Desa CGCDV42PR Fireplace Installation, Check GAS Type, Installing optional blower accessories

Page 19

Fireplace

Installation

CHECK GAS TYPE

Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type or to purchase gas conversion kit (see Accessories, page 42).

Installing optional blower accessories

NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas sup- ply and disconnect heater from gas supply. Contact a qualified service person to do this.

WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury.

Model BK Installation

Follow all instructions provided in the blower accessory kit.

1.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade ter- minals on the blower motor (see Figure 26).

2.Attach green ground wire from power cord to blower housing using screw provided (see Figure 26). Tighten screws securely.

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 26).

4.Be certain that all wire terminals are securely attached to terminals on blower motor and that the screw retaining the green ground wire is tight.

5.Mount speed control box to switch bracket by placing the plastic control shaft forward through the round opening in the switch bracket (see Figure 27).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob pro- vided on shaft.

7.Turn on power to duplex outlet if previously turned off per the warning in column 1.

8.Plug in blower power cord.

a.If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox.

b.If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox owner’s manual for instructions on wiring the duplex outlet.

Lower Firebox

Cavity

Side View

Blower Location

Spade

Magnetic

Terminals

Strips

 

Green

Ground

Wire Screw Exhaust Port

Figure 26 - Blower Model BK

Switch

Bracket Speed Control Control Shaft

 

Blower

 

Plug-In

 

Duplex Outlet (Located

Control Locknut

underneath firebox

floor against lower right

Knob

outside wall)

Figure 27 - Attaching Speed Control to

Firebox

116236-01G

www.desatech.com

19

Image 19
Contents Patent Pending What to do if YOU Smell GASSafety Information Table of ContentsSafety Information Local Codes Product IdentificationHigh traffic areas This fireplace does not require electricity to operate Product FeaturesPre-Installation Preparation Location and space requirementsFront 36 914 mm Top of Standoffs Vent ClearancesMinimum clearances to combustibles for 42 1067 mmNoncombustible mantels at any height above Framing and finishingFireplace Balcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Round Termination Ground Floor InstallationRecommended Applications Corner ground floor installation Corner InstallationHorizontal System Installation Using TWO 90 Elbows Flat Ceiling Installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsPlug in blower power cord Fireplace InstallationInstalling optional blower accessories Model BK InstallationBlower Model BKT Model BKT InstallationBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Propane/LP From Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Checking GAS ConnectionsInstalling Remote Receiver Pressure Testing Fireplace Gas ConnectionsRemoving Glass Door Replace battery cover onto remote control unitRemoving/Replacing Glass Door Removing Louver PanelsCleaning Glass Door Installing lava rock and glowing embersInstalling Brick liner Models BL42DASA and BL42DHASA Replace screen/rod assembly by reversing stepClose top and bottom louvers For your safety Read before lightingOperating Fireplace Lighting InstructionsOptional Hand-Held To Turn OFF GAS To Appliance Manual Lighting ProcedureRemote Operation Thermostat Series Model HRC200 On/Off Series Model HRC100Inspecting Burners Operating optional blower accessoryPilot assembly Key Pad Lock FeatureBurner Flame Pattern Cleaning MaintenanceGlass Door Logs Pilot and burnersVenting system Observed Problem Possible Cause Remedy TroubleshootingLong enough Control knob pressed Problem could be caused by Replace pilot assemblyBurner orifice clogged Clean burner see Cleaning Is lit After pilot lights, keep gasCold Minute Air in gas line Operate burner until air is When burner is lit HI position when burner isTery power is low Turning gas control knob toStatement above Gas leak. See WarningSpecifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Parts List 19 18 116236-01G Burner Pan Assembly Accessories Wall mounted thermostat control kit gwmt1 Wall mounted on/off switchGwmS2 Not Shown Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace