Desa (V)CD36TPE, (V)CD36RPE, (V)CD36TNE, (V)CD36RNE Parts list for venting kits and components

Page 20

Venting Installation

instructions

Continued

Note: Install a VR-58 vertical restrictor ring into inner pipe section prior to attaching vent termination cap.

WS-5 8

Note: Install an OSR58-30 30° offset return with WS-58 wall strap supports as necessary to maintain 1" Clearance to all horizontal wood frame members.

Vertical Venting

V = 40' Max.

Figure 33 - Vertical Venting

Configuration with No Horizontal Run (Model (V)CD36T with Vertical Round High Wind Termination)

parts list for venting kits and components

DESA (5"/8") Pipe & Vent Kits

Number Description

P58-6 6" Section Double Wall Pipe,

Galv.

P58-12 12" Section Double Wall Pipe,

Galv.

P58-24 24" Section Double Wall Pipe, Galv.

P58-36 36" Section Double Wall Pipe, Galv.

P58-48 48" Section Double Wall Pipe,

Galv.

PA58-712 Adjustable 7"-12" Section Double

Wall Pipe, Galv.

E58-45 45° Elbow, Galv.

E58-90 90° Elbow, Galv.

Number Description

VKG-58 Ground Floor Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12" Adjustable Pipe, Wall Firestop, Horizontal Square Termination, 16 Screws)

VKB-58 Basement Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12" Adjustable Pipe, Wall Firestop, Horizontal Square Termination, 4' Pipe, 90° Elbow, 20 Screws)

VKS-58 Snorkel Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12" Adjustable Pipe, Wall Firestop, 36" Snorkel Termination, 4' Pipe, 1' Pipe, 90° Elbow, 26 Screws)

VKR-58 Roof Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12" Adjustable Pipe, Flue Restrictor, Vertical High Wind Termination, 2' Pipe, 4' Pipe, Wall Firestop, Storm Collar, Roof Flashing [0/12 - 6/12], 26 Screws)

VKC-58 Corner Vent Kit, Galvanized (Includes 45° Elbow, 7"-12" Adjustable Pipe, Wall Firestop, Horizontal Termination, 6" Pipe, 90° Elbow, 18 Screws)

HHTK-58 High Wind Round Horizontal Termination Kit (Includes Round Termination, Wall Firestop, 45° Elbow)

HHT-58 High Wind Round Horizontal Termination Kit, Galv.

HTS-58 HorizontalSquareTermination,Galv. HTKS-58 Horizontal Square Termination Kit (Includes: Square Termination,

Wall Firestop, 45° Elbow)

VT-58 Vertical Round Termination, Galv. ST-58-14 14" Snorkel Termination, Galv. ST-58-36 36" Snorkel Termination, Galv. SC-58 Storm Collar, Galv.

WF-58 Wall Firestop, Galv.

RF-58-6 Roof Flashing - 0 to 6/12 Pitch, Galv.

RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch, Galv.

VR-58 Vertical Restrictor, Galv.

S-58 Vinyl Siding Standoff, Galv. WS-58 Wall Strap

CS-58 Cathedral Ceiling Support FP-58 Firestop Plate

SF-58 Stucco Flashing - For use with HTS-58

RF-58 Flat Roof Flashing

OSR58-30 30° Offset Return

20

www.desatech.com

116035-01E

Image 20
Contents Natural GAS Models VCD36RN, VCD36RNEPROPANE/LP GAS ModelS PROPANE/LP GAS Models VCD36TN, VCD36TNETable of Contents Safety Information Product Identification High traffic areasProduct Features Pre-Installation PreparationLocal Codes Location and space requirementsPackaging and Removal ClearancesFraming and finishing Mantel ClearancesSide Clearances for Combustible Materials Location of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Location of the fireplaceFeet. Use wall straps for this purpose Twisting, bending, etcInstalling Siding Standoff Combustible Exterior Wall Installing Inner Wall Firestop Wall FirestopVenting Installation Horizontal TerminationSnorkel Installation for vertical termination 45 and 30 Offset with Wall StrapTwist-lock the vent cap onto the last section of vent pipe Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Vertical Termination Configurations for Rear Vent Vertical VentingVertical Termination Configurations for Top Vent High Wind TerminationParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionFireplace Installation Installing optional blower accessoriesModel BK Installation Electrical Supply ConnectionPlug in blower power cord Blower Model BKModel BKT Installation Plug in blower power cord to duplex outletWiring Diagrams Installing Remote Receiver Attach the terminal wires to the battery. see FigureInstalling and Activating the Remote Receiver Locate the two plastic mounting clips provided with the kitHigh Altitude installation Installing Gas Piping to Fireplace LocationImportant Fireplaces when factory equipped for use at high Installation Items NeededConnecting Fireplace to GAS Supply Propane/LP Supply TankExternal Regulator Vent Pointing DownPressure Testing Gas Supply Piping System Checking GAS ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Close equipment shutoff valve see FigurePressure Testing Fireplace Gas Connections Removing Lower Louver Access PanelRemoving/Replacing Glass Door Removing Top Louver Trim PanelInstalling LOGS, lava rock and glowing embers Removing Glass DoorMillivolt For your safety Read before lighting Operating FireplaceLighting Instructions Open the bag of ember materialsManual Lighting Procedure To Turn OFF GAS To ApplianceOptional Hand-Held Remote OperationThermostat Series Model HRC200 Operating optional GWMT1 Wall Mounted Thermostat Operating optional blower accessoryElectronic ingnition For your safety Read before lighting Optional Wireless Remote Operation PilotPilot assembly If you pilot assembly does not meet these require- mentsInspecting Burners Burner Flame PatternPilot and burners Cleaning MaintenanceGlass Door Troubleshooting Observed Problem Possible Cause RemedyLogs Venting systemWhen ignitor button is pressed Problem could be caused byBurner orifice clogged Clean burner see Cleaning Is lit Turn on gas supply or openWhen burner is lit HI position when burner is Or shut off Service person Remote does not functionTery is power is low Operation Processes and logs curing Hours of operationStatement above Electronic Ignition Gas leak. See Warning Statement at topReplacement Parts Service HintsTechnical Service SpecificationsAccessories PROPANE/NATURAL GASManual Blower KIT BK Thermostatically Controlled Blower KIT BKTIllustrated Parts Breakdown Parts List Illustrated parts breakdown Washer, Flat 7/8 ID x 2 OD x 1/8 Thick Illustrated Parts Breakdown CD36TNEV Limited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.