Safety Information

WARNING: Improper in- stallation, adjustment, al- teration, service or mainte- nance can cause injury or property damage. Refer to this manual for correct in- stallation and operational procedures. For assis- tance or additional infor- mation consult a qualified installer, service agency or the gas supplier.

This appliance may be in- stalled in an aftermarket,* permanently located, manufactured (mobile) home, where not prohib- ited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects or other reproduc- tive harm.

IMPORTANT: Read this owner’s manual carefully and completely beforetryingtoassemble,operate or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.

DANGER: Carbon monoxide

poisoning may lead to death!

www.desatech.com116236-01G

Image 2
Contents What to do if YOU Smell GAS Patent PendingTable of Contents Safety InformationSafety Information High traffic areas Product IdentificationLocal Codes Location and space requirements Product FeaturesPre-Installation Preparation This fireplace does not require electricity to operate42 1067 mm ClearancesMinimum clearances to combustibles for Front 36 914 mm Top of Standoffs VentFireplace Framing and finishingNoncombustible mantels at any height above Location of Termination Cap Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Round TerminationCorner Installation Recommended Applications Corner ground floor installationHorizontal System Installation Using TWO 90 Elbows Connect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe High Altitude Installation Vertical VentingParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionModel BK Installation Fireplace InstallationInstalling optional blower accessories Plug in blower power cordModel BKT Installation Blower Model BKTInstallation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Connecting Fireplace to GAS Supply Propane/LP FromChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPaPressure Testing Fireplace Gas Connections Installing Remote ReceiverRemoving Louver Panels Replace battery cover onto remote control unitRemoving/Replacing Glass Door Removing Glass DoorReplace screen/rod assembly by reversing step Installing lava rock and glowing embersInstalling Brick liner Models BL42DASA and BL42DHASA Cleaning Glass DoorLighting Instructions For your safety Read before lightingOperating Fireplace Close top and bottom louversRemote Operation To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held On/Off Series Model HRC100 Thermostat Series Model HRC200Key Pad Lock Feature Operating optional blower accessoryPilot assembly Inspecting BurnersGlass Door Cleaning MaintenanceBurner Flame Pattern Venting system Pilot and burnersLogs Troubleshooting Observed Problem Possible Cause RemedyAfter pilot lights, keep gas Problem could be caused by Replace pilot assemblyBurner orifice clogged Clean burner see Cleaning Is lit Long enough Control knob pressedTurning gas control knob to When burner is lit HI position when burner isTery power is low Cold Minute Air in gas line Operate burner until air isGas leak. See Warning Statement aboveTechnical Service Replacement PartsService Hints SpecificationsIllustrated Parts Breakdown Parts List 19 18 116236-01G Burner Pan Assembly Accessories GwmS2 Not Shown Wall mounted on/off switchWall mounted thermostat control kit gwmt1 Limited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty