Desa CGCDV42NR, CGCDV42PR, (V)VC42P installation manual Ground Floor Installation, Round Termination

Page 12

Venting Installation

instructions

Continued

 

Minimum Pipe

Siding Standoff

Overlap 11/4"

 

Direct-Vent

 

Pipe

Screws

 

 

Wall

 

 

 

 

 

 

Firestop

 

 

 

Maintain 1"

 

 

 

 

Minimum Air

 

 

 

High Wind

Space Around

 

 

Outer Pipe When

Termination

Penetrating a Wall

Apply Mastic

 

 

 

 

 

 

 

 

 

 

 

 

to Outside

10

3

/ " x 10

3

/

"

Edge of

 

 

4

 

4

 

Standoff

Framed Opening

 

 

 

 

Exterior Wall with Vinyl Siding

Figure 13 - Typical Horizontal Termination Cap Mounting with Additional Siding Standoff Installed

Horizontal Termination Configurations Figures 14 through 18 show different configura- tions and alternatives for venting with horizontal termination. Each figure includes a chart with critical minimum and maximum dimensions which MUST be met. IMPORTANT: If using a venting configuration of only horizontal venting with no vertical run, a 1/4" rise for every 12" of run toward the termination is required.

NOTICE: Do not seal termination cap to vent pipe. Cap must be removable for vent inspection and maintenance.

WARNING: Never run vent downward as this may cause excessive temperatures which could cause a fire. Operation of improperly installed and main- tained venting system could result in serious injury, property damage or loss of life.

GROUND FLOOR INSTALLATION

Recommended Applications:

Installation using cabinet surrounds

Through the wall using round or square termina- tion (up to 12" horizontal pipe)

NOT FOR CORNER INSTALLATION

Adjustable

Horizontal Pipe 12" Max. 45° Elbow

High Wind

Square

Termination

Wall Firestop

Square Termination

Vertical (V)

 

 

Horizontal (H)

32 3/4" min.

 

 

17" max.

45° Elbow

Exterior

Portion of Wall

 

 

 

Wall

Firestop (Round

Termination Only)

Firestop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal

Round

Termination

Round

Termination

*If installing this fireplace at altitudes of 4000 feet and above, it is recommended that an additional vertical height of 6" be added to the vent system.

Figure 14 - Horizontal Termination Configuration for Square or Round Terminations

12

www.desatech.com

116236-01G

Image 12
Contents What to do if YOU Smell GAS Patent PendingTable of Contents Safety InformationSafety Information Product Identification Local CodesHigh traffic areas Product Features Pre-Installation PreparationLocation and space requirements This fireplace does not require electricity to operateClearances Minimum clearances to combustibles for42 1067 mm Front 36 914 mm Top of Standoffs VentFraming and finishing Noncombustible mantels at any height aboveFireplace Location of Termination Cap Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Round TerminationCorner Installation Recommended Applications Corner ground floor installationHorizontal System Installation Using TWO 90 Elbows Installation for vertical termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe High Altitude Installation Vertical VentingParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionFireplace Installation Installing optional blower accessoriesModel BK Installation Plug in blower power cordModel BKT Installation Blower Model BKTInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Connecting Fireplace to GAS Supply Propane/LP FromChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPaPressure Testing Fireplace Gas Connections Installing Remote ReceiverReplace battery cover onto remote control unit Removing/Replacing Glass DoorRemoving Louver Panels Removing Glass DoorInstalling lava rock and glowing embers Installing Brick liner Models BL42DASA and BL42DHASAReplace screen/rod assembly by reversing step Cleaning Glass DoorFor your safety Read before lighting Operating FireplaceLighting Instructions Close top and bottom louversTo Turn OFF GAS To Appliance Manual Lighting Procedure Optional Hand-HeldRemote Operation On/Off Series Model HRC100 Thermostat Series Model HRC200Operating optional blower accessory Pilot assemblyKey Pad Lock Feature Inspecting BurnersCleaning Maintenance Burner Flame PatternGlass Door Pilot and burners LogsVenting system Troubleshooting Observed Problem Possible Cause RemedyProblem could be caused by Replace pilot assembly Burner orifice clogged Clean burner see Cleaning Is litAfter pilot lights, keep gas Long enough Control knob pressedWhen burner is lit HI position when burner is Tery power is lowTurning gas control knob to Cold Minute Air in gas line Operate burner until air isGas leak. See Warning Statement aboveReplacement Parts Service HintsTechnical Service SpecificationsIllustrated Parts Breakdown Parts List 19 18 116236-01G Burner Pan Assembly Accessories Wall mounted on/off switch Wall mounted thermostat control kit gwmt1GwmS2 Not Shown Warranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace