Desa V)CD36RN, (V)CD36RPE, (V)CD36TP, (V)CD36TNE Framing and finishing, Mantel Clearances

Page 7

Pre-Installation

Preparation

Continued

framing and finishing

Figure 5 shows typical framing of this fireplace. Figure 6 shows framing for corner installation. All minimum clearances must be met.

For overall unit dimensions, framing allowances and vent collar locations, see Unit Dimensions, Figure 9, page 8.

For available accessories for this fireplace, see Accessories on page 45. If you are using a separate combustible mantel piece, refer to Figure 7 and Figure 8, page 8 for proper height and clearances. You can install noncombustible mantels at any height above the fireplace.

Note: Noncombustible mantels may discolor!

24" Vertical

Double Stud

36"

 

(914 mm)

 

36 1/4"

 

(921 mm)

14 3/4"

 

 

(375 mm)

Figure 5 - Framing Clearances for Installation Against an Exterior Wall

MANTEL CLEARANCES

Figure 7 shows projected mantel depths at various heights above the top of the louver opening. Figure 8, page 8, shows the minimum allowable distances from various mantel components in relation to the both sides of the fireplace opening.

WARNING: When finishing appliance, do not overlap com- bustible materials onto the black frontface.Brick,tile,orothernon- combustible materials may be applied to the face provided that any fireplace openings are not blocked and gaps in the material used and the face are sealed with a non-combustible caulking.

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

3

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D E

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

6 5/8" ( 168 mm)

TO CENTER

OF REAR VENT

21" (533 mm)

TO CENTER OF

TOP VENT

285/8"

(727 mm)

2 1/2" (63 mm)

THESE DIMENSIONS ALLOW

MIN. 1" (26 mm)

FOR 1" OF CLEARANCE

 

AT THE SIDES AND BACK

14 3/4"

OF THE FIREPLACE

HOWEVER, 0" CLEARANCE

(375 mm)

IS ALSO PERMITTED AT

 

ALL SIDES WHEN FRAMED

14 3/4"

(375 mm)

TO NAILING

FLANGES

121/4"

 

 

(311 mm)

 

 

TO

56

3/4"

OPENING

 

(1441 mm)

 

 

 

Mantel from

 

 

 

Top of Louver

Ref.

Mantel Depth

Ref.

Opening

 

 

 

 

1

16" (406 mm)

A

14" (356 mm)

 

 

 

 

2

14" (356 mm)

A

12" (305 mm)

 

 

 

 

3

12" (305 mm)

B

10" (254 mm)

 

 

 

 

4

10" (254 mm)

C

8" (203 mm)

 

 

 

 

5

8" (203 mm)

D

6" (152 mm)

 

 

 

 

6

4" (101 mm)

F

4" (101 mm)

Figure 6 - Framing Clearances for Corner

Installation

7

2" (51 mm)

G 2" (51 mm)

Figure 7 - Clearances for Combustible

Mantels

116035-01Ewww.desatech.com

Image 7
Contents VCD36TN, VCD36TNE Natural GAS ModelsVCD36RN, VCD36RNE PROPANE/LP GAS ModelS PROPANE/LP GAS ModelsTable of Contents Safety Information High traffic areas Product IdentificationLocation and space requirements Product FeaturesPre-Installation Preparation Local CodesClearances Packaging and RemovalMantel Clearances Framing and finishingSide Clearances for Combustible Materials Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsTwisting, bending, etc Installation PlanningLocation of the fireplace Feet. Use wall straps for this purposeInstalling Siding Standoff Combustible Exterior Wall Wall Firestop Installing Inner Wall FirestopHorizontal Termination Venting InstallationSnorkel 45 and 30 Offset with Wall Strap Installation for vertical terminationConnect a section of pipe and extend up through the hole Flat Ceiling InstallationTwist-lock the vent cap onto the last section of vent pipe Vertical Venting Vertical Termination Configurations for Rear VentHigh Wind Termination Vertical Termination Configurations for Top VentDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsElectrical Supply Connection Fireplace InstallationInstalling optional blower accessories Model BK InstallationBlower Model BK Plug in blower power cordPlug in blower power cord to duplex outlet Model BKT InstallationWiring Diagrams Locate the two plastic mounting clips provided with the kit Installing Remote ReceiverAttach the terminal wires to the battery. see Figure Installing and Activating the Remote ReceiverInstallation Items Needed High Altitude installationInstalling Gas Piping to Fireplace Location Important Fireplaces when factory equipped for use at highPropane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyClose equipment shutoff valve see Figure Pressure Testing Gas Supply Piping SystemChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPaRemoving Top Louver Trim Panel Pressure Testing Fireplace Gas ConnectionsRemoving Lower Louver Access Panel Removing/Replacing Glass DoorRemoving Glass Door Installing LOGS, lava rock and glowing embersOpen the bag of ember materials Millivolt For your safety Read before lightingOperating Fireplace Lighting InstructionsRemote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional Hand-HeldThermostat Series Model HRC200 Electronic ingnition For your safety Read before lighting Operating optional blower accessoryOperating optional GWMT1 Wall Mounted Thermostat Pilot Optional Wireless Remote OperationBurner Flame Pattern Pilot assemblyIf you pilot assembly does not meet these require- ments Inspecting BurnersGlass Door Cleaning MaintenancePilot and burners Venting system TroubleshootingObserved Problem Possible Cause Remedy LogsTurn on gas supply or open When ignitor button is pressedProblem could be caused by Burner orifice clogged Clean burner see Cleaning Is litOperation Processes and logs curing Hours of operation When burner is lit HI position when burner isOr shut off Service person Remote does not function Tery is power is lowStatement above Electronic Ignition Statement at top Gas leak. See WarningSpecifications Replacement PartsService Hints Technical ServiceThermostatically Controlled Blower KIT BKT AccessoriesPROPANE/NATURAL GAS Manual Blower KIT BKIllustrated Parts Breakdown Parts List Illustrated parts breakdown Washer, Flat 7/8 ID x 2 OD x 1/8 Thick Illustrated Parts Breakdown CD36TNEV Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.