Desa CGCDV42PR To Turn OFF GAS To Appliance Manual Lighting Procedure, Optional Hand-Held

Page 28

OPERATIng fireplace

Continued

7.Turn gas control knob counterclockwise to PILOT (see Figure 45).

8.Push in gas control knob all the way and hold. Immediately light the pilot by repeat- edly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to OFF and call your service technician or gas supplier.

9.Turn on all electric power to the fireplace.

10.Turn gas control knob counterclockwise to ON.

11.This valve is equipped with a HI/LO fea- ture. Set fireplace input as desired.

12.Close lower louver panel.

Gas Control

 

Variable Control Knob

Knob

 

 

 

PILOT

IH

F

F

 

 

O

O

 

 

 

N

 

 

LO

Piezo Ignitor

Figure 45 - Control Valve

TO TURN OFF GAS

TO APPLIANCE

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/Replacing Glass Door, page 25).

2.Follow steps 1 through 8 under Lighting Instructions, page 27.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release gas control knob. Follow steps 9 through 12 under Lighting Instructions.

5.Replace glass door (see Removing/Replacing Glass Door, page 25).

optional Hand-Held

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 42). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions, page 27.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere be- tween HI and LO. Slide the selector switch to the REMOTE position (see Figure 46). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

1.Open lower louver panel.

2.Set selector switch in the OFF position to prevent draining battery.

3.Turn off all electrical power to the appliance if service is to be performed.

4.Push in gas control knob slightly and turn

clockwise to OFF.

5. Close lower louver panel.

Shutting Off Burners Only (pilot stays lit) You may shut off the burners and keep the pilot lit by doing one of the following:

Blower Control Knob (Optional Accessory)

OFF ON

REMOTE

OFF

ON

Selector Switch in Remote Position

Variable

Control Knob

N

 

 

O

 

L

 

T

 

O

I

O

 

O

H

L

 

 

I

F

 

 

P F

 

 

 

 

 

Gas Control Knob in ON Position

1. Turn gas control knob clockwise to the PILOT position.

2. Set selector switch in the OFF position.

Figure 46 - Setting the Selector Switch,

Gas Control Knob and Variable Control

Knob for Remote Operation

28

www.desatech.com

116236-01G

Image 28
Contents What to do if YOU Smell GAS Patent PendingTable of Contents Safety InformationSafety Information Local Codes Product IdentificationHigh traffic areas Product Features Pre-Installation PreparationLocation and space requirements This fireplace does not require electricity to operateClearances Minimum clearances to combustibles for42 1067 mm Front 36 914 mm Top of Standoffs VentNoncombustible mantels at any height above Framing and finishingFireplace Location of Termination Cap Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Round TerminationCorner Installation Recommended Applications Corner ground floor installationHorizontal System Installation Using TWO 90 Elbows Flat Ceiling Installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe High Altitude Installation Vertical VentingParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionFireplace Installation Installing optional blower accessoriesModel BK Installation Plug in blower power cordModel BKT Installation Blower Model BKTBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS Supply Propane/LP FromChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPaPressure Testing Fireplace Gas Connections Installing Remote ReceiverReplace battery cover onto remote control unit Removing/Replacing Glass DoorRemoving Louver Panels Removing Glass DoorInstalling lava rock and glowing embers Installing Brick liner Models BL42DASA and BL42DHASAReplace screen/rod assembly by reversing step Cleaning Glass DoorFor your safety Read before lighting Operating FireplaceLighting Instructions Close top and bottom louversOptional Hand-Held To Turn OFF GAS To Appliance Manual Lighting ProcedureRemote Operation On/Off Series Model HRC100 Thermostat Series Model HRC200Operating optional blower accessory Pilot assemblyKey Pad Lock Feature Inspecting BurnersBurner Flame Pattern Cleaning MaintenanceGlass Door Logs Pilot and burnersVenting system Troubleshooting Observed Problem Possible Cause RemedyProblem could be caused by Replace pilot assembly Burner orifice clogged Clean burner see Cleaning Is litAfter pilot lights, keep gas Long enough Control knob pressedWhen burner is lit HI position when burner is Tery power is lowTurning gas control knob to Cold Minute Air in gas line Operate burner until air isGas leak. See Warning Statement aboveReplacement Parts Service HintsTechnical Service SpecificationsIllustrated Parts Breakdown Parts List 19 18 116236-01G Burner Pan Assembly Accessories Wall mounted thermostat control kit gwmt1 Wall mounted on/off switchGwmS2 Not Shown Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace