Desa (V)CD36TP Installing Remote Receiver, Attach the terminal wires to the battery. see Figure

Page 25

Fireplace

Installation

Continued

Installing Optional Wireless hand-held REMOTE CONTROL for millivolt Egnition - HRC100 and HRC200 Series

NOTICE: Use only alkaline bat- teries (not included).

Installing Remote Receiver

1.Open bottom louver and locate the switch bracket on the right

2.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt alkaline battery (not included) through the clip

3.Attach the terminal wires to the battery. (see Figure 44).

4.Connect wires from receiver to TH and TPTH to control valve (see Figure 43, page 24).

5.Locate the two plastic mounting clips provided with the kit.

6.Use the clips to mount the receiver on remote mounting bracket as shown in Figure 45.

Receiver

9-Volt Alkaline Battery

Terminal

Wires

Battery Clip

Figure 44 - Attaching Alkaline Battery to

Receiver

Plastic Mounting Clips

REMOTE ON OFF

Towards Front

Remote Receiver

Figure 45 - Mountinig Remote Receiver

to Bracket

Installing 9-Volt Alkaline Battery in Hand-

Held Remote Control Unit

1. Remove battery cover on back of remote control unit.

2. Attach terminal wires to a 9-volt alkaline battery (not included). Place battery into the battery housing.

3. Replace battery cover onto remote control unit.

Battery Cover Remote Control Unit

Terminal

Wires

9-Volt

Battery

Housing

Battery

 

Figure 46 - Installing Battery in Hand-

Held Remote Control Unit

Installing Optional Wireless hand-held REMOTE CONTROL for Electronic Egnition

Installing and Activating the Remote

Receiver

1.Open bottom louver and locate the plug recep- tacle. The plug receptacle is located either on the right or left side of cabinet.

2.The WRC model receiver does not require a bat- tery. The receiver can be installed by first plug- ging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 47).

3.Activate the remote handset battery by re- moving the insulating tab on the back of the handset (see Figure 48, page 26). The battery is included pre-installed.

Fireplace

Remote

Control

Receptacle

Receiver

Extension

 

Cord

 

Ignition

 

Module Plug

 

Figure 47 - Connecting WRC Remote

Control Electronic

116035-01E

www.desatech.com

25

Image 25
Contents VCD36RN, VCD36RNE Natural GAS ModelsPROPANE/LP GAS ModelS PROPANE/LP GAS Models VCD36TN, VCD36TNETable of Contents Safety Information High traffic areas Product IdentificationPre-Installation Preparation Product FeaturesLocal Codes Location and space requirementsClearances Packaging and RemovalMantel Clearances Framing and finishingSide Clearances for Combustible Materials Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsLocation of the fireplace Installation PlanningFeet. Use wall straps for this purpose Twisting, bending, etcInstalling Siding Standoff Combustible Exterior Wall Wall Firestop Installing Inner Wall FirestopHorizontal Termination Venting InstallationSnorkel 45 and 30 Offset with Wall Strap Installation for vertical terminationConnect a section of pipe and extend up through the hole Flat Ceiling InstallationTwist-lock the vent cap onto the last section of vent pipe Vertical Venting Vertical Termination Configurations for Rear VentHigh Wind Termination Vertical Termination Configurations for Top VentDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsInstalling optional blower accessories Fireplace InstallationModel BK Installation Electrical Supply ConnectionBlower Model BK Plug in blower power cordPlug in blower power cord to duplex outlet Model BKT InstallationWiring Diagrams Attach the terminal wires to the battery. see Figure Installing Remote ReceiverInstalling and Activating the Remote Receiver Locate the two plastic mounting clips provided with the kitInstalling Gas Piping to Fireplace Location High Altitude installationImportant Fireplaces when factory equipped for use at high Installation Items NeededPropane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemTest Pressures Equal To or Less Than Psig 3.5 kPa Close equipment shutoff valve see FigureRemoving Lower Louver Access Panel Pressure Testing Fireplace Gas ConnectionsRemoving/Replacing Glass Door Removing Top Louver Trim PanelRemoving Glass Door Installing LOGS, lava rock and glowing embersOperating Fireplace Millivolt For your safety Read before lightingLighting Instructions Open the bag of ember materialsTo Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held Remote OperationThermostat Series Model HRC200 Electronic ingnition For your safety Read before lighting Operating optional blower accessoryOperating optional GWMT1 Wall Mounted Thermostat Pilot Optional Wireless Remote OperationIf you pilot assembly does not meet these require- ments Pilot assemblyInspecting Burners Burner Flame PatternGlass Door Cleaning MaintenancePilot and burners Observed Problem Possible Cause Remedy TroubleshootingLogs Venting systemProblem could be caused by When ignitor button is pressedBurner orifice clogged Clean burner see Cleaning Is lit Turn on gas supply or openOr shut off Service person Remote does not function When burner is lit HI position when burner isTery is power is low Operation Processes and logs curing Hours of operationStatement above Electronic Ignition Statement at top Gas leak. See WarningService Hints Replacement PartsTechnical Service SpecificationsPROPANE/NATURAL GAS AccessoriesManual Blower KIT BK Thermostatically Controlled Blower KIT BKTIllustrated Parts Breakdown Parts List Illustrated parts breakdown Washer, Flat 7/8 ID x 2 OD x 1/8 Thick Illustrated Parts Breakdown CD36TNEV Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.