Desa CGCDV42NR, CGCDV42PR, (V)VC42P installation manual Parts List

Page 39

PARTS LIST

Models VC42N, VVC42N, VC42P, VVC42P, cgcDV42nr and cgcDV42pr Series

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 37 of this manual.

KEY PART

 

NO. NUMBER DESCRIPTION

QTY.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

**

Firebox Assembly

**

Face Weldment

108328-01

Door Assembly

108328-02

Door Assembly (V Models Only)

108331-01

Top Louver Assembly

108331-02

Bottom Louver Assembly

**

Fireplace Top

**

Fireplace Top Insulation

**

Fireplace Surround

109082-01

Heat Shield

116216-01

Log Set with Grate Assembly

116338-01

Right Burner Log

116339-01

Left Burner Log

See Below

Left Refractory Brick Panel

See Below

Rear Refractory Brick Panel

See Below

Right Refractory Brick Panel

108455-01

Screen Rod

107840-01

Screen

11418

Push-On Nut

14123

Strain Relief

21171

Gas Knock-Out Cover

24353

Handy Box Assembly

24460

Gas Conduit Assembly

116211-01

Burner Assembly (Natural Gas) (See page 40)

116211-02

Burner Assembly (Propane/LP Gas) (See page 40)

116211-05

Burner Assembly for High Altitude Models (See page 40)

116375-01

Plenum

 

PARTS AVAILABLE - NOT SHOWN

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

1

2

1

1

1

1

1

1

25487

Lava Rock/Bag Assy

27253

Notice Label

 

55240

Vent Label

 

116388-01 Grate Finial

 

** Not a field replaceable part.

 

 

 

REFRACTORY BRICK PANELS

CGCDV42NR

 

 

CGCDV42PR

 

 

VC42NB

VVC42NB

VC42NH

VVC42NH

VVC42PB

VC42PB VVC42NB-HA

VC42PH

VVC42PH DESCRIPTION

1

1

1

2

QTY

111299-02 111299-01

111297-02 111297-01

111298-02 111298-01

111302-02 111302-01 Left Refractory Brick Panel

111300-02 111300-01 Rear Refractory Brick Panel 111301-02 111301-01 Right Refractory Brick Panel

1

1

1

116236-01G

www.desatech.com

39

Image 39
Contents Patent Pending What to do if YOU Smell GASSafety Information Table of ContentsSafety Information Product Identification Local CodesHigh traffic areas This fireplace does not require electricity to operate Product FeaturesPre-Installation Preparation Location and space requirementsFront 36 914 mm Top of Standoffs Vent ClearancesMinimum clearances to combustibles for 42 1067 mmFraming and finishing Noncombustible mantels at any height aboveFireplace Balcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Round Termination Ground Floor InstallationRecommended Applications Corner ground floor installation Corner InstallationHorizontal System Installation Using TWO 90 Elbows Installation for vertical termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsPlug in blower power cord Fireplace InstallationInstalling optional blower accessories Model BK InstallationBlower Model BKT Model BKT InstallationInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Propane/LP From Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Checking GAS ConnectionsInstalling Remote Receiver Pressure Testing Fireplace Gas ConnectionsRemoving Glass Door Replace battery cover onto remote control unitRemoving/Replacing Glass Door Removing Louver PanelsCleaning Glass Door Installing lava rock and glowing embersInstalling Brick liner Models BL42DASA and BL42DHASA Replace screen/rod assembly by reversing stepClose top and bottom louvers For your safety Read before lightingOperating Fireplace Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting Procedure Optional Hand-HeldRemote Operation Thermostat Series Model HRC200 On/Off Series Model HRC100Inspecting Burners Operating optional blower accessoryPilot assembly Key Pad Lock FeatureCleaning Maintenance Burner Flame PatternGlass Door Pilot and burners LogsVenting system Observed Problem Possible Cause Remedy TroubleshootingLong enough Control knob pressed Problem could be caused by Replace pilot assemblyBurner orifice clogged Clean burner see Cleaning Is lit After pilot lights, keep gasCold Minute Air in gas line Operate burner until air is When burner is lit HI position when burner isTery power is low Turning gas control knob toStatement above Gas leak. See WarningSpecifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Parts List 19 18 116236-01G Burner Pan Assembly Accessories Wall mounted on/off switch Wall mounted thermostat control kit gwmt1GwmS2 Not Shown Warranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace